1
1
2
2
3
3
4
4
A
A
B
B
CODE
IDENT. NO.
52681
DWG. NO.
SCALE:
SHEET
DRAWN
CHECKED
ENGINEER
TITLE
UNLESS OTHERWISE SPECIFIED TOLERANCES ARE:
DIMENSIONS IN MILLIMETERS
[ IN BRACKETS ]
XX
±
0.13
ANGLES
2 DEGREES
3425 WALDEN AVE. DEPEW, NY 14043
(716) 684-0001 E-MAIL: [email protected]
DIMENSIONS IN INCHES
DECIMALS XX
±.01
ANGLES
2 DEGREES
FILLETS AND RADII
.003 - .005
DECIMALS X
±
0.3
FILLETS AND RADII
0.07 - 0.13
INSTALLATION DRAWING
17764
2 OF 2
2X
ACCELEROMETER
XXX ±.005
JDM
6/12/17
JDM
6/12/17
GGD
6/12/17
REVISIONS
REV
DESCRIPTION
DIN
-SEE
SHEET
1-
17
76
4
PCB Piezotronics Inc. claims proprietary rights in
the information disclosed hereon. Neither it nor any
reproduction thereof will be disclosed to others
without the written consent of PCB Piezotronics Inc.
3 - 4 [76 - 102]
3 - 4 [76 - 102]
7
7
TAPE, PETRO WAX
OR EQUIVALENT
(TYPICAL)
"SERVICE LOOP"
TO ALLOW MOTION
WITHOUT PULLING CABLE.
TEST STRUCTURE
MODEL 030A10
MINI COAXIAL TO
10-32 COAXIAL PLUG
MODEL 352C23
SENSOR
8.) TO AVOID UNNECESSARY DAMAGE TO THE SENSOR AND/OR CABLE, USE THE SUPPLIED REMOVAL TOOL
(MODEL 039A26). A QUICK TWISTING MOTION WILL FREE THE SENSOR FROM THE TEST STRUCTURE.
FASTEN CABLE TO TEST STRUCTURE TYPICALLY WITHIN 3-4 [76-101] OF SENSOR. THEN FASTEN AGAIN WITHIN
3-4 [76-101] OF PREVIOUS ATTACHMENT. BETWEEN THE TEST STRUCTURE AND A FIXED STRUCTURE, ALLOW A
SERVICE LOOP LARGE ENOUGH TO PREVENT PULLING OF THE CABLE WHEN SHAKING. MORE ATTACHMENT
POINTS WILL PROVIDE LESS NOISE IN THE RESULTING DATA. LOOSE CABLES OR PARTS ELSEWHERE ON THE
TEST STRUCTURE CAN ALSO GENERATE "NOISE" ON THE SIGNAL RECEIVED FROM THE SENSOR.