background image

取扱説明書

Instruction Manual

Canon EOS R5

 

06198

MDX-R5

 

UNDERWATER HOUSING for

日本語

English

Summary of Contents for 06198

Page 1: ...取扱説明書 Instruction Manual Canon EOS R5 06198 MDX R5 UNDERWATER HOUSING for 日本語 English ...

Page 2: ... O ring E 4 Identification of Parts E 6 Preparation for Setting Up E 8 Prepare the housing and port E 8 Prepare the digital camera E 8 Prepare the connecting accessories E 8 Opening and Closing the Housing E 9 Attaching and Detaching the Port E 11 Mounting the Camera in the Housing E 13 External Controls E 15 Attaching the Optional Accessories E 18 Maintenance and Storage E 22 Specifications E 23 ...

Page 3: ...vice center for inspection Discontinue use and turn the product off immediately should you notice flooding or leakage When the product is flooding interior pressure may build up Please be careful when opening the product as water may spurt out or the cap may open explosively and cause injuries The product has been constructed with an airtight seal When packing the product for airplane travel do no...

Page 4: ...unk in summer The heat may deform plastic parts of the product damaging internal parts and resulting in potential fire or electric shock If the product is sealed tight in hot conditions heated air expanding inside the product may deform the casing and ruin the waterproofing Do not store the product in wet or high humidity place to avoid mold rust corrosion or malfunction Do not store the product w...

Page 5: ... O ring will not revert to its normal state and must be replaced If the grease is insufficient the O ring will not slide and it will become harder to open and close the waterproof parts Because of this it could become impossible to open or close the housing or it could cause flooding so please refrain from using the housing with insufficient grease Check the O ring to make sure there are no scratc...

Page 6: ... store O rings O rings last for one year Although it depends on how well they are maintained how often they are used and how they are stored O rings generally last for one year It is advisable to inspect them before use and replace them early When storing spare O rings or O rings that you have removed from the housing keep them in a cool place out of direct sunlight Also when storing O rings do no...

Page 7: ...c cable socket Connector hole Identification of Parts Rear case Front case Quick contorol dial 2 Erase button Info button AF start lever Extension connector mount Main dial Playback button LCD panel info switching Illumination button Multi function lock button Focal plane mark MODE button Main switch for Optical YS Converter AE lock button Extension connector mount M24 Setting button Quick contoro...

Page 8: ...E 7 Identification of Parts Quick shoe Leak sensor main body Pick up finder Sensor Rear case Quick shoe base Quick lock Front case ...

Page 9: ...ure the camera is operating correctly referring to the camera s instruction manual for details Prepare the connecting accessories When using external strobes lights or other accessories in combination with this product prepare the equipment before setting up If the accessories are kept watertight by O rings make sure the O rings are properly maintained If the accessories are powered by batteries m...

Page 10: ...ng Opening the locking latches With the surface of the rear case facing up press and hold the right and left locks and remove the locking latches from the hooks CAUTION When removing the locking latches be sure to use the tips of your fingers not your fingernails If you lock the locking latch after it is removed from the hook it is easier to remove the rear case ...

Page 11: ...he locking latches simultaneously CAUTION Before aligning the rear case and front case make sure there are no specks of dust scratches or deformities on the O ring and the O ring contact surfaces Check to make sure that the locking latches are securely locked Locking latch must be push down to secure a correct lock Latch catch lever to rest behind see below Not Locked Locked Push Down Lock Gap Gap...

Page 12: ...uct is delivered with a housing body cap attached to the port mount Make sure to remove the housing body cap when attaching the port The housing body cap has no watertight capability When attaching the port to the housing always refer to the instruction manual provided Before attaching the port make sure there are no specks of dust scratches or deformities on the O ring and the O ring contact surf...

Page 13: ... digit part numbers and black bayonets with this model it is necessary to modify the port s bayonet NX 90PRO ports with 5 digit part numbers and gray bayonets can be used as is For details please contact SEA SEA or a SEA SEA authorized dealer Set the port lock to the position 1 2 Hold the front case firmly and rotate the port in a counterclockwise direction Detaching the port CAUTION ...

