PCB Piezotronics 1203-14A Installation And Operating Manual Download Page 7

 

PCB Load & Torque, Inc.   

 Toll-Free in USA 866-684-7107   

 716-684-0001   

 www.pcbloadtorque.com

 

 

 

GENERAL PURPOSE LOW PROFILE LOAD CELL OPERATION MANUAL 

 

2

 

1.0 INTRODUCTION 

 
General purpose low profile load cells manufactured by PCB 
Load & Torque, Inc. are suitable for a wide range of general 
force measurement applications, including weighing, 
dynamometer use, and static material test machines.  These 
load cells are designed for use in compression and tension 
loading, while being resistant to extraneous bending and side 
loading forces.   
 
In addition to our general purpose load cells, we offer a 
complete line of fatigue-rated load cells which are specifically 
designed for highly cyclic testing.  Applications include 
material testing, component life cycle testing, and structural 
testing.  All fatigue-rated load cells are guaranteed against 
fatigue failure for 100 million fully reversed cycles, and are 
extremely resistant to extraneous bending and side loading 
forces. 
 
The nominal full scale output of the general purpose low 
profile load cells is 4.0 mV/V for non-fatigue-rated (1200 
series) and 2.0 mV/V for fatigue-rated (1400 series). 
 
The  following  document  explains  how  to  properly  install  the 
low  profile  load  cell,  including  detailed  procedures  on 
specified  torques  installation,  adapter  thread  class  3  and 
tension pre-load specifications. 

 

2.0 SAFETY PRECAUTIONS 

 
Failure of the load cell structure or fasteners  used in the load 
cell  installation  may  cause  personal  injury  and  equipment 
damage. 
 
It  is  important  to  provide  adequate  clearances  and  safety 
guards  or  shields  properly  surrounding  test  fixtures  where 
fatigue rated load cells are used.   
 
It is important to review the manufactured data when selecting 
rod ends and fasteners for load cell installation. Failure might 
occur due to combine measurement axis and extraneous loads 
if installation specifications are not followed.  All test fixtures 
designed  for  use  with  low  profile  load  cells  should  be 
carefully evaluated for potential failure modes of the fixtures. 
 
It  is  important  to  use  threaded  fasteners  properly  when 
assembling test fixtures used with the load cells.  Fixtures with 
inadequately  designed  bolted  joints,  or  improperly  tightened 
threaded  fasteners  can  fail  before  the  parts  under  test  have 
completed the planned fatigue test cycles. 
 

3.0 OVERVIEW 

 
General  purpose  low  profile  load  cells  come  in  a  variety  of 
capacities to handle loads ranging from 250 lbf to 200,000 lbf. 
 

3.1 Dimensions 

The following figure and tables give the general outline 
dimensions of the general purpose low profile load cells with 
optional tension base. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Model Series 

1203/1403 

1204/1404 

1208/1408 

1211/1411 

Dimensions 

(see Figure 1) 

(in) 

(mm) 

(in) 

(mm) 

(in) 

(mm) 

(in) 

(mm) 

2.50 

63.5 

3.50 

88.9 

4.50 

114.3 

6.50 

165.1 

1.37 

34.8 

1.75 

44.5 

2.50 

63.5 

3.50 

88.9 

1.13 

28.7 

1.75 

44.5 

2.00 

50.8 

3.00 

76.2 

1.25 

31.8 

1.63 

41.4 

2.25 

57.2 

3.25 

82.6 

4.12 

104.6 

6.06 

153.9 

8.00 

203.2 

11.00 

279.4 

R

2.54 

64.6 

3.53 

89.7 

4.85* 

123.2* 

6.10* 

154.9* 

3.50 

88.9 

5.13 

130.2 

6.50 

165.1 

9.00 

228.6 

8

 

1.25 

31.8 

2.42 

61.4 

3.50 

88.9 

5.38 

136.5 

9

 

1.25 

31.8 

2.25 

57.2 

3.50 

88.9 

4.50 

114.3 

10 

45º 

30º 

22.5º 

22.5º 

11 

0.25 

6.4 

0.37 

9.4 

0.48 

12.2 

0.75 

19.1 

12 

0.03 

0.76 

0.03 

0.76 

0.03 

0.76 

0.03 

0.76 

13 

1/4-28x1 3/4 

screw 12 pt. 

Qty. 8 

3/8-24x2 1/4 

screw 12 pt. 

Qty. 12 

1/2-20x3 1/2 

screw 12 pt. 

Qty. 16 

3/4-16x4 1/2 

screw 12 pt. 

Qty. 16 

14 

5/8-18 

1 1/4-12 

1 3/4-12 

2 3/4-8 

Thread Depth 

0.88 

22.4 

1.37 

34.8 

2.12 

53.8 

2.56 

65.0 

15 

5/8-18 

1 1/4-12 

1 3/4-12 

2 3/4-8 

Thread Depth 

0.88 

22.4 

1.37 

34.8 

1.71 

43.4 

3.15 

80.0 

*Indicates dimension with connector protector. 

 

“R6” dimensions given for PT02E-10-6P connector. 

Figure 1

 

- Dimensions 

Table 2

 

– Dimension Values 

Dim. 

Description 

Total Height 

Load Cell Height 

Tension Base Height 

Load Cell Body 

Height 

Load Cell Diameter 

R

Max. Clearance 

Radius 

Bolt Circle Diameter 

Top Loading Surface 

Diameter 

Bottom Loading 

Surface Diameter 

10 

Angle Between 

Screws 

11 

Screw Head Height 

12 

Bottom Loading 

Surface Height 

13 

Screw for Tension 

Base 

14 

Load Cell Mounting 

Thread 

15 

Tension Base 

Mounting Thread 

 

Table 1

 

– Dimension 

Descriptions 

 

15 

 

11 

12 

 

10 

R

13 

14 

Summary of Contents for 1203-14A

Page 1: ...AD CELL Installation and Operating Manual For assistance with the operation of this product contact PCB Piezotronics Inc Toll free 800 828 8840 24 hour SensorLine 716 684 0001 Fax 716 684 0987 E mail...

Page 2: ...alized tests including sensitivity at elevated or cryogenic temperatures phase response extended high or low frequency response extended range leak testing hydrostatic pressure testing and others For...

Page 3: ...tion on particular operating steps The following symbols may be found on the equipment described in this manual This symbol on the unit indicates that high voltage may be present Use standard safety p...

Page 4: ...China RoHS 2 Disclosure Table Pb Hg Cd Cr VI PBB PBDE O O O O O O PCB X O O O O O O O O O O O X O O O O O O O O O O O O O O O O O O O O O O O O O X O O O O O O O O O X O O O O O O O O O O O X O O O O...

Page 5: ...O Wires O O O O O O Cables X O O O O O Plastic O O O O O O Solder X O O O O O Copper Alloy Brass X O O O O O This table is prepared in accordance with the provisions of SJ T 11364 O Indicates that sai...

Page 6: ...4 5 0 ELECTRICAL INSTALLATION 5 5 1 Electrical Drawing Western Regional Std 5 5 2 Cable Grounding Considerations 5 6 0 CALIBRATION 5 6 1 Calibration Certificate Description 5 6 1 1 Measured Output 6...

Page 7: ...evaluated for potential failure modes of the fixtures It is important to use threaded fasteners properly when assembling test fixtures used with the load cells Fixtures with inadequately designed bol...

Page 8: ...modified 4 2 Mounting Load Cell to a Standard Base or Custom Fixture If the load cell is to be mounted to a custom base or fixture it is necessary to consider the following 1 The thickness of the new...

Page 9: ...f Connector Protector 1 Remove the 4 40 x 1 4 button head cap screws from the connector using a 1 16 hex wrench as shown in Figure 7 2 Carefully pull the connector from the load cell Take care to not...

Page 10: ...A simple test with a voltmeter connected between the power cord ground and the structure on which the load cell is mounted can confirm that the structure has been properly grounded If the power cord g...

Page 11: ...into the load cell structure The strain gage bridges on general purpose low profile load cells are adjusted such that the error due to eccentric loading is less than 0 25 per inch of offset for 1200 s...

Page 12: ...s on the load cell If possible remove all loads 2 Power up the host signal conditioner and connect it to the load cell via appropriate cable and allow for a 30 minute warm up 3 Set the load indicator...

Page 13: ...e load cell is mounted on 5 Check the signal conditioning electronics for proper setup 6 Check the insulation resistance of shielded conductors for short circuits 7 Check isolation resistance load cel...

Page 14: ...der Please request a return material authorization RMA before sending a load cell back to the factory for any reason For calibration services if possible a copy of the purchase order covering the requ...

Page 15: ...ng Element Strain Gage Strain Gage Mounting Torque 200 lbf in 23 Nm Deflection at Full Scale Capacity 0 002 in 0 05 mm Electrical Connector PT02E 10 6P PT02E 10 6P All specifications are at room tempe...

Page 16: ...LOAD CELLS 5 8 18UNF 3B METRIC M LOAD CELLS M16X2 0 4H SPECIAL LOAD CELL 1 14UNS 3B 2 50 63 5 030 76 45 THREAD x 88 22 3 STANDARD LOAD CELLS 5 8 18 UNF 3B METRIC M LOAD CELLS M16 X 2 0 4H SPECIAL LOA...

Reviews: