Payne PA13NAZ Product Data Download Page 1

PA13NAZ

Product Data

DUCTED CONDENSING UNITS

Sizes 018 To 060

1.5 To 5 Nominal Tons

A08379

INDUSTRY LEADING

FEATURES / BENEFITS

Energy Efficiency

S

13 -- 14.5 SEER/ 11 -- 12 EER

Sound

S

Levels as low as 70 dBA

Design Features

S

Small footprint, same as old model and “stackable”

S

All steel cabinet construction

S

Baked on powder paint

S

Mesh coil guard

Reliability, Quality and Toughness

S

Scroll compressor

S

Factory--supplied filter drier

S

High pressure switch

S

Line lengths up to 250 ft (76 m)

S

Low ambient operation (down to --20

_

F/--28.9

_

C) with

low ambient accessories.

Summary of Contents for PA13NAZ

Page 1: ...evels as low as 70 dBA Design Features S Small footprint same as old model and stackable S All steel cabinet construction S Baked on powder paint S Mesh coil guard Reliability Quality and Toughness S...

Page 2: ...er in mm 18 457 18 457 24 610 24 610 24 610 24 610 No Blades 3 3 3 3 3 3 Motor hp w 1 8 93 1 8 93 1 4 187 1 4 187 1 4 187 1 4 187 OUTDOOR COIL Face Area sq ft 5 8 7 3 12 1 12 1 14 1 14 1 No Rows 2 2 2...

Page 3: ...50 250 250 250 250 250 230 160 060 AC with R 410A 3 8 3 8 250 250 250 225 190 150 110 Maximum actual length not to exceed 200 ft 61 m Total equivalent length accounts for losses due to elbows or fitti...

Page 4: ...Level Outdoor Below Indoor Outdoor Above Indoor 1 4 No accessories needed within allowed lengths No accessories needed within allowed lengths 175 53 3 5 16 120 36 6 50 15 2 vertical or 120 36 6 total...

Page 5: ...inter Start Kit for low ambient X X X X X X KSACY0101AAA Cycle Protector X X X X X X KSAHS1501AAA Hard Start Kit X X X X X X KSASH1801COP Sound Blanket X X X X KSASH0601COP Sound Blanket X X KSALA0401...

Page 6: ...intains condensing temperature at 100_F 10_F 37 8_C 5 5_C Usage Guideline A Low Ambient Controller must be used when cooling operation is used at outdoor temperatures below 55_F 12 8_C Suggested for a...

Page 7: ...ical Code RLA Rated Load Amps compressor NOTE Control circuit is 24 V on all units and requires external power source Copper wire must be used from service disconnect to unit All motors compressors co...

Page 8: ...7 16 6 1 2 200 223 A X O X X 37 3 16 44 9 16 17 1 16 18 7 16 30 1 2 19 5 8 29 3 16 34 1 16 13 11 16 8 1 8 15 7 8 3 4 3 7 16 6 1 2 218 240 A B X O X X 43 3 16 44 9 16 17 1 16 18 7 16 30 1 2 19 5 8 35...

Page 9: ...7 206 4 403 2 19 0 87 3 165 1 90 9 101 4 PA13AZ36 A X O X X 944 6 1131 9 433 4 468 3 774 7 498 5 741 4 865 2 347 7 206 4 403 2 19 0 87 3 165 1 99 0 109 0 PA13AZ48 A B X O X X 1097 0 1131 9 433 4 468...

Page 10: ...0 3466416 PA13NAZ24 B CNPH 2417A PG9MTAV36050 A 23 400 11 5 14 0 3466417 PA13NAZ24 B CNPH 2417A PG9MTAV36075 A 23 400 11 5 14 0 3466418 PA13NAZ24 B CNPH 2417A PG9MTAV60100 A 23 400 11 5 14 0 3466419 P...

Page 11: ...AZ30 A CNPH 3017A PG9MXA036080 28 800 11 5 14 0 3095439 PA13NAZ30 A CNPH 3017A PG9MXA048080 28 800 11 5 14 0 3092111 PA13NAZ30 A CNPH 3017A TDR 28 800 11 0 13 0 3092119 PA13NAZ30 A CNPH 3617A PG8 EA04...

Page 12: ...13 5 3092175 PA13NAZ36 A CNPH 3617A PG9MTAV36075 A 33 200 11 5 14 0 3092176 PA13NAZ36 A CNPH 3617A PG9MTAV60100 A 33 400 11 5 14 0 3092177 PA13NAZ36 A CNPH 3617A PG9