Model Number

377C41

PRECISION CONDENSER MICROPHONE

Revision: B
ECN #: 43881

Performance

ENGLISH

SI 

Nominal Microphone Diameter

1/2"

1/2"

Frequency Response Characteristic(at 0° incidence)

Free-Field

Free-Field

Open Circuit Sensitivity(at 250 Hz)

44.5 mV/Pa

44.5 mV/Pa

[2]

Open Circuit Sensitivity

(± 1.2 dB)(at 250 Hz)

-27 dB re 1 V/Pa

-27 dB re 1 V/Pa

[2]

Frequency Range(± 2 dB)

3.15 to 20,000 Hz

3.15 to 20,000 Hz

Lower Limiting Frequency(-3 dB)

1.0 to 2.4 Hz

1.0 to 2.4 Hz

Resonant Frequency(90° Phase Shift)

14,000 Hz

14,000 Hz

[1]

Dynamic Range(3% Distortion Limit)

>146 dB re 20 µPa >146 dB re 20 µPa

Dynamic Range

(Cartridge Thermal Noise)

<15 dB(A) re 20 µPa<15 dB(A) re 20 µPa [1]

Standards Designation(IEC 61094-4)

WS2F

WS2F

Environmental

Temperature Range(Operating)

-40 to +302 °F

-40 to +150 °C

Temperature Coefficient of Sensi14 to +122°F (-10 to +50°C))

0.0033 dB/°F

0.006 dB/°C

[1]

Static Pressure Coefficient

-0.01 dB/kPa

-0.01 dB/kPa

[1]

Influence of Humidity(0 to 95%, non-condensing)

-0.1 to 0.1 dB

-0.1 to 0.1 dB

Influence of Axial Vibration(0.1g (1 m/s²))

62 dB re 20 µPa

62 dB re 20 µPa

[1]

Influence of Magnetic Field(60 Hz, 80 A/m)

0 dB re 20 µPa

0 dB re 20 µPa

[1]

Long Term Stability(68°F (20°C))

>1000 years/dB

>1000 years/dB

Electrical

Capacitance(Polarized)

15 pF

15 pF

[1]

Polarization Voltage

200 V

200 V

Physical

Housing Material

Stainless Alloy

Stainless Alloy

Venting

Rear

Rear

Equivalent Volume

0.0027

45 mm³

[1][2]

Size (Diameter x Height)(with grid)

0.52 in x 0.64 in

13.2 mm x 16.3 mm

Size (Diameter x Height)

(without grid)

0.5 in x 0.61 in

12.7 mm x 15.5 mm

Weight

0.32 oz

9 gm

[1]

All specifications are at room temperature unless otherwise specified.
In the interest of constant product improvement, we reserve the right to change specifications without notice.

ICP

®

 is a registered trademark of PCB Group, Inc. 

NOTES:

[1]Typical.
[2]re 250 Hz

SUPPLIED ACCESSORIES: 

Model ACS-20 Calibration of Precision Condensor Microphones (1)

3425 Walden Avenue, Depew, NY 14043

Phone: 716-684-0001

Fax: 716-684-0987

E-Mail: [email protected]

OPTIONAL VERSIONS

Optional versions have identical specifications and accessories as listed for the standard 

model except where noted below. More than one option may be used.

Entered: AP

Engineer: MT

Sales: MV

Approved: MT

Spec Number:

Date: 2/23/2015

Date: 2/23/2015

Date: 2/23/2015

Date: 2/23/2015

51121 

Summary of Contents for 377C41

Page 1: ...Microphone Installation and Operating Manual For assistance with the operation of this product contact PCB Piezotronics Inc Toll free 800 828 8840 24 hour SensorLine 716 684 0001 Fax 716 684 0987 E m...

Page 2: ...alized tests including sensitivity at elevated or cryogenic temperatures phase response extended high or low frequency response extended range leak testing hydrostatic pressure testing and others For...

Page 3: ...tion on particular operating steps The following symbols may be found on the equipment described in this manual This symbol on the unit indicates that high voltage may be present Use standard safety p...

Page 4: ...China RoHS 2 Disclosure Table Pb Hg Cd Cr VI PBB PBDE O O O O O O PCB X O O O O O O O O O O O X O O O O O O O O O O O O O O O O O O O O O O O O O X O O O O O O O O O X O O O O O O O O O O O X O O O O...

Page 5: ...O Wires O O O O O O Cables X O O O O O Plastic O O O O O O Solder X O O O O O Copper Alloy Brass X O O O O O This table is prepared in accordance with the provisions of SJ T 11364 O Indicates that sai...

Page 6: ...in which the instrument will be used Whether for legal purposes or for quality assurance programs these standards will help determine the required quality accuracy and consistency of the instrument St...

Page 7: ...owered with a 24V or a 12V phantom power supply but this will limit the maximum output voltage Externally Polarized Microphone System Prepolarized Microphone System Phantom Powered Microphone System T...

Page 8: ...em such as the preamplifier signal conditioner or instrumentation Conversely the Cartridge Thermal Noise CTN specification provides the lowest measurable sound pressure level that can be detected abov...

Page 9: ...rugged grid cap shown below and as an independent part of a rugged kit to extend the lifespan of the precision measuring device caution should be taken to ensure the delicate diaphragm sensing element...

Page 10: ...ustry standards ensures accurate calibra tion against relevant specifications We also carry a line of acoustic calibrators that can be used to calibrate microphone sensitivity on site as needed Hand c...

Page 11: ...Pa 62 dB re 20 Pa 1 Influence of Magnetic Field 60 Hz 80 A m 0 dB re 20 Pa 0 dB re 20 Pa 1 Long Term Stability 68 F 20 C 1000 years dB 1000 years dB Electrical Capacitance Polarized 15 pF 15 pF 1 Pola...

Page 12: ......

Reviews: