background image

Model 116B

Charge Output Pressure Sensor

Installation and Operating Manual

For assistance with the operation of this product,

contact PCB Piezotronics, Inc.

Toll-free: 800-828-8840

24-hour SensorLine: 716-684-0001

Fax: 716-684-0987

E-mail: [email protected]

Web: www.pcb.com

Summary of Contents for 116B

Page 1: ...re Sensor Installation and Operating Manual For assistance with the operation of this product contact PCB Piezotronics Inc Toll free 800 828 8840 24 hour SensorLine 716 684 0001 Fax 716 684 0987 E mai...

Page 2: ...alized tests including sensitivity at elevated or cryogenic temperatures phase response extended high or low frequency response extended range leak testing hydrostatic pressure testing and others For...

Page 3: ...tion on particular operating steps The following symbols may be found on the equipment described in this manual This symbol on the unit indicates that high voltage may be present Use standard safety p...

Page 4: ...China RoHS 2 Disclosure Table Pb Hg Cd Cr VI PBB PBDE O O O O O O PCB X O O O O O O O O O O O X O O O O O O O O O O O O O O O O O O O O O O O O O X O O O O O O O O O X O O O O O O O O O O O X O O O O...

Page 5: ...O Wires O O O O O O Cables X O O O O O Plastic O O O O O O Solder X O O O O O Copper Alloy Brass X O O O O O This table is prepared in accordance with the provisions of SJ T 11364 O Indicates that sai...

Page 6: ...that the sensor is supplied with optional features A option Ablative thermal barrier E option Emralon coating H option Hermetic seal J option Electrical isolation mounting adaptor required M option Me...

Page 7: ...ies 113A High Frequency Miniature Sensor The Series 113A High Frequency Miniature Sensor is a charge mode pressure sensor designed to measure shock wave blast explosion ultrasonic and dynamic combusti...

Page 8: ...rage pressure level over a wide amplitude range and a usable frequency range near DC to between 5 000 and 10 000 Hz the resonant frequency is 25 000 Hz The Model 171 is extremely sensitive with a nomi...

Page 9: ...nd L length of column feet For air at room temperature the equation becomes L 3300 Fr Where L passage length inches The natural frequency and approximately fastest pressure step rise time for various...

Page 10: ...z element The clamp nut is provided with either standard 5 16 24 or metric M7 x 0 75 threads and is supplied along with three seal rings Model 008A Hardline Cable is recommended for operating temperat...

Page 11: ...nce charge signal generated by the sensor into a low impedance voltage signal This signal may then be transmitted to a readout or recording device for analysis See Figure 5 1 for a drawing of a typica...

Page 12: ...DC offset voltage usually very tiny microvolts that exists at the input gate of the MOSFET circuit This minute leakage current exists in all real devices As demonstrated in Equation 1 the steady state...

Page 13: ...1 Introduction 6 4 Low Frequency Response Limitations In a normal charge amplifier the low frequency response is set by the RC time constant as established by the product of Cf and Rf The system acts...

Page 14: ...umulated electrostatic charges may build to the point that they may saturate or even damage the input circuitry of the charge amplifier Operate the charge amplifier in the SHORT time constant while th...

Page 15: ...se specified In the interest of constant product improvement we reserve the right tochange specifications without notice ICP is a registeredtrademarkof PCB Piezotronics Inc E Emralon coating Electrica...