Taking Measurements 

When measuring the current output from the unit, use the following formula to calculate the vibration level: 

 

Vibration Output = (Measured Output – 4mA) x (Full Scale Vibration Output /16mA) 

 

 

 

Measured 

mA 

642AX0 642AX1 642AX2

 

4.00 

0.0 ips, pk 

0.0 ips, pk 

0.0 ips, pk 

 

8.00 

0.125 ips, pk 

0.25 ips, pk 

0.5 ips, pk 

 

12.0 

0.25 ips, pk 

0.5 ips, pk 

1.0 ips, pk 

 

15.75 

0.37 ips, pk 

0.73 ips, pk 

1.47 ips, pk 

 

20 

0.5 ips, pk 

1.0 ips, pk 

2.0 ips, pk 

 

 

Measured 

mA 

643AX0 643AX1 643AX2

 

4.00 

0.0 ips, rms 

0.0 ips, rms 

0.0 ips, rms 

 

8.00 

0.125 ips, rms 

0.25 ips, rms 

0.5 ips, rms 

 

12.0 

0.25 ips, rms 

0.5 ips, rms 

1.0 ips, rms 

 

15.75 

0.37 ips, rms 

0.73 ips, rms 

1.47 ips, rms 

 

20 

0.5 ips, rms 

1.0 ips, rms 

2.0 ips, rms 

 

 

Measured mA 

647 

648 

 

4.00 

0.0 g rms 

0.0 g rms 

 

 

8.00 

1.25 g rms 

2.50 g rms  

 

12.0 

2.50 g rms 

5.00 g rms 

 

15.75 

3.67 g rms 

7.34 g rms 

 

20 

5.00 g rms 

10.0 g rms  

 

 

 

 

 

PAGE 6 

 

Summary of Contents for IMI SENSORS HT642A02

Page 1: ...ut Velocity Sensor Installation and Operating Manual For assistance with the operation of this product contact PCB Piezotronics Inc Toll free 800 959 4464 24 hour SensorLine 716 684 0001 Fax 716 684 3823 E mail imi pcb com Web www imi sensors com ...

Page 2: ...ity regimen When in doubt about a calibration cycle a good rule of thumb is to recalibrate on an annual basis It is also good practice to recalibrate after exposure to any severe temperature extreme shock load or other environmental influence or prior to any critical test PCB Piezotronics maintains an ISO 9001 certified metrology laboratory and offers calibration services which are accredited by A...

Page 3: ...urchase Order should include authorization to proceed and return at current pricing which can be obtained from a factory customer service representative Contact Information International customers should direct all inquiries to their local distributor or sales office A complete list of distributors and offices can be found at www pcb com Customers within the United States may contact their local s...

Page 4: ... O PCB板 X O O O O O 电气连接器 O O O O O O 压电晶体 X O O O O O 环氧 O O O O O O 铁氟龙 O O O O O O 电子 O O O O O O 厚膜基板 O O X O O O 电线 O O O O O O 电缆 X O O O O O 塑料 O O O O O O 焊接 X O O O O O 铜合金 黄铜 X O O O O O 本表格依据 SJ T 11364 的规定编制 O 表示该有害物质在该部件所有均质材料中的含量均在 GB T 26572 规定的限量要求以下 X 表示该有害物质至少在该部件的某一均质材料中的含量超出 GB T 26572 规定的限量要求 铅是欧洲RoHS指令2011 65 EU附件三和附件四目前由于允许的豁免 CHINA RoHS COMPLIANCE ...

Page 5: ...te O O X O O O Wires O O O O O O Cables X O O O O O Plastic O O O O O O Solder X O O O O O Copper Alloy Brass X O O O O O This table is prepared in accordance with the provisions of SJ T 11364 O Indicates that said hazardous substance contained in all of the homogeneous materials for this part is below the limit requirement of GB T 26572 X Indicates that said hazardous substance contained in at le...

Page 6: ...nsor Operating Guide with Enclosed Warranty Information 3425 Walden Avenue Depew New York 14043 2495 Phone 716 684 0003 Fax 716 684 3823 Toll Free Line 1 800 959 4IMI AND INSTRUMENTATION FOR MACHINE CONDITION MONITORING AND INSTRUMENTATION FOR MACHINE CONDITION MONITORING MANUAL NUMBER 31519 MANUAL REVISION NR ECN NUMBER ...

Page 7: ...Introduction Page 3 General Features Dimension Drawing Page 4 Operation and Wiring Page 5 Standard Wiring Taking Measurements RV Option TO Option Installation Page 9 ESD Sensitivity Page 10 Warranty Servicing Warranty Service Return Procedure Page 11 Customer Service Page 12 PAGE 2 ...

Page 8: ...n sheets for further details General Features Expanded Temperature Range from 40 C to 125 C Imbedded Piezoelectric Accelerometer for improved accuracy and frequency response Vibration range can be in Acceleration or Velocity Allows for continuous vibration monitoring of critical applications Reduces sophisticated vibration analysis requirements RV Raw Vibration option for conducting frequency anal...

Page 9: ...sion Drawing 1 05 26 7 PIN B NEGATIVE 4 20 mA PIN A POSITIVE 4 20 mA 1 8 HEX ALLEN KEY REQUIRED MOUNTING STUD MODEL 080A162 SUPPLIED 1 4 28 UNF 2A 3 4 16 UNF 2A 1 41 35 8 7 8 22 HEX 1 98 45 7 1 24 31 5 ELECTRICAL CONNECTOR 5 8 24 UNEF 2A 2 PIN MIL C 5015 Inch mm PAGE 4 ...

Page 10: ...ve input from the power supply to Pin B or Blue wire of the sensor Figure 1 wiring loop powered Figure 2 wiring loop powered DC source If using a standard DC power supply install either an ammeter and or load resistor in line with the output Pin B or Blue wire The resistor will generate a DC voltage that is proportional to current by V IR If R ohms and I mA then V VDC 500 6 3 Note Resistor value m...

Page 11: ...s pk 0 25 ips pk 0 5 ips pk 12 0 0 25 ips pk 0 5 ips pk 1 0 ips pk 15 75 0 37 ips pk 0 73 ips pk 1 47 ips pk 20 0 5 ips pk 1 0 ips pk 2 0 ips pk Measured mA 643AX0 643AX1 643AX2 4 00 0 0 ips rms 0 0 ips rms 0 0 ips rms 8 00 0 125 ips rms 0 25 ips rms 0 5 ips rms 12 0 0 25 ips rms 0 5 ips rms 1 0 ips rms 15 75 0 37 ips rms 0 73 ips rms 1 47 ips rms 20 0 5 ips rms 1 0 ips rms 2 0 ips rms Measured mA...

Page 12: ...yzers can use this vibration signal for further analysis Figure 3 RV wiring For integral cable sensors RED 4 20mA Positive BLACK 4 20mA Negative same as green GREEN RV Acceleration Negative same as black WHITE RV Acceleration Positive Note The Acceleration Signal Negative has to be isolated from any grounding If this terminal is grounded the 4 20mA loop will short causing no output The acceleratio...

Page 13: ...ure sensor monitors the environment internal to the sensor housing and is situated at approximately mid level Figure 4 TO wiring For integral cable sensors RED 4 20mA Vibration Positive BLACK 4 20mA Vibration Negative GREEN 4 20mA Temperature Negative WHITE 4 20mA Temperature Positive Note The same power supply can be used for both 4 20mA loops Connect the both positive terminals to directly to th...

Page 14: ...SENSORS A Installation ND INSTRUMENTATION FOR MACHINE CONDITION MONITORING Installation should be performed per the following detail drawing for best performance PAGE 9 ...

Page 15: ...ment High voltage electrostatic discharge ESD can damage electrical devices Similar to a capacitor a cable can hold a charge caused by triboelectric transfer such as that which occurs in the following Laying on and moving across a rug Any movement through air The action of rolling out a cable and or Contact with a non grounded person The PCB solution for product safety Connect the cables only with...

Page 16: ...servicing at no charge Before returning the unit please consult a factory IMI applications engineer concerning the situation as certain problems can often be corrected with simple on site procedures Return procedure To expedite returned instrumentation contact a factory IMI applications engineer for a RETURN MATERIAL AUTHORIZATION RMA NUMBER Please have information available such as model and seri...

Page 17: ...ve your purchase price refunded IMI offers to all customers at no charge 24 hour phone support This service makes product or application support available to our customers day or night seven days a week When unforeseen problems or emergency situations arise call the IMI Hot Line at 716 684 0003 and an application specialist will assist you 3425 Walden Avenue Depew NY 14043 2495 Phone 716 684 0003 ...

Page 18: ... we reserve the right tochange specifications without notice ICP is a registeredtrademarkof PCB Piezotronics Inc M Metric Mount SuppliedAccessory Model M080A163A 1 RV BufferedAnalogSignal Output 100 mV g 20 Electrical Connector 3 Pin MIL C 5015 3 Pin MIL C 5015 Electrical Connections 4 20 mA Pos 4 20 mA Pos Electrical Connections 4 20 mA Neg Signal Output Neg 4 20 mA Neg Signal Output Neg Electric...

Page 19: ...DM 10 6 14 ECB 10 6 14 DRK 10 6 14 jmorawski 11 45 10 10 2014 36794 PCB Piezotronics Inc claims proprietary rights in the information disclosed hereon Neither it nor any reproduction thereof will be disclosed to others without the written consent of PCB Piezotronics Inc REVISIONS REV DESCRIPTION DIN A UPDATED NOTE 1 43341 3 4 16 UNF 2A 1 4 28 UNF 2A MOUNTING STUD MODEL 080A162 SUPPLIED 1 FOR METRI...

Page 20: ...LL MOUNTING SURFACES SEE ARROWS FIG 1 2 FIG 2 TIGHTEN THE MOUNTING STUD USING THE ALLEN KEY TORQUE THE MOUNTING STUD TO WITHIN 3 TO 4 FT LBS 4 1 TO 5 4 Nm FIG 3 THREAD THE SENSOR S HEX NUT ONTO THE MOUNTING STUD POSITION THE CABLE OR CONNECTOR TO THE DESIRED LOCATION AND HAND TIGHTEN THE HEX NUT FIG 4 TIGHTEN THE HEX NUT USING A TORQUE WRENCH TO WITHIN 2 TO 3 FT LBS 2 7 TO 4 1 Nm WHILE HOLDING THE...