Page 14: ...the front case 5 Using the included attachment tool fix the quick shoe to the camera s tripod socket 2 Attach the lens to the camera and then set the focus mode AF or MF 3 To prevent focus zoom control inside front case from obstructing the lens gear slide the camera into place as you pull the focus zoom dial outward Rotate the quick lock in the OPEN direction and then remove the quick shoe from t...

Page 15: ...he Housing P E 10 After the camera is mounted in the housing make sure to check that all of the housing s control parts work properly and the camera functions correctly CAUTION CAUTION If you find the fix screws are too tight use a coin or similar object to loosen the screws 1 Open the locking latches 2 Remove the rear case 3 Set the quick lock to the OPEN position 4 Slide the camera toward you as...

Page 16: ...l the focus zoom dial out and rotate it so that the convex part of the dial is set in the deep groove on the spacer When shooting with a focus zoom gear for RF Lens CAUTION The focus zoom dial cannot be used if there is no gear mounted on the lens When using a zoom gear you cannot shoot with manual focus Pull the focus zoom dial out and rotate it so that the convex part of the dial is set in the s...

Page 17: ...ck that all of the housing s control parts work properly and the camera functions correctly before underwater use Other control parts on the housing correspond to the operation parts of the digital camera Refer to the camera s instruction manual for details of each function Push the lever to operate them AF Start lever Movie Shooting lever MFN lever ...

Page 18: ...humidity direct sunlight or extreme cold Do not store the product with naphthalene or camphor mothballs or in locations such as a laboratory where chemicals are used This environment can cause mold rust corrosion or malfunction Always remove batteries from the product after use Set the battery When inserting or replacing the battery wipe off moisture on the leak sensor thoroughly and make sure tha...

Page 19: ...will be able to try various shooting techniques Lenses strobes and other accessories have different depth rating Check the depth rating for each before use Read the instruction manual for each accessory before use MDX R dedicated housing built in YS converter A built in converter can be attached to this product as an option Sync connector Cord When the Optical YS converter C is used remove the 2 p...

Page 20: ...m entering in 1 CAUTION Before inserting the fiber optic cable check to make sure that there are no scratches or dirt on the connector surface Scratches or dirt may cause the strobe to malfunction To protect the surface from scratches or dirt do not remove the caps from the fiber optic cable sockets when the cable is not inserted There is no possibility of water leaking from the fiber optic cable ...

Page 21: ...m 29511 or Hot Shoe Arm 29501 or SA8 Ball Base for Accessory Shoe 22120 The max weight of an accessory that can be mounted to the accessory shoe is approx 1050g 26 3oz Remove the accessories from the accessory shoe when carrying the housing out of water When attaching the accessories to the accessory shoe always refer to the instruction manual provided ...

Page 22: ...he finder lens When replacing the pick up finder always refer to the instruction manual provided CAUTION Some vignetting occurs When the VF45 and VF180 1 2x is mounted on housing the corners of the camera s viewfinder cannot be viewed due to vignetting When replacing the finder unit always refer to the instruction manual provided Replacing the finder Unit The optional VF45 1 2x 46111 or VF120 1 2x...

Page 23: ...fore opening the housing and avoid any water drops inside the housing After using the product maintain the O rings before storing Examine the O rings before and after each dive We recommend early exchange of the O rings at least once a year Every two years we recommend a complete overhaul of O rings regardless of the frequency in use for the best performance of the product After each use in salt w...

Page 24: ...t aluminum Depth rating 100 m 330 feet Weight Approx 2900 g 6 4 lbs housing only Dimensions Approx 345 W 173 H 164 D mm 13 5 6 8 6 4 inches Accessories Silicone grease O ring remover Hex wrench 6mm for grip dismounting Hex wrench 4mm for Lanyard bolt O ring maintenance manual QR code CR1623 lithium battery for leak sensor Attached accessories to the product Housing body cap Fiber optic cable socke...

Page 25: ...nt as of Dec 2020 シーアンドシー株式会社 145 0062 東京都大田区北千束1 4 6 TEL 03 5701 5533 カスタマーサービスセンター TEL 03 6421 1566 http www seaandsea co jp SEA SEA Co Ltd 1 4 6 Kitasenzoku Ohta ku Tokyo Japan 145 0062 TEL 81 3 5701 5533 http www seaandsea jp ...