background image

Model Number

260A 13

Revision: R
ECN #: 50553

P erfo rm an ce

EN G L ISH

SI

Sensitivity(± 15 %)(Z Axis)

15 pC/lb

3.37 pC/N

[1]

Sensitivity

(± 15 %)(X or Y Axis)

32 pC/lb

7.19 pC/N

[1]

Measurement Range(Z Axis)

10,000 lb

44.48 kN

Measurement Range

(X or Y Axis)

4,000 lb

17.7 kN

Maximum Force(z axis)

11,000 lb

48.93 kN

Maximum Force

(x or y axis)

4,400 lb

19.57 kN

Maximum Moment(z axis)

240 ft-lb

325.4 Nm

Maximum Moment

(x or y axis)

325 ft-lb

440.7 Nm

Upper Frequency Limit

39,000 Hz

39,000 Hz

Non-Linearity

≤ 1 % FS

≤ 1 % FS

[2]

Cross Talk(between x and y axis)

± 3 %

± 3 %

Cross Talk

(between (x or y axis) and z axis)

± 5 %

± 5 %

En viro n m en tal

Temperature Range

-100 to +350 °F

-73 to +177 °C

Electrical

Capacitance(all channels)

70 pF

70 pF

[3]

Insulation Resistance(all channels)

≥ 10

12

 Ohm

≥ 10

12

 Ohm

Output Polarity(in direction of markings)

Negative

Negative

P h ysical

Preload

≤ 40,000 lb

≤ 178 kN

[4]

Stiffness(z axis)

38.8 lb/µin

6.8 kN/µm

[3]

Stiffness

(x or y axis)

11.4 lb/µin

2.0 kN/µm

[3]

Size (Height x Length x Width x Bolt
Diameter x ID x Sensing Surface)

0.790 in x 2.25 in x 2.25 in x 1

in x 1.023 in x 1.800 in

20.07 mm x 57.1 mm x 57.1

mm x 25 mm x 25.98 mm x

45.72 mm

Weight

9.88 oz

280 gm

Housing Material

Stainless Steel

Stainless Steel

Sealing

Hermetic

Hermetic

Electrical Connector(Quantity, 3)

10-32 Coaxial Jack

10-32 Coaxial Jack

Electrical Connection Position

Side

Side

All specifications are at room temperature unless otherwise specified.
In the interest of constant product improvement, we reserve the right to change specifications without notice.

ICP

®

 is a registered trademark of PCB Piezotronics, Inc.

W

 - Water Resistant Cable

Electrical Connection Position

Side

Side

OP TION A L  VERSION S

Optional versions have identical specifications and accessories as listed for the standard model except

where noted below. More than one option may be used.

N OTES:

[1]Sensitivites are for listed preload. Sensitivites may vary ±5% depending on preload used.
[2]Zero-based, least-squares, straight line method.
[3]Typical.
[4]Preload should be at least 10 times the X and Y operating range used.

Date: 04/17/2020

Date: 04/17/2020

Date: 04/17/2020

Date: 04/17/2020

6231

Entered: LK

Engineer: RPF

Sales: KK

Approved: RPF

Spec Number:

3425 Walden Avenue, Depew, NY 14043

Phone: 716-684-0001
Fax: 716-684-0987
E-Mail: [email protected]

SU P P L IED A C C ESSORIES:

Model 081A71 Mounting Stud (1)
Model 082B06 Anti-Friction Washer (1)
Model 083A11 Pilot Bushing (1)
Model M081A71 Mounting Stud (1)

Summary of Contents for 260A13

Page 1: ...Fx y 15 pC lb z 32 pC lb x y Installation and Operating Manual For assistance with the operation of this product contact PCB Piezotronics Inc Toll free 800 828 8840 24 hour SensorLine 716 684 0001 Fax 716 684 0987 E mail info pcb com Web www pcb com ...

Page 2: ...ialized tests including sensitivity at elevated or cryogenic temperatures phase response extended high or low frequency response extended range leak testing hydrostatic pressure testing and others For more information contact your local PCB Piezotronics distributor sales representative or factory customer service representative Returning Equipment If factory repair is required our representatives ...

Page 3: ...ation on particular operating steps The following symbols may be found on the equipment described in this manual This symbol on the unit indicates that high voltage may be present Use standard safety precautions to avoid personal contact with this voltage This symbol on the unit indicates that the user should refer to the operating instructions located in the manual This symbol indicates safety ea...

Page 4: ...E 住房 O O O O O O PCB板 X O O O O O 电气连接器 O O O O O O 压电晶体 X O O O O O 环氧 O O O O O O 铁氟龙 O O O O O O 电子 O O O O O O 厚膜基板 O O X O O O 电线 O O O O O O 电缆 X O O O O O 塑料 O O O O O O 焊接 X O O O O O 铜合金 黄铜 X O O O O O 本表格依据 SJ T 11364 的规定编制 O 表示该有害物质在该部件所有均质材料中的含量均在 GB T 26572 规定的限量要求以下 X 表示该有害物质至少在该部件的某一均质材料中的含量超出 GB T 26572 规定的限量要求 铅是欧洲RoHS指令2011 65 EU附件三和附件四目前由于允许的豁免 CHINA RoHS COMPLIANCE ...

Page 5: ... O Wires O O O O O O Cables X O O O O O Plastic O O O O O O Solder X O O O O O Copper Alloy Brass X O O O O O This table is prepared in accordance with the provisions of SJ T 11364 O Indicates that said hazardous substance contained in all of the homogeneous materials for this part is below the limit requirement of GB T 26572 X Indicates that said hazardous substance contained in at least one of t...

Page 6: ......

Page 7: ......

Page 8: ......

Page 9: ......

Page 10: ......

Page 11: ......

Page 12: ......

Page 13: ...5 98 mm x 45 72 mm Weight 9 88 oz 280 gm HousingMaterial Stainless Steel Stainless Steel Sealing Hermetic Hermetic Electrical Connector Quantity 3 10 32 Coaxial Jack 10 32 Coaxial Jack Electrical Connection Position Side Side All specifications are at room temperature unless otherwise specified In the interest of constant product improvement we reserve the right tochange specifications without not...

Page 14: ......

Page 15: ......

Page 16: ......

Reviews: