background image

Model Number

M1403-03ADB

FATIGUE RATED LOW PROFILE LOAD CELL, DUAL BRIDGE, METRIC

Revision: NR
ECN #: 43174

Performance

ENGLISH

SI 

Measurement Range(100 x 10^6 cycles)

1011 lbf

4500 N

[5][6]

Sensitivity(± 10 %)

2.0 mV/V

2.0 mV/V

[7][1]

Non-Linearity

≤ 0.04 % FS

≤ 0.04 % FS

Hysteresis

≤ 0.04 % FS

≤ 0.04 % FS

Non-Repeatability

≤ 0.02 %RO

≤ 0.02 %RO

Eccentric Load Sensitivity

0.1 %/in

0.1 %/25.4mm

Resonant Frequency

10 kHz

10 kHz

Side Load Sensitivity

0.1 %/in

0.1 %/25.4mm

Creep(in 20 minutes)

0.025 %

0.025 %

Static Error Band

≤ 0.04 % FS

≤ 0.04 % FS

[5]

Environmental

Overload Limit

3033 lbf

13.5 kN

Load Limit(Side Force, F

X

 or F

Y

)

1011 lb

4500 N

[3]

Load Limit

(Bending Moment, M

X

 or M

Y

)

1011 in-lb

114 Nm

[3]

Load Limit

(Axial Torque, M

Z

)

1011 in-lb

114 Nm

[3]

Temperature Range(Operating)

-65 to +200 °F

-54 to +93 °C

Temperature Range

(Compensated)

+15 to +115 °F

-9 to +46 °C

Temperature Effect on Output(Maximum)

± 0.0008 %Reading/°F

± 0.0018 %Reading/°C

[4]

Temperature Effect on Zero Balance(Maximum)

± 0.0008 %FS/°F

± 0.0018 %FS/°C

[4]

Electrical

Bridge Resistance

350 Ohm

350 Ohm

[1]

Excitation Voltage(Recommended)

10 VDC

10 VDC

[2]

Insulation Resistance

>5k GOhm

>5k GOhm

Zero Balance

≤ 1 %RO

≤ 1 %RO

Output Polarity

+Tension

+Tension

Physical

Size (Diameter x Height)

4.12 in x 2.50 in

104.60 mm x 63.50 mm

[8]

Weight

6.4 lb

2.9 kg

Mounting Thread

No English Equivalent

M16 x 2.0

Sensing Element

Strain Gage

Strain Gage

Mounting Torque

200 in-lb

23 Nm

Deflection at Full Scale Capacity

0.001 in

0.03 mm

Electrical Connector

PT02E-10-6P (2)

PT02E-10-6P (2)

All specifications are at room temperature unless otherwise specified.
In the interest of constant product improvement, we reserve the right to change specifications without notice.

NOTES:

[1]Nominal.
[2]Calibrated at 10 VDC, usable 5 to 20 VDC or VAC RMS.
[3]Singularly applied, i.e. no other extraneous loads.
[4]Over compensated operating temperature range.
[5]FS - Full Scale.
[6]Calibrated in tension and compression.
[7]RO - Rated Output.
[8]See Outline Drawing 49605 for Complete Dimensions

SUPPLIED ACCESSORIES: 

Model 084A90 Connector Shroud (2)

OPTIONAL ACCESSORIES: 

Model 181-012A PT06A-10-6S(SR)
Model 8311-01-10A CABLE

PCB Load & Torque, Inc.
24350 Indoplex Circle
Farmington Hills, MI 48335
UNITED STATES
Phone: 866-684-7107
Fax: 716-684-0987
E-Mail: [email protected]
Web site: 
http://www.pcbloadtorque.com

OPTIONAL VERSIONS

Optional versions have identical specifications and accessories as listed for the standard 

model except where noted below. More than one option may be used.

Entered: AP

Engineer: PE

Sales: RM

Approved: JSD

Spec Number:

Date: 1/12/2015

Date: 1/12/2015

Date: 1/12/2015

Date: 1/12/2015

59474 

Summary of Contents for M1403-03ADB

Page 1: ...D CELL DUAL BRIDGE METRIC Installation and Operating Manual For assistance with the operation of this product contact PCB Piezotronics Inc Toll free 800 828 8840 24 hour SensorLine 716 684 0001 Fax 71...

Page 2: ...ty regimen When in doubt about a calibration cycle a good rule of thumb is to recalibrate on an annual basis It is also good practice to recalibrate after exposure to any severe temperature extreme sh...

Page 3: ...rchase Order should include authorization to proceed and return at current pricing which can be obtained from a factory customer service representative Contact Information International customers shou...

Page 4: ...isclosure Table Pb Hg Cd Cr VI PBB PBDE O O O O O O PCB X O O O O O O O O O O O X O O O O O O O O O O O O O O O O O O O O O O O O O X O O O O O O O O O X O O O O O O O O O O O X O O O O O X O O O O O...

Page 5: ...e O O X O O O Wires O O O O O O Cables X O O O O O Plastic O O O O O O Solder X O O O O O Copper Alloy Brass X O O O O O This table is prepared in accordance with the provisions of SJ T 11364 O Indica...

Page 6: ...LECTRICAL INSTALLATION 5 5 1 Electrical Drawing Western Regional Std 5 5 2 Cable Grounding Considerations 5 6 0 CALIBRATION 5 6 1 Calibration Certificate Description 5 6 1 1 Measured Output 6 6 1 2 Hy...

Page 7: ...the parts under test have completed the planned fatigue test cycles 3 0 OVERVIEW Dual bridge fatigue rated load cells are specifically designed for repetitive testing Applications include material te...

Page 8: ...ote that the performance of the load cell may be affected if the factory installed mounting base is removed or modified 4 2 Mounting Load Cell to a Standard Base or Custom Fixture If the load cell is...

Page 9: ...ctor Protector 1 Remove the 4 40 x 1 4 button head cap screws from the connector using a 1 16 hex wrench as shown in Figure 7 2 Carefully pull the connector from the load cell Take care to not break o...

Page 10: ...wiring may result in unstable or noisy signals A simple test with a voltmeter connected between the power cord ground and the structure on which the load cell is mounted can confirm that the structur...

Page 11: ...s are adjusted such that the error due to eccentric loading is less than 0 1 per inch of offset Side loads moments and torque must be limited to avoid electrical or mechanical damage to the load cell...

Page 12: ...tion certificate and adjust the span or gain until the display reads the force value stated on the certificate 4 Repeat steps 1 3 to verify that a valid calibration setting has been obtained 5 If poss...

Page 13: ...ridge resistances A D excitation and B C the signal leads 9 Check bridge balance 10 Keep a record of your observations correct problems or contact PCB factory for assistance 11 2 1 Estimating Bridge B...

Page 14: ...factory for any reason For calibration services if possible a copy of the purchase order covering the requested services should be included with the returned load cell 13 0 WARRANTY Standard warranty...

Page 15: ...in x 2 50 in 104 60 mm x 63 50 mm 8 Weight 6 4 lb 2 9 kg Mounting Thread No English Equivalent M16 x 2 0 Sensing Element Strain Gage Strain Gage Mounting Torque 200 in lb 23 Nm Deflection at Full Sca...

Page 16: ...LOAD CELLS 5 8 18UNF 3B METRIC M LOAD CELLS M16X2 0 4H SPECIAL LOAD CELL 1 14UNS 3B 2 50 63 5 030 76 45 THREAD x 88 22 3 STANDARD LOAD CELLS 5 8 18 UNF 3B METRIC M LOAD CELLS M16 X 2 0 4H SPECIAL LOA...

Reviews: