PAGE 10 

 

MANUAL NUMBER:  19175 
MANUAL REVISION:  A 

Warranty 

 

PCB instrumentation is warranted against defective material and workmanship for 1 year unless otherwise 

expressly specified.  Damage to instruments caused by incorrect power or misapplication, is not covered by 

warranty.  

If there are any questions regarding power, intended application, or general usage, please consult with 

your local sales contact or distributor.

  Batteries and other expendable hardware items are not covered by 

warranty. 

 
Calibration & Service 

 

Aside from battery replacement, no maintenance is required for this unit.  The 480C02 contains no field 

serviceable parts and is not designed for field repair.  Field repair is typically 

NOT

 recommended and may void 

any warranty.  If factory service is required, return the instrumentation according to the “Return Procedure” stated 

below.  

A repair and/or replacement quotation will be provided prior to servicing at no charge.

  Before returning 

the unit, please consult a factory PCB applications engineer concerning the situation as certain problems can 

often be corrected with simple on-site procedures. 

 

PCB will perform calibrations on model 480C02 on request.  Typical calibration validates the unit functions within 

factory new parameters, includes replacement of batteries and a factory calibration certificate. 

 
Return Procedure 

 

To expedite returned instrumentation, contact a factory PCB applications engineer for a RETURN MATERIAL 

AUTHORIZATION (RMA) NUMBER.

  When requesting the RMA, please be prepared to provide the model 

number, serial number, a brief written description of the problem, your company details, and any other pertinent 

information.  We also recommend a copy of this information should be provided in the package with the 

instrument. 

 

Customers outside the U.S. should consult their local PCB distributor for information on returning equipment.  For 

exceptions, please contact the International Sales department at PCB to request shipping instructions and an 

RMA.  For assistance, please call (716) 684-0003, or fax us at (716) 684-3823.  You may also receive assistance 

via e-mail at 

[email protected]

 or visit our web site at 

www.pcb.com

 

Summary of Contents for 480C02

Page 1: ...l Conditioner Installation and Operating Manual For assistance with the operation of this product contact PCB Piezotronics Inc Toll free 800 828 8840 24 hour SensorLine 716 684 0001 Fax 716 684 0987 E...

Page 2: ...ty regimen When in doubt about a calibration cycle a good rule of thumb is to recalibrate on an annual basis It is also good practice to recalibrate after exposure to any severe temperature extreme sh...

Page 3: ...rchase Order should include authorization to proceed and return at current pricing which can be obtained from a factory customer service representative Contact Information International customers shou...

Page 4: ...isclosure Table Pb Hg Cd Cr VI PBB PBDE O O O O O O PCB X O O O O O O O O O O O X O O O O O O O O O O O O O O O O O O O O O O O O O X O O O O O O O O O X O O O O O O O O O O O X O O O O O X O O O O O...

Page 5: ...e O O X O O O Wires O O O O O O Cables X O O O O O Plastic O O O O O O Solder X O O O O O Copper Alloy Brass X O O O O O This table is prepared in accordance with the provisions of SJ T 11364 O Indica...

Page 6: ...ICP Signal Conditioners Operating Manual with Enclosed Warranty Information 3425 Walden Avenue Depew New York 14043 2495 Phone 716 684 0003 Fax 716 684 3823 Toll Free Line 1 800 828 8840 MANUAL NUMBE...

Page 7: ...tents Introduction page 3 Description page 4 Operation page 5 Performance Limits page 8 Battery Considerations page 8 Optional Power Connections page 9 Warranty page 10 Calibration Service page 10 Ret...

Page 8: ...They are powered internally by three replaceable batteries and provide constant current excitation to the charge amplifier within ICP sensors or to in line and adaptor style amplifiers and decouples...

Page 9: ...el meter indicates the voltage output when connected to a sensor and is color coded for various fault conditions shown in Figure 1 2 Optional connections include sockets for EXT PWR and BATT CHG A cen...

Page 10: ...age with full scale set at 27 volts 27 volts for new batteries see Figure 1 When an ICP sensor is connector to the input XDCR jack the meter will indicate approximately mid scale 11 volts nominal if t...

Page 11: ...pacitor is fully charged Such drifting is considered normal operation Coupling Time Constant TC AC Coupled The coupling discharge time constant DTC is the product of the capacitor 47 F and the paralle...

Page 12: ...e 5 the low frequency response of the coupling circuit is determined by the relationship in Equation 2 This requires use of a BNC Tee Figure 6 below provides a comparison of AC vs DC coupling the same...

Page 13: ...driven but it sacrifices some high frequency response PCB line powered signal conditioners 482 Series 483 Series should be considered for cable lengths beyond 100 feet 31 meters as they provide up to...

Page 14: ...Charging WARNING models 480C02 480E09 do not ship with rechargeable batteries and PCB external battery chargers are suitable for use with Nickel Cadmium Ni Cad rechargeable batteries only It should no...

Page 15: ...lt a factory PCB applications engineer concerning the situation as certain problems can often be corrected with simple on site procedures PCB will perform calibrations on model 480C02 on request Typic...

Page 16: ...funded PCB offers to all customers at no charge 24 hour phone support This service makes product or application support available to our customers day or night seven days a week When unforeseen proble...

Page 17: ...Internal Battery Internal Battery Internal Battery Type 9V 9V Battery Life Standard Alkaline 50 hours 50 hours Power Required Alternate DC power DC power DC Power 15 mA 15 mA 5 Internal Battery Quanti...

Page 18: ......

Reviews: