PAGE 29
SENSO
RS AN
D INS
TRUME
N
TATIO
N F
OR MAC
HINE
CON
DITION M
ONIT
ORIN
G
Unless otherwise specified, the Smart Switch comes from the factory with a set of default parameters. The
specific set of parameters depends on the last alphanumeric character in the model number.
Last Alphanumeric Character
1
2
3
4
X
P
aram
et
er
MAVT™
Enabled
Custom,
Customer-
Specific
Configuration
Alarm Threshold
0.60 ips
Hysteresis
6%
Relay Contacts-
Normal State
Normally
Open
Normally
Closed
Normally
Open
Normally
Closed
Relay Contacts-
Reset State
Latching
Latching
Non-Latching Non-Latching
Power On Delay
3 sec
Operation Delay
6 sec
Startup Delay-
Status
Enabled
Startup Delay-
Time Period
3 sec
Startup Delay-
Startup Alarm Threshold
2x
Startup Delay-
Residual Vibration Level
Dependent
5% of Threshold
Execution of Delays