PAGE 8
TO Option
The TO (Temperature Output) option includes an additional independent 4-20mA output for temperature
measurement. The temperature range is from -40°C to 125°C with an overall accuracy of ±5%FSO. The
imbedded temperature sensor monitors the environment internal to the sensor housing and is situated at
approximately mid level.
Figure 4
– TO wiring
For integral cable sensors:
RED
4-20mA Vibration Positive
BLACK
4-20mA Vibration Negative
GREEN
4-20mA Temperature Negative
WHITE
4-20mA Temperature Positive
Note:
- The same power supply can be used for both 4-20mA loops. Connect both positive terminals directly to the