PCB Piezotronics 1630-04C Installation And Operating Manual Download Page 9

 

Model Number

 

1630-04C

 

STRAIN GAGE LOAD CELL

 

Revision: C 

ECN #: 41486

 

 

Performance 

ENGLISH 

SI 

Measurement Range

 

100 lb

 

445 N

 

[5]

 

Sensitivity(± 10 %)

 

2 mV/V

 

2 mV/V

 

[6]

 

Non-Linearity

 

 0.05 % FS

 

 0.05 % FS

 

 

Hysteresis

 

 0.03 % FS

 

 0.03 % FS

 

 

Non-Repeatability

 

 0.02 %RO

 

 0.02 %RO

 

 

Resonant Frequency

 

1.8 kHz

 

1.8 kHz

 

 

Creep(in 20 minutes)

 

 0.08 %

 

 0.08 %

 

 

Environmental 

Overload Limit

 

150 lb

 

667 N

 

 

Load Limit(Side Force, F

X

 or F

Y

)

 

10 lb

 

44.5 N

 

[3]

 

Load Limit

(Bending Moment, M

X

 or M

Y

)

 

20 in-lb

 

2.26 Nm

 

[3]

 

Load Limit

(Axial Torque, M

Z

)

 

20 in-lb

 

2.26 Nm

 

[3]

 

Temperature Range(Operating)

 

0 to +200 °F

 

-18 to +93 °C

 

 

Temperature Range

(Compensated)

 

+70 to +170 °F

 

+21 to +77 °C

 

 

Temperature Effect on Output(Maximum)

 

± 0.0008 %Reading/°F

 

± 0.0015 %Reading/°C

 

[4]

 

Temperature Effect on Zero Balance(Maximum)

 

± 0.0015 %FS/°F

 

± 0.027 %FS/°C

 

[4]

 

Electrical 

Bridge Resistance

 

350 Ohm

 

350 Ohm

 

[1]

 

Excitation Voltage(Recommended)

 

10 VDC

 

10 VDC

 

[2]

 

Insulation Resistance

 

>5x10

9

 Ohm

 

>5x10

9

 Ohm

 

 

Zero Balance

 

± 1 % FS

 

± 1 % FS

 

 

Physical 

Size (Length x Height x Width)

 

2.00 in x 2.50 in x 0.625 in

 

51 mm x 64 mm x 16 mm

 

 

Weight

 

0.23 lb

 

104 g

 

 

Mounting Thread

 

1/4-28 thread

 

No Metric Equivalent

 

 

Housing Material

 

Aluminum

 

Aluminum

 

 

Sensing Element

 

Strain Gage

 

Strain Gage

 

 

Deflection at Full Scale Capacity

 

0.002 in

 

0.05 mm

 

 

Electrical Connector

 

10 ft - Integrated Cable

 

10 ft - Integrated Cable

 

 

Electrical Connection Position

 

Side

 

Side

 

 

All specifications are at room temperature unless otherwise specified. 
In the interest of constant product improvement, we reserve the right to change specifications without notice. 

ICP

®

 is a registered trademark of PCB Group, Inc. 

 

OPTIONAL VERSIONS 

Optional versions have identical specifications and accessories as listed for the standard model 

except where noted below. More than one option may be used.

 

 
 
 
 

 

 

NOTES:

[1] Nominal.
[2] Calibrated at 10 VDC, usable 5 to 20 VDC or VAC RMS.
[3] Singularly applied, i.e. no other extraneous loads.
[4] Over compensated operating temperature range.
[5] FS - Full Scale.
[6] RO - Rated Output.

 

Entered: AP

 

Engineer: JSD

 

Sales: KWW

 

Approved: DA

 

Spec Number:

 

Date: 6/12/2013

 

Date: 6/12/2013

 

Date: 6/12/2013

 

Date: 6/12/2013

 

45995 

 

PCB Load & Torque, Inc. 
24350 Indoplex Circle 
Farmington Hills, MI 48335 
UNITED STATES 
Phone: 866-684-7107 
Fax: 716-684-0987 
E-Mail: [email protected] 
Web site: http://www.pcbloadtorque.com 

Summary of Contents for 1630-04C

Page 1: ...stallation and Operating Manual For assistance with the operation of this product contact PCB Load Torque Inc Toll free 866 684 7107 24 hour SensorLine 716 684 0001 Fax 248 888 8266 E mail LTInfo pcbl...

Page 2: ...id the factory warranty Calibration Routine calibration of sensors and associated instrumentation is recommended as this helps build confidence in measurement accuracy and acquired data Equipment cali...

Page 3: ...warranty against defective material and workmanship for a period of one year from date of original purchase Contact PCB for a complete statement of our warranty Expendable items such as batteries and...

Page 4: ...erations 3 6 0 CALIBRATION 3 6 1 Calibration Certificate Description 3 6 1 1 Measured Output 3 6 1 2 Hysteresis 4 6 1 3 Best Fit Output 4 6 1 4 Strain Gage Measurements 4 6 1 5 Shunt Calibration Stand...

Page 5: ...50 lbf to 5k lbf 3 1 Dimensions 4 0 MECHANICAL INSTALLATION Loads applied to S type load cells must be even and centered Compensation linkages e g rod end bearing alignment couplers are recommended to...

Page 6: ...or noisy signals A simple test with a voltmeter connected between the power cord ground and the structure on which the load cell is mounted can confirm that the structure has been properly grounded I...

Page 7: ...cision shunt resistor is 60 000 ohms 0 1 simulates an output of approximately 73 of the full scale output for the load cell The calibration values for each bridge are found on the calibration certific...

Page 8: ...aboratory in Farmington Hills Michigan is A2LA Accredited per ISO IEC 17025 Standard calibration certificates list five force points ascending and one point descending Additional data points are avail...

Page 9: ...104 g Mounting Thread 1 4 28 thread No Metric Equivalent Housing Material Aluminum Aluminum Sensing Element Strain Gage Strain Gage Deflection at Full Scale Capacity 0 002 in 0 05 mm Electrical Conne...

Page 10: ......

Reviews: