background image

 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 

 

 

 

 

PCB

业监视和测量设备

 - 

中国

RoHS2

公布表

 

PCB Industrial Monitoring and Measuring Equipment - China RoHS 2 Disclosure Table 

部件名称

 

有害物

 

 (Pb) 

 

(Hg) 

 

(Cd) 

六价

 (Cr(VI)) 

多溴

联苯

 (PBB) 

多溴二苯

 (PBDE) 

住房

 

PCB

 

电气连接

 

压电晶

 

 

铁氟龙

 

 

厚膜基板

 

电线

 

电缆

 

塑料

 

 

铜合金

/

 

本表格依据

 SJ/T 11364 

规定编制

 

O

 

表示

该有害物质在该部件所有均质材料中的含量均在

 GB/T 26572 

规定的限量要求以下

 

X

 

表示

该有害物质至少在该部件的某一均质材料中的含量超出

 GB/T 26572 

规定的限量要求。

 

铅是欧洲

RoHS

指令

2011/65/ EU

附件三和附件四目前由于允

许的豁免

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CHINA RoHS COMPLIANCE 

 

 

 

 

Summary of Contents for 1402-13ADB

Page 1: ...LOAD CELL DUAL BRIDGE Installation and Operating Manual For assistance with the operation of this product contact PCB Piezotronics Inc Toll free 800 828 8840 24 hour SensorLine 716 684 0001 Fax 716 68...

Page 2: ...repair User servicing or repair is not recommended and if attempted may void the factory warranty Calibration Routine calibration of sensors and associated instrumentation is recommended as this helps...

Page 3: ...ry customer service representative Warranty All equipment and repair services provided by PCB Piezotronics Inc are covered by a limited warranty against defective material and workmanship for a period...

Page 4: ...isclosure Table Pb Hg Cd Cr VI PBB PBDE O O O O O O PCB X O O O O O O O O O O O X O O O O O O O O O O O O O O O O O O O O O O O O O X O O O O O O O O O X O O O O O O O O O O O X O O O O O X O O O O O...

Page 5: ...e O O X O O O Wires O O O O O O Cables X O O O O O Plastic O O O O O O Solder X O O O O O Copper Alloy Brass X O O O O O This table is prepared in accordance with the provisions of SJ T 11364 O Indica...

Page 6: ...6 in x 3 50 in 153 90 mm x 88 90 mm 8 Weight 21 lb 9 53 kg Mounting Thread 1 14 UNS 3B No Metric Equivalent Sensing Element Strain Gage Strain Gage Mounting Torque 1400 in lb 158 Nm Deflection at Full...

Page 7: ...10 3 12X THRU n5 125 130 2 B C 1 14UNS 3B x1 37 34 8 45 90 n2 59 65 8 1 75 44 5 n6 06 153 9 81 20 6 1 63 41 4 CONNECTOR A PTO2A 10 6P CONNECTOR WIRING CODE TYPICAL PIN A EXC PIN B SIG PIN C SIG PIN D...

Page 8: ...LECTRICAL INSTALLATION 5 5 1 Electrical Drawing Western Regional Std 5 5 2 Cable Grounding Considerations 5 6 0 CALIBRATION 5 6 1 Calibration Certificate Description 5 6 1 1 Measured Output 6 6 1 2 Hy...

Page 9: ...the parts under test have completed the planned fatigue test cycles 3 0 OVERVIEW Dual bridge fatigue rated load cells are specifically designed for repetitive testing Applications include material te...

Page 10: ...ote that the performance of the load cell may be affected if the factory installed mounting base is removed or modified 4 2 Mounting Load Cell to a Standard Base or Custom Fixture If the load cell is...

Page 11: ...ctor Protector 1 Remove the 4 40 x 1 4 button head cap screws from the connector using a 1 16 hex wrench as shown in Figure 7 2 Carefully pull the connector from the load cell Take care to not break o...

Page 12: ...wiring may result in unstable or noisy signals A simple test with a voltmeter connected between the power cord ground and the structure on which the load cell is mounted can confirm that the structur...

Page 13: ...s are adjusted such that the error due to eccentric loading is less than 0 1 per inch of offset Side loads moments and torque must be limited to avoid electrical or mechanical damage to the load cell...

Page 14: ...tion certificate and adjust the span or gain until the display reads the force value stated on the certificate 4 Repeat steps 1 3 to verify that a valid calibration setting has been obtained 5 If poss...

Page 15: ...ridge resistances A D excitation and B C the signal leads 9 Check bridge balance 10 Keep a record of your observations correct problems or contact PCB factory for assistance 11 2 1 Estimating Bridge B...

Page 16: ...factory for any reason For calibration services if possible a copy of the purchase order covering the requested services should be included with the returned load cell 13 0 WARRANTY Standard warranty...

Reviews: