background image

list(s)  accompanying  the  shipment.  A 
detailed  account  of  the  nature  of  the 
problem(s)  being  experienced  with  the 
equipment  should  also  be  included 
inside  the  package(s)  containing  any 
returned materials.   
 
A  Purchase  Order,  included  with  the 
returned  materials,  will  expedite  the 
turn-around  of  serviced  equipment.  It  is 
recommended  to  include  authorization 
on  the  Purchase  Order  for  PCB  to 
proceed  with  any  repairs,  as  long  as 
they  do  not  exceed  50%  of  the 
replacement  cost  of  the  returned 
item(s).  PCB  will  provide  a  price 
quotation 

or 

replacement 

recommendation  for  any  item  whose 
repair  costs  would  exceed  50%  of 
replacement cost, or any item that is not 
economically  feasible  to  repair.  For 
routine 

calibration 

services, 

the 

Purchase 

Order 

should 

include 

authorization  to  proceed  and  return  at 
current  pricing,  which  can  be  obtained 
from 

factory 

customer 

service 

representative.   
 

Contact  Information 

–  International 

customers  should  direct  all  inquiries  to 
their  local  distributor  or  sales  office.  A 

complete  list  of  distributors  and  offices 
can 

be 

found 

at 

www.pcb.com. 

Customers within the United States may 
contact  their  local  sales  representative 
or 

factory 

customer 

service 

representative.  A  complete  list  of  sales 
representatives 

can 

be 

found 

at 

www.pcb.com. 

Toll-free 

telephone 

numbers  for  a  factory  customer  service 
representative, 

in 

the 

division 

responsible  for  this  product,  can  be 
found on the title page at the front of this 
manual.  Our  ship  to  address  and 
general contact numbers are:   
 
PCB Piezotronics, Inc.  
3425 Walden Ave. 
Depew, NY14043 USA  
Toll-free: (800) 828-8840  
24-hour SensorLine

SM

: (716) 684-0001  

Website: www.pcb.com 

E-mail: [email protected]  
 
 
 
 
 
 
 
 

Summary of Contents for IMI Sensors 685B Series

Page 1: ...celerometer 1 1 5 in sec peak Installation and Operating Manual For assistance with the operation of this product contact PCB Piezotronics Inc Toll free 800 959 4464 24 hour SensorLine 716 684 0001 Fa...

Page 2: ...ty regimen When in doubt about a calibration cycle a good rule of thumb is to recalibrate on an annual basis It is also good practice to recalibrate after exposure to any severe temperature extreme sh...

Page 3: ...rchase Order should include authorization to proceed and return at current pricing which can be obtained from a factory customer service representative Contact Information International customers shou...

Page 4: ...isclosure Table Pb Hg Cd Cr VI PBB PBDE O O O O O O PCB X O O O O O O O O O O O X O O O O O O O O O O O O O O O O O O O O O O O O O X O O O O O O O O O X O O O O O O O O O O O X O O O O O X O O O O O...

Page 5: ...e O O X O O O Wires O O O O O O Cables X O O O O O Plastic O O O O O O Solder X O O O O O Copper Alloy Brass X O O O O O This table is prepared in accordance with the provisions of SJ T 11364 O Indica...

Page 6: ...ORING 685B Series Electronic Vibration Switch Operating Guide with Enclosed Warranty Information 3425 Walden Avenue Depew New York 14043 2495 Phone 716 684 0003 Fax 716 684 3823 Toll Free Line 1 800 9...

Page 7: ...ectromechanical Relays Pin Location Diagram Models with External Accelerometer and Triac Relays Pin Location Diagram Models with External Accelerometer and Electromechanical Relays Configuring the 685...

Page 8: ...accuracy and frequency response Vibration range can be measured in acceleration velocity or displacement factory set Provides dual 5 Amp Triac SPST or 10 Amp Form C SPDT relay outputs Adjustable trip...

Page 9: ...T or 10A 245Vac 5A 30Vdc Form C Relay SPDT Operating Temperature Range 22 to 158 F 30 to 70 C Storage Temperature Range 40 to 257 F 40 to 125 C Relative Humidity NEMA 4X Rating Case Dimension W x H x...

Page 10: ...o options to retrofit existing 3 bolt pattern installations Model 080A209 mounting plate required see optional accessories on page 13 Use grease between all surfaces to insure specified frequency resp...

Page 11: ...PAGE 6 SENSORS AND INSTRUMENTATION FOR MACHINE CONDITION MONITORING Standard Model Dimension Drawing with NPT Conduit Hubs Inch mm...

Page 12: ...ORING Explosion Proof Model Dimension Drawing Inch mm WARNING AC and DC input signals and power supply voltages could be hazardous DO NOT connect live wires to screw terminal plugs and DO NOT insert r...

Page 13: ...ug lightly on the wire to confirm connection is secure Pin Location Diagram Models with Internal Accelerometer and Triac Relays Pin Category Description 1 AC Power Power 2 Power Common 3 Earth Ground...

Page 14: ...ally Closed when dipswitch is in de energized position 5 Common connection 6 Normally Open when dipswitch is in de energized position 7 Alert Output Normally Closed when dipswitch is in de energized p...

Page 15: ...ate inside the top cover The cable shield to the accelerometer should be grounded as required by local codes as well as to limit RFI EMI interference Pin Category Description 1 AC Power Power 2 Power...

Page 16: ...red by local codes as well as to limit RFI EMI interference Pin Category Description 1 AC Power Power 2 Power Common 3 Earth Ground Also connect to enclosure safety lug 4 Alarm Output Normally Closed...

Page 17: ...age of the alarm value is reached Time delays for both functions are controlled using the second and fourth potentiometers Alert and alarm relays can be reset remotely by using the RESET and COMM pins...

Page 18: ...d alarm relays can be reset remotely by using the RESET and COMM pins or by using the internal reset switch as seen on the upper right hand corner of the diagram Using the first dipswitch beneath the...

Page 19: ...imulator repeat step 5 for the Alert signal 8 Adjust the SP Alert set point potentiometer to the point where the yellow Alert LED illuminates It is important to set the Alarm potentiometer first becau...

Page 20: ...PAGE 15 SENSORS AND INSTRUMENTATION FOR MACHINE CONDITION MONITORING Optional Accessories Model 080A209 Adapter Plate To retrofit old style vibration switch bolt patterns...

Page 21: ...INE CONDITION MONITORING Model 699A05 Portable 4 20 mA Calibrator Provides current output for 685B Series testing read out and calibration purposes Also receives and displays current signal from 4 20...

Page 22: ...ischarge ESD can damage electrical devices Similar to a capacitor a cable can hold a charge caused by triboelectric transfer such as that which occurs in the following Laying on and moving across a ru...

Page 23: ...Type two provided 0 Triac 5A 245vac 1 Form C Relay SPDT 10A 245Vac 5A 30Vdc Enclosure Type Hazardous Area Approval A1 Basic enclosure internal pushbutton for remote reset A2 Same as A1 plus external p...

Page 24: ......

Page 25: ......

Reviews: