Model Number
1630-04C
STRAIN GAGE LOAD CELL
Revision: C
ECN #: 41486
Performance
ENGLISH
SI
Measurement Range
100 lb
445 N
[5]
Sensitivity(± 10 %)
2 mV/V
2 mV/V
[6]
Non-Linearity
≤
0.05 % FS
≤
0.05 % FS
Hysteresis
≤
0.03 % FS
≤
0.03 % FS
Non-Repeatability
≤
0.02 %RO
≤
0.02 %RO
Resonant Frequency
1.8 kHz
1.8 kHz
Creep(in 20 minutes)
≤
0.08 %
≤
0.08 %
Environmental
Overload Limit
150 lb
667 N
Load Limit(Side Force, F
X
or F
Y
)
10 lb
44.5 N
[3]
Load Limit
(Bending Moment, M
X
or M
Y
)
20 in-lb
2.26 Nm
[3]
Load Limit
(Axial Torque, M
Z
)
20 in-lb
2.26 Nm
[3]
Temperature Range(Operating)
0 to +200 °F
-18 to +93 °C
Temperature Range
(Compensated)
+70 to +170 °F
+21 to +77 °C
Temperature Effect on Output(Maximum)
± 0.0008 %Reading/°F
± 0.0015 %Reading/°C
[4]
Temperature Effect on Zero Balance(Maximum)
± 0.0015 %FS/°F
± 0.027 %FS/°C
[4]
Electrical
Bridge Resistance
350 Ohm
350 Ohm
[1]
Excitation Voltage(Recommended)
10 VDC
10 VDC
[2]
Insulation Resistance
>5x10
9
Ohm
>5x10
9
Ohm
Zero Balance
± 1 % FS
± 1 % FS
Physical
Size (Length x Height x Width)
2.00 in x 2.50 in x 0.625 in
51 mm x 64 mm x 16 mm
Weight
0.23 lb
104 g
Mounting Thread
1/4-28 thread
No Metric Equivalent
Housing Material
Aluminum
Aluminum
Sensing Element
Strain Gage
Strain Gage
Deflection at Full Scale Capacity
0.002 in
0.05 mm
Electrical Connector
10 ft - Integrated Cable
10 ft - Integrated Cable
Electrical Connection Position
Side
Side
All specifications are at room temperature unless otherwise specified.
In the interest of constant product improvement, we reserve the right to change specifications without notice.
ICP
®
is a registered trademark of PCB Group, Inc.
OPTIONAL VERSIONS
Optional versions have identical specifications and accessories as listed for the standard model
except where noted below. More than one option may be used.
NOTES:
[1] Nominal.
[2] Calibrated at 10 VDC, usable 5 to 20 VDC or VAC RMS.
[3] Singularly applied, i.e. no other extraneous loads.
[4] Over compensated operating temperature range.
[5] FS - Full Scale.
[6] RO - Rated Output.
Entered: AP
Engineer: JSD
Sales: KWW
Approved: DA
Spec Number:
Date: 6/12/2013
Date: 6/12/2013
Date: 6/12/2013
Date: 6/12/2013
45995
PCB Load & Torque, Inc.
24350 Indoplex Circle
Farmington Hills, MI 48335
UNITED STATES
Phone: 866-684-7107
Fax: 716-684-0987
E-Mail: [email protected]
Web site: http://www.pcbloadtorque.com