Service 

–  Due  to  the  sophisticated 

nature  of  the  sensors  and  associated 
instrumentation 

provided 

by 

PCB 

Piezotronics,  user  servicing  or  repair  is 
not  recommended  and,  if  attempted, 
may  void  the  factory  warranty.  Routine 
maintenance,  such  as  the  cleaning  of 
electrical  connectors,  housings,  and 
mounting  surfaces  with  solutions  and 
techniques  that  will  not  harm  the 
physical  material  of  construction,  is 
acceptable. Caution should be observed 
to  ensure  that  liquids  are  not  permitted 
to  migrate  into  devices  that  are  not 
hermetically 

sealed. 

Such 

devices 

should  only  be  wiped  with  a  dampened 
cloth  and  never  submerged  or  have 
liquids poured upon them.   
 

Repair 

–  In  the  event  that  equipment 

becomes 

damaged 

or 

ceases 

to 

operate,  arrangements  should  be  made 
to  return  the  equipment  to  PCB 
Piezotronics for repair. User servicing or 
repair  is  not  recommended  and,  if 
attempted, 

may 

void 

the 

factory 

warranty.     
 

Calibration 

–  Routine  calibration  of 

sensors  and  associated  instrumentation 
is  recommended  as  this  helps  build 
confidence  in  measurement  accuracy 
and 

acquired 

data. 

Equipment 

calibration 

cycles 

are 

typically 

established  by  the  users  own  quality 
regimen.  When  in  doubt  about  a 
calibration cycle, a good 

“rule of thumb” 

is to recalibrate on an annual basis. It is 

also  good  practice  to  recalibrate  after 
exposure  to  any  severe  temperature 
extreme, 

shock, 

load, 

or 

other 

environmental  influence,  or  prior  to  any 
critical test.  
 
PCB  Piezotronics  maintains  an  ISO- 
9001  certified  metrology  laboratory  and 
offers  calibration  services,  which  are 
accredited  by  A2LA  to  ISO/IEC  17025, 
with  full  traceability  to  SI  through 
N.I.S.T.  In  addition  to  the  normally 
supplied  calibration,  special  testing  is 
also  available,  such  as:  sensitivity  at 
elevated  or  cryogenic  temperatures, 
phase  response,  extended  high  or  low 
frequency  response,  extended  range, 
leak 

testing, 

hydrostatic 

pressure 

testing,  and  others.  For  information  on 
standard 

recalibration 

services 

or 

special  testing,  contact  your  local  PCB 
Piezotronics 

distributor, 

sales 

representative,  or  factory  customer 
service representative.   
 

Returning  Equipment 

– 

Following 

these  procedures  will  ensure  that  your 
returned  materials  are  handled  in  the 
most 

expedient 

manner

Before 

returning 

any 

equipment 

to 

PCB 

Piezotronics, 

contact 

your 

local 

distributor,  sales  representative,  or 
factory  customer  service  representative 
to  obtain  a  Return 

Warranty,  Service, 

Repair,  and  Return  Policies  and 
Instructions 

Materials  Authorization 

(RMA)  Number.  This  RMA  number 
should be clearly marked on the outside 
of  all  package(s)  and  on  the  packing 

Service, Repair, and Return 
Policies and Instructions 

Summary of Contents for 3741E1210G

Page 1: ...elerometer Installation and Operating Manual For assistance with the operation of this product contact PCB Piezotronics Inc Toll free 800 828 8840 24 hour SensorLine 716 684 0001 Fax 716 684 0987 E ma...

Page 2: ...ty regimen When in doubt about a calibration cycle a good rule of thumb is to recalibrate on an annual basis It is also good practice to recalibrate after exposure to any severe temperature extreme sh...

Page 3: ...rchase Order should include authorization to proceed and return at current pricing which can be obtained from a factory customer service representative Contact Information International customers shou...

Page 4: ...isclosure Table Pb Hg Cd Cr VI PBB PBDE O O O O O O PCB X O O O O O O O O O O O X O O O O O O O O O O O O O O O O O O O O O O O O O X O O O O O O O O O X O O O O O O O O O O O X O O O O O X O O O O O...

Page 5: ...e O O X O O O Wires O O O O O O Cables X O O O O O Plastic O O O O O O Solder X O O O O O Copper Alloy Brass X O O O O O This table is prepared in accordance with the provisions of SJ T 11364 O Indica...

Page 6: ...e applied acceleration The sensor element is electrically connected in a Wheatstone bridge circuit The integral amplifier provides a low impedance output to follow on instrumentation These particular...

Page 7: ...ssembly With each conductor being 30 AWG Teflon coated The supplied cable length for a standard DC accelerometer is 10 ft or 120 in 3 m Custom cable length requirements should be specified at time of...

Page 8: ...and stiff adhesives provide the best high frequency response METHOD 1 Adhesive Mounting Base This method involves attaching a base to the test structure then securing the sensor to the base This allow...

Page 9: ...es to reduce the effects of EMI and RFI that is present near electrical motors and machinery Teflon jacketed cabling may be necessary to withstand corrosive environments and higher temperatures Feel f...

Page 10: ...its provide the capability for continuous monitoring Note High sensitivity DC Accelerometers feature on board differential amplification 7 0 OPERATING NOTE Always operate the accelerometer within the...

Page 11: ...s and costly errors Therefore in an effort to prevent the common mistakes associated with customer performed calibration this document includes a broad overview of the Back to Back Calibration techniq...

Page 12: ...usly calibrated over the frequency and or amplitude range of interest 2 the shaker should be selected to provide minimal transverse lateral motion and minimal distortion and 3 the quality of the meter...

Page 13: ...eturn policies and instructions When unexpected measurement problems arise call our 24 hour SensorLineSM to discuss your immediate dynamic instrumentation needs with a factory representative Dial 716...

Page 14: ...ral Cable Integral Cable Electrical Connection Position Side Side Cable Termination Pigtail Ends Pigtail Ends Cable Type 010 4 cond Shielded 010 4 cond Shielded Cable Length 10 ft 10 ft Mounting Throu...

Page 15: ...MIN POWER RED POWER SIGNAL GROUND BLACK OUTPUT WHITE OUTPUT YELLOW MODEL 081A103 MOUNTING SCREW ASSEMBLY 2 SUPPLIED FOR M OPTION MODEL M081A103 MOUNTING SCREW ASSEMBLY 2 SUPPLIED POWER RED CONNECT TO...

Page 16: ...rmation disclosed hereon Neither it nor any reproduction thereof will be disclosed to others without the written consent of PCB Piezotronics Inc REVISIONS REV DESCRIPTION DIN SEE SHEET 1 FASTEN CABLE...

Reviews: