background image

1

1

2

2

A

A

B

B

CODE

IDENT. NO.

52681

DWG. NO.

SCALE:

SHEET

DRAWN

CHECKED

ENGINEER

TITLE

UNLESS OTHERWISE SPECIFIED TOLERANCES ARE:

DIMENSIONS IN MILLIMETERS

[ IN BRACKETS ]

ANGLES

  

 

2 DEGREES

3425 WALDEN AVE. DEPEW, NY 14043

(716)  684-0001 E-MAIL:  [email protected]

DIMENSIONS  IN INCHES

ANGLES

  

 

2 DEGREES

FILLETS AND RADII 

 .003 - .005 

FILLETS AND RADII 

0.07 - 0.13 

OUTLINE DRAWING

55564

1 OF 1

1.5X

1/2" ICP MICROPHONE SYSTEM

 

DECIMALS     XX   ±.03

XXX   ±.010

DECIMALS    X   ± 0.8

XX   ± 0.25

JDM

5/27/15

JDM

5/27/15

NJL

5/27/15

55

56

4

PCB Piezotronics Inc. claims proprietary rights in

the information disclosed hereon.  Neither it nor any

reproduction thereof will be disclosed to others
without the written consent of PCB Piezotronics Inc.

REVISIONS

REV

DESCRIPTION

DIN

NR

RELEASED TO DRAFTING

44117

.43 [10.9]

3.05 [77.4]

.50 [12.7]

3.47 [88.3]

.03 [.8]

.50 [12.7]

Ø

.52 [13.2]

PREAMPLIFIER

MICROPHONE CARTRIDGE

BNC CONNECTOR (OUTPUT)

Summary of Contents for 378B13

Page 1: ...SYSTEM Installation and Operating Manual For assistance with the operation of this product contact PCB Piezotronics Inc Toll free 800 828 8840 24 hour SensorLine 716 684 0001 Fax 716 684 0987 E mail i...

Page 2: ...ty regimen When in doubt about a calibration cycle a good rule of thumb is to recalibrate on an annual basis It is also good practice to recalibrate after exposure to any severe temperature extreme sh...

Page 3: ...rchase Order should include authorization to proceed and return at current pricing which can be obtained from a factory customer service representative Contact Information International customers shou...

Page 4: ...isclosure Table Pb Hg Cd Cr VI PBB PBDE O O O O O O PCB X O O O O O O O O O O O X O O O O O O O O O O O O O O O O O O O O O O O O O X O O O O O O O O O X O O O O O O O O O O O X O O O O O X O O O O O...

Page 5: ...e O O X O O O Wires O O O O O O Cables X O O O O O Plastic O O O O O O Solder X O O O O O Copper Alloy Brass X O O O O O This table is prepared in accordance with the provisions of SJ T 11364 O Indica...

Page 6: ...he instrument will be used Whether for legal purposes or for quality assurance programs these standards will help determine the required quality accuracy and consistency of the instrument Standards th...

Page 7: ...ponse reactions of the human ear to the pressure fluctuations Some examples of typical sound pressure levels are shown in the table below dB Pressure Example 0 0 00002 Pa Threshold of Hearing 60 0 02...

Page 8: ...and noise cones the fre quency response of the microphone will be attenuated at higher frequencies Clamps and stands When holding a microphone in place it is important to minimize the influence of the...

Page 9: ...ceable to one or more of the following National Labs NIST PTB or DFM Our investment in equipment traceability and conformance to industry standards ensures accurate calibra tion against relevant speci...

Page 10: ...Output Voltage 7 Vpk 7 Vpk Output Impedance 50 Ohm 50 Ohm Physical Housing Material Stainless Alloy Stainless Alloy Venting Rear Rear 5 Electrical Connector BNC Jack BNC Jack Mounting Thread Grid 0 5...

Page 11: ...07 0 13 OUTLINE DRAWING 55564 1 OF 1 1 5X 1 2 ICP MICROPHONE SYSTEM DECIMALS XX 03 XXX 010 DECIMALS X 0 8 XX 0 25 JDM 5 27 15 JDM 5 27 15 NJL 5 27 15 55564 PCB Piezotronics Inc claims proprietary righ...

Reviews: