background image

Model Number

3741F122G

DC RESPONSE ACCELEROMETER

Revision: A

ECN #: 49164

[8]

Performance

ENGLISH

SI

Sensitivity(± 3 %)

1350 mV/g

137.6 mV/(m/s²)

[6]

Measurement Range

± 2 g pk

± 19.6 m/s² pk

Frequency Range(± 5 %)

0 to 250 Hz

0 to 250 Hz

Frequency Range

(± 10 %)

0 to 350 Hz

0 to 350 Hz

Resonant Frequency

1.2 kHz

1.2 kHz

[2]

Phase Response(10 Hz)

<2.5 °

<2.5 °

Broadband Resolution(0.5 to 100 Hz)

0.1 mg rms

.001 m/s² rms

[2]

Non-Linearity

≤ 1 % FS

≤ 1 % FS

[7]

Transverse Sensitivity

≤ 3 %

≤ 3 %

Environmental

Overload Limit(Shock)

± 5000 g pk

± 49,050 m/s² pk

Temperature Range(Operating)

-65 to 250 °F

-54.0 to 121 °C

Temperature Range

(Storage)

-65 to 250 °F

-54.0 to 121 °C

Temperature Coefficient of Sensitivity

± 2.5 %

± 2.5 %

[4]

Zero g Offset Temperature Coefficient

± 1.5 % FSO

± 1.5 % FSO

[5][4]

Base Strain Sensitivity

.002 g/µε

.02 (m/s²)/µε

[2]

Magnetic Sensitivity

200 µg/gauss

19.6 (m/s²)/Tesla

[2]

Electrical

Excitation Voltage

5 to 32 VDC

5 to 32 VDC

Current Consumption

≤ 5 mA

≤ 5 mA

Output Impedance

≤ 120 Ohm

≤ 120 Ohm

Offset Voltage(0 g)

± 20 mVDC

± 20 mVDC

[1]

Common Mode Voltage(± 0.1 VDC)

+1.65 VDC

+1.65 VDC

Spectral Noise(1 to 100 Hz)

10 µg/√Hz

98.1 (µm/sec

2

)/√Hz

[2]

Electrical Isolation(Case)

>10

8

 Ohm

>10

8

 Ohm

[3]

Physical

Housing Material

Anodized Aluminum

Anodized Aluminum

Sealing

Epoxy

Epoxy

Size (Height x Length x Width)

0.30 in x 1.00 in x .85 in

7.62 mm x 25.4 mm x 21.6 mm

Weight(without cable)

0.35 oz

9.92 gm

[2]

Electrical Connector

Integral Cable

Integral Cable

Electrical Connection Position

Side

Side

Cable Termination

Pigtail Ends

Pigtail Ends

Cable Type

010 4-cond Shielded

010 4-cond Shielded

Cable Length

10 ft

3 m

Mounting

Through Holes (2)

Through Holes (2)

All specifications are at room temperature unless otherwise specified.
In the interest of constant product improvement, we reserve the right to change specifications without notice.

This model, designated with an RH prefix, is RoHS compliant. For further details, and to obtain PCB's RoHS 

Statement of Conformance, please visit http://www.pcb.com 

OPTIONAL VERSIONS

Optional versions have identical specifications and accessories as listed for the standard model 

except where noted below. More than one option may be used.

NOTES:

[1] Offset tolerance is based on manufacturers supplied cable length.

[2] Typical.

[3] Case and shield to mounting surface or cable leads.

[4] -65 to +250 °F, ref. 75 °F (-54 to +121 °C, ref. 24 °C)
[5] FSO= Full Scale Output over the Measurement Range

[6] Measured at 5 Hz, 0.5 grms.

[7] Zero-based, least-squares, straight line method.
[8] See PCB Declaration of Conformance PS027 for details.

SUPPLIED ACCESSORIES: 

Model 081A103 Mounting screw (2)

Model ACS-85 Phase and Magnitude calibration from 0.5 Hz to 5% pt Linear scale (1)
Model M081A103 Mounting screw and washer, M3 x 0.5 thread (2)

OPTIONAL ACCESSORIES: 

Model 080A208 Triaxial mounting block

Entered: LK

Engineer: NJF

Sales: WDC

Approved: NJF

Spec Number:

Date: 2/15/2019

Date: 2/15/2019

Date: 2/15/2019

Date: 2/15/2019

69810 

3425 Walden Avenue, Depew, NY 14043

Phone: 716-684-0001
Fax: 716-684-0987

E-Mail: [email protected]

Summary of Contents for 3741F122G

Page 1: ...mV g 2 g 10 ft integral cable Installation and Operating Manual For assistance with the operation of this product contact the PCB Piezotronics Inc Toll free 716 684 0001 24 hour SensorLine 716 684 00...

Page 2: ...alized tests including sensitivity at elevated or cryogenic temperatures phase response extended high or low frequency response extended range leak testing hydrostatic pressure testing and others For...

Page 3: ...tion on particular operating steps The following symbols may be found on the equipment described in this manual This symbol on the unit indicates that high voltage may be present Use standard safety p...

Page 4: ...China RoHS 2 Disclosure Table Pb Hg Cd Cr VI PBB PBDE O O O O O O PCB X O O O O O O O O O O O X O O O O O O O O O O O O O O O O O O O O O O O O O X O O O O O O O O O X O O O O O O O O O O O X O O O O...

Page 5: ...O Wires O O O O O O Cables X O O O O O Plastic O O O O O O Solder X O O O O O Copper Alloy Brass X O O O O O This table is prepared in accordance with the provisions of SJ T 11364 O Indicates that sai...

Page 6: ...e applied acceleration The sensor element is electrically connected in a Wheatstone bridge circuit The integral amplifier provides a low impedance output to follow on instrumentation These particular...

Page 7: ...ssembly With each conductor being 30 AWG Teflon coated The supplied cable length for a standard DC accelerometer is 10 ft or 120 in 3 m Custom cable length requirements should be specified at time of...

Page 8: ...and stiff adhesives provide the best high frequency response METHOD 1 Adhesive Mounting Base This method involves attaching a base to the test structure then securing the sensor to the base This allow...

Page 9: ...es to reduce the effects of EMI and RFI that is present near electrical motors and machinery Teflon jacketed cabling may be necessary to withstand corrosive environments and higher temperatures Feel f...

Page 10: ...its provide the capability for continuous monitoring Note High sensitivity DC Accelerometers feature on board differential amplification 7 0 OPERATING NOTE Always operate the accelerometer within the...

Page 11: ...s and costly errors Therefore in an effort to prevent the common mistakes associated with customer performed calibration this document includes a broad overview of the Back to Back Calibration techniq...

Page 12: ...usly calibrated over the frequency and or amplitude range of interest 2 the shaker should be selected to provide minimal transverse lateral motion and minimal distortion and 3 the quality of the meter...

Page 13: ...eturn policies and instructions When unexpected measurement problems arise call our 24 hour SensorLineSM to discuss your immediate dynamic instrumentation needs with a factory representative Dial 716...

Page 14: ...able Electrical Connection Position Side Side Cable Termination Pigtail Ends Pigtail Ends Cable Type 010 4 cond Shielded 010 4 cond Shielded Cable Length 10 ft 3 m Mounting Through Holes 2 Through Hol...

Page 15: ...1 MODEL 081A103 MOUNTING SCREW ASSEMBLY 2 SUPPLIED FOR M OPTION MODEL M081A103 MOUNTING SCREW ASSEMBLY 2 SUPPLIED FOR METRIC OPTION MOUNTING HOLE PREPARATION 098 2 45 39 10 0 MIN M3x0 5 6H 18 4 6 MIN...

Page 16: ...ormation disclosed hereon Neither it nor any reproduction thereof will be disclosed to others without the written consent of PCB Piezotronics Inc REVISIONS REV DESCRIPTION DIN SEE SHEET 1 FASTEN CABLE...

Reviews: