Model Number
350D02
SHEAR ICP® SHOCK ACCELEROMETER
Revision: D
ECN #: 48057
Performance
ENGLISH
SI
Sensitivity(± 30 %)
0.1 mV/g
0.01 mV/(m/s²)
Measurement Range
± 50,000 g pk
± 490,000 m/s² pk
Frequency Range(± 1 dB)
4 to 10,000 Hz
4 to 10,000 Hz
Frequency Range
(-3 dB)
2 to 25,000 Hz
2 to 25,000 Hz
[3]
Electrical Filter Corner Frequency(-3 dB)
17 kHz
17 kHz
[1][4]
Mechanical Filter Resonant Frequency
35 kHz
35 kHz
[1][5]
Resonant Frequency
≥
100 kHz
≥
100 kHz
Broadband Resolution(1 to 10,000 Hz)
0.5 g rms
4.9 m/s² rms
[1]
Non-Linearity(per 10,000 g (98,100 m/s²))
≤
2.5 %
≤
2.5 %
Transverse Sensitivity
≤
7 %
≤
7 %
Environmental
Overload Limit(Shock)
± 150,000 g pk
± 1,471,500 m/s² pk
Temperature Range(Operating)
-10 to +150 °F
-23 to +66 °C
Temperature Range
(Storage)
-40 to +200 °F
-40 to +93 °C
Temperature Response
See Graph
See Graph
[1][2]
Electrical
Excitation Voltage
20 to 30 VDC
20 to 30 VDC
Constant Current Excitation
2 to 20 mA
2 to 20 mA
Output Impedance
≤
200 Ohm
≤
200 Ohm
Output Bias Voltage
8 to 14 VDC
8 to 14 VDC
Discharge Time Constant
0.10 sec
0.10 sec
[1]
Settling Time(within 10% of bias)
<1 sec
<1 sec
Electrical Isolation(Case)
>1,000,000 Ohm
>1,000,000 Ohm
Physical
Sensing Element
Ceramic
Ceramic
Sensing Geometry
Shear
Shear
Housing Material
Titanium
Titanium
Sealing
Hermetic
Hermetic
Size (Hex x Height)
0.375 in x 0.87 in
9.5 mm x 22.1 mm
Weight(without cable)
0.16 oz
4.5 gm
[1]
Electrical Connector
Integral Cable
Integral Cable
Cable Length
10 ft
3.05 m
Cable Type
031 Twisted Pair
031 Twisted Pair
Mounting Thread
1/4-28 Male
1/4-28 Male
[6]
All specifications are at room temperature unless otherwise specified.
In the interest of constant product improvement, we reserve the right to change specifications without notice.
ICP
®
is a registered trademark of PCB Group, Inc.
OPTIONAL VERSIONS
Optional versions have identical specifications and accessories as listed for the standard model
except where noted below. More than one option may be used.
M
- Metric Mount
Mounting Thread
M6 x 0.75 Male
M6 x 0.75 Male
NOTES:
[1] Typical.
[2] Test conducted on shaker at 100Hz.
[3] Typical corner frequency for coupled electrical and mechanical filters.
[4] Electrical filter is a second order filter.
[5] Amplitude at resonance is +9 dB.
[6] See PCB Declaration of Conformance PS135 for details.
SUPPLIED ACCESSORIES:
Model ACS-14 High G shock accelerometer calibration using Hopkinson bar. (1)
Model ACS-22 NIST Traceable frequency response (100Hz to ±1 dB point) (1)
Entered: LK
Engineer: RB
Sales: RWM
Approved: BAM
Spec Number:
Date: 4/3/2018
Date: 4/3/2018
Date: 4/3/2018
Date: 4/3/2018
52264
3425 Walden Avenue, Depew, NY 14043
Phone: 716-684-0001
Fax: 716-684-0987
E-Mail: [email protected]