PCB Piezotronics 1630-04C Installation And Operating Manual Download Page 4

 

PCB Load & Torque, Inc.   

 Toll-Free in USA 866-684-7107   

 716-684-0001   

 www.pcbloadtorque.com

 

 

 

S-TYPE LOAD CELL OPERATION MANUAL 

 

1

 

TABLE OF CONTENTS 

 

1.0 INTRODUCTION.................................................................................................................. 2

 

 

2.0 SAFETY PRECAUTIONS .................................................................................................... 2

 

 

3.0 OVERVIEW .......................................................................................................................... 2

 

3.1 Dimensions .......................................................................................................................................2

 

 

4.0 MECHANICAL INSTALLATION .......................................................................................... 2

 

 

5.0 ELECTRICAL INSTALLATION ........................................................................................... 2

 

5.1 Electrical Drawing / Western Regional Std. ......................................................................................3

 

5.2 Output Polarity ..................................................................................................................................3

 

5.3 Cable & Grounding Considerations ..................................................................................................3

 

 

6.0 CALIBRATION..................................................................................................................... 3

 

6.1 Calibration Certificate Description.....................................................................................................3

 

6.1.1 Measured Output.....................................................................................................................3

 

6.1.2 Hysteresis................................................................................................................................4

 

6.1.3 Best Fit Output ........................................................................................................................4

 

6.1.4 Strain Gage Measurements .....................................................................................................4

 

6.1.5 Shunt Calibration Standard Resistor .......................................................................................4

 

6.1.6 Static Error Band (SEB)..........................................................................................................4

 

 

7.0 SHUNT CALIBRATION DESCRIPTION.............................................................................. 4

 

7.1 Resistor Value ...................................................................................................................................4

 

7.2 Shunt Calibration Process.................................................................................................................4

 

7.3 Estimating Shunt Resistor for a Given Load .....................................................................................4

 

 

8.0 MAINTENANCE................................................................................................................... 4

 

 

9.0 TROUBLE SHOOTING ........................................................................................................ 5

 

9.1 Mechanical Trouble Shooting ...........................................................................................................5

 

9.2 Electrical Trouble Shooting ...............................................................................................................5

 

 

10.0 CALIBRATION / REPAIR SERVICES ............................................................................... 5

 

10.1 RMA / Purchase Order....................................................................................................................5

 

 

11.0 WARRANTY ...................................................................................................................... 5

 

 
 
 
 
 
 
 
 
 
 

Summary of Contents for 1630-04C

Page 1: ...stallation and Operating Manual For assistance with the operation of this product contact PCB Load Torque Inc Toll free 866 684 7107 24 hour SensorLine 716 684 0001 Fax 248 888 8266 E mail LTInfo pcbl...

Page 2: ...id the factory warranty Calibration Routine calibration of sensors and associated instrumentation is recommended as this helps build confidence in measurement accuracy and acquired data Equipment cali...

Page 3: ...warranty against defective material and workmanship for a period of one year from date of original purchase Contact PCB for a complete statement of our warranty Expendable items such as batteries and...

Page 4: ...erations 3 6 0 CALIBRATION 3 6 1 Calibration Certificate Description 3 6 1 1 Measured Output 3 6 1 2 Hysteresis 4 6 1 3 Best Fit Output 4 6 1 4 Strain Gage Measurements 4 6 1 5 Shunt Calibration Stand...

Page 5: ...50 lbf to 5k lbf 3 1 Dimensions 4 0 MECHANICAL INSTALLATION Loads applied to S type load cells must be even and centered Compensation linkages e g rod end bearing alignment couplers are recommended to...

Page 6: ...or noisy signals A simple test with a voltmeter connected between the power cord ground and the structure on which the load cell is mounted can confirm that the structure has been properly grounded I...

Page 7: ...cision shunt resistor is 60 000 ohms 0 1 simulates an output of approximately 73 of the full scale output for the load cell The calibration values for each bridge are found on the calibration certific...

Page 8: ...aboratory in Farmington Hills Michigan is A2LA Accredited per ISO IEC 17025 Standard calibration certificates list five force points ascending and one point descending Additional data points are avail...

Page 9: ...104 g Mounting Thread 1 4 28 thread No Metric Equivalent Housing Material Aluminum Aluminum Sensing Element Strain Gage Strain Gage Deflection at Full Scale Capacity 0 002 in 0 05 mm Electrical Conne...

Page 10: ......

Reviews: