PCB Piezotronics M108A02 Installation And Operating Manual Download Page 10

 

Drawing Number: 21113 
Revision: A 

 

OPERATION MANUAL FOR 

ICP

®

 HIGH PRESSURE SENSORS 

Series 108 & 109 

5.0 

OPERATION

 

 

Select  desired  mode  of  circuit  connection  and  turn 
power unit on. 

 

Observe fault monitor meter at the front panel of the 
power unit. 

 

Normal  operation  is  indicated  by  an  approximate 
midscale  reading.    Shorted  cable  or  connections  are 
indicated by a zero reading (red area). 

 

Open  cable  or  connections  are  indicated  by  a  full- 
scale (yellow area) reading. 

 

Allow  instrument  several  minutes  to  warm  up  and 
thermally stabilize. 

 

When  output  from  the  power  unit  is  connected  to 
readout  equipment,  a  drift  in  the  voltage  signal  will 
be noticed; this is normal.  This voltage signal drift is 
caused  by  the  charging  of  the  coupling  capacitor  in 
the power unit and will cease within several minutes. 
 

6.0 

POLARITY 

 

The  108  &  109  Series  are  designed  to  produce  a 
positive  output  voltage  for  increasing  pressure  at  the 
diaphragm. 
 

7.0 

MAINTENANCE

 

 

The  small  size  and  sealed  construction  of  the  108  & 
109  Series  precludes  field  maintenance  and  repair.  
Contact the factory for further assistance. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
ICP

®

 is a registered trademark of PCB Piezotronics 

Summary of Contents for M108A02

Page 1: ...10k psi 0 5 mV psi long life Installation and Operating Manual For assistance with the operation of this product contact PCB Piezotronics Inc Toll free 800 828 8840 24 hour SensorLine 716 684 0001 Fax...

Page 2: ...alized tests including sensitivity at elevated or cryogenic temperatures phase response extended high or low frequency response extended range leak testing hydrostatic pressure testing and others For...

Page 3: ...tion on particular operating steps The following symbols may be found on the equipment described in this manual This symbol on the unit indicates that high voltage may be present Use standard safety p...

Page 4: ...China RoHS 2 Disclosure Table Pb Hg Cd Cr VI PBB PBDE O O O O O O PCB X O O O O O O O O O O O X O O O O O O O O O O O O O O O O O O O O O O O O O X O O O O O O O O O X O O O O O O O O O O O X O O O O...

Page 5: ...O Wires O O O O O O Cables X O O O O O Plastic O O O O O O Solder X O O O O O Copper Alloy Brass X O O O O O This table is prepared in accordance with the provisions of SJ T 11364 O Indicates that sai...

Page 6: ...f diaphragm give these sensors a high natural frequency and linearity The microelectronic amplifier converts the high impedance voltage from the quartz package into a low impedance high level output s...

Page 7: ...nicks and other imperfections which might cause leaks at high pressures 3 3 RECESSED MOUNT The recessed installation is shown in the Recessed Mount figure This type of mounting protects the sensor dia...

Page 8: ...e of recessed installation In severe pyrotechnic environments sensor life may be severely limited with flush installation 3 5 FLASH TEMPERATURE EFFECTS The ceramic coating on the diaphragm of these se...

Page 9: ...shows the 108 109 Series connected to a PCB Model 484B06 power unit The 484B06 is a power unit that can be AC or DC coupled In the DC couple mode a level shifting circuit removes the bias level and p...

Page 10: ...instrument several minutes to warm up and thermally stabilize When output from the power unit is connected to readout equipment a drift in the voltage signal will be noticed this is normal This volta...

Page 11: ......

Page 12: ......

Reviews: