background image

 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 

 

 

 

 

PCB

业监视和测量设备

 - 

中国

RoHS2

公布表

 

PCB Industrial Monitoring and Measuring Equipment - China RoHS 2 Disclosure Table 

部件名称

 

有害物

 

 (Pb) 

 

(Hg) 

 

(Cd) 

六价

 (Cr(VI)) 

多溴

联苯

 (PBB) 

多溴二苯

 (PBDE) 

住房

 

PCB

 

电气连接

 

压电晶

 

 

铁氟龙

 

 

厚膜基板

 

电线

 

电缆

 

塑料

 

 

铜合金

/

 

本表格依据

 SJ/T 11364 

规定编制

 

O

 

表示

该有害物质在该部件所有均质材料中的含量均在

 GB/T 26572 

规定的限量要求以下

 

X

 

表示

该有害物质至少在该部件的某一均质材料中的含量超出

 GB/T 26572 

规定的限量要求。

 

铅是欧洲

RoHS

指令

2011/65/ EU

附件三和附件四目前由于允

许的豁免

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CHINA RoHS COMPLIANCE 

 

 

 

 

Summary of Contents for 130A24

Page 1: ...Microphone Installation and Operating Manual For assistance with the operation of this product contact PCB Piezotronics Inc Toll free 800 828 8840 24 hour SensorLine 716 684 0001 Fax 716 684 0987 E ma...

Page 2: ...ty regimen When in doubt about a calibration cycle a good rule of thumb is to recalibrate on an annual basis It is also good practice to recalibrate after exposure to any severe temperature extreme sh...

Page 3: ...rchase Order should include authorization to proceed and return at current pricing which can be obtained from a factory customer service representative Contact Information International customers shou...

Page 4: ...isclosure Table Pb Hg Cd Cr VI PBB PBDE O O O O O O PCB X O O O O O O O O O O O X O O O O O O O O O O O O O O O O O O O O O O O O O X O O O O O O O O O X O O O O O O O O O O O X O O O O O X O O O O O...

Page 5: ...e O O X O O O Wires O O O O O O Cables X O O O O O Plastic O O O O O O Solder X O O O O O Copper Alloy Brass X O O O O O This table is prepared in accordance with the provisions of SJ T 11364 O Indica...

Page 6: ...brators etc you will ensure years of trouble free usage If after reading this manual you have additional questions concerning the Microphone or its application feel free to call a factory Application...

Page 7: ...They utilize low impedance cable on which signals can be driven long distances with minimal signal loss 3 0 Powering All ICP powered microphones require correct constant current excitation for proper...

Page 8: ...adout device This is a standard Coaxial cable with BNC connectors on each end PCB offers these cables in a variety of lengths for any application Figure 3 All of the 130 series Array Microphones are t...

Page 9: ...icrophone housing to remove any moisture or debris Apply the replacement water resistant patch to the end of the housing keeping it centered Finally assemble the grid cap back onto the housing Optiona...

Page 10: ...mV Pa Reference Freq 250 Hz 26 4 dB re 1V Pa Output Bias 8 6 VDC Temperature 71 F 22 C Relative Humidity 50 Condition of Unit As Found n a As Left New Unit In Tolerance Notes 1 This method involves co...

Page 11: ...ic instrumentation needs with a PCB Application Engineer 7 0 Warranty All equipment and repair services provided by PCB Piezotronics Inc are covered by a limited warranty against defective material an...

Page 12: ...dance 52 Ohm 52 Ohm Physical Housing Material Stainless Steel Stainless Steel Electrical Connector Output BNC Jack BNC Jack Size Diameter x Length overall 52 in x 2 75 in 13 2 mm x 69 9 mm Weight 1 8...

Page 13: ...FILLETS AND RADII 0 07 0 13 OUTLINE DRAWING 59447 1 OF 1 2X MODEL 130A24 DECIMALS XX 03 XXX 010 DECIMALS X 0 8 XX 0 25 BB 5 4 15 ECB 5 4 15 DRK 5 4 15 bbehringer 12 46 5 4 2015 59447 PCB Piezotronics...