list(s)  accompanying  the  shipment.  A 
detailed  account  of  the  nature  of  the 
problem(s)  being  experienced  with  the 
equipment  should  also  be  included 
inside  the  package(s)  containing  any 
returned materials.   
 
A  Purchase  Order,  included  with  the 
returned  materials,  will  expedite  the 
turn-around  of  serviced  equipment.  It  is 
recommended  to  include  authorization 
on  the  Purchase  Order  for  PCB  to 
proceed  with  any  repairs,  as  long  as 
they  do  not  exceed  50%  of  the 
replacement  cost  of  the  returned 
item(s).  PCB  will  provide  a  price 
quotation 

or 

replacement 

recommendation  for  any  item  whose 
repair  costs  would  exceed  50%  of 
replacement cost, or any item that is not 
economically  feasible  to  repair.  For 
routine 

calibration 

services, 

the 

Purchase 

Order 

should 

include 

authorization  to  proceed  and  return  at 
current  pricing,  which  can  be  obtained 
from 

factory 

customer 

service 

representative.   
 

Contact  Information 

–  International 

customers  should  direct  all  inquiries  to 
their  local  distributor  or  sales  office.  A 

complete  list  of  distributors  and  offices 
can 

be 

found 

at 

www.pcb.com. 

Customers within the United States may 
contact  their  local  sales  representative 
or 

factory 

customer 

service 

representative.  A  complete  list  of  sales 
representatives 

can 

be 

found 

at 

www.pcb.com. 

Toll-free 

telephone 

numbers  for  a  factory  customer  service 
representative, 

in 

the 

division 

responsible  for  this  product,  can  be 
found on the title page at the front of this 
manual.  Our  ship  to  address  and 
general contact numbers are:   
 
PCB Piezotronics, Inc.  
3425 Walden Ave. 
Depew, NY14043 USA  
Toll-free: (800) 828-8840  
24-hour SensorLine

SM

: (716) 684-0001  

Website: www.pcb.com 

E-mail: [email protected]  
 
 
 
 
 
 
 
 

Summary of Contents for ICP 124A21

Page 1: ...ty regimen When in doubt about a calibration cycle a good rule of thumb is to recalibrate on an annual basis It is also good practice to recalibrate after exposure to any severe temperature extreme sh...

Page 2: ...rchase Order should include authorization to proceed and return at current pricing which can be obtained from a factory customer service representative Contact Information International customers shou...

Page 3: ...isclosure Table Pb Hg Cd Cr VI PBB PBDE O O O O O O PCB X O O O O O O O O O O O X O O O O O O O O O O O O O O O O O O O O O O O O O X O O O O O O O O O X O O O O O O O O O O O X O O O O O X O O O O O...

Page 4: ...e O O X O O O Wires O O O O O O Cables X O O O O O Plastic O O O O O O Solder X O O O O O Copper Alloy Brass X O O O O O This table is prepared in accordance with the provisions of SJ T 11364 O Indica...

Page 5: ...eramic coated tip for protection against erosion by hot gasses when the sensor is flush mounted directly in combustion chambers NOTE The sensor probe in this series is factory installed at a precise d...

Page 6: ...ut voltage must not be higher than 30 volts If it is desired to build a power unit rather than to use one of those available from PCB contact the factory for approval of this change The Models 124A21...

Page 7: ...l Diaphragm Invar Invar Sealing Welded Hermetic Welded Hermetic Electrical Connector 10 32 Coaxial Jack 10 32 Coaxial Jack Weight 4 0 oz 112 gm Water Flow Rate at 50 psi 1 2 gal min 4 5 L min All spec...

Page 8: ...WATER COOLED PRESSURE SENSOR XXX 005 JDM 12 28 18 JDM 12 28 18 MJP 12 28 18 69242 PCB Piezotronics Inc claims proprietary rights in the information disclosed hereon Neither it nor any reproduction the...

Page 9: ...SURE SENSOR XXX 005 JDM 12 28 18 JDM 12 28 18 MJP 12 28 18 SEAL SURFACE MUST BE FLAT AND FREE OF TOOL MARKS WITH AT LEAST A FINISH OF 63 1 6 RECOMMENDED MOUNTING TORQUE 5 10 in lb RECOMMENDED MOUNTING...

Reviews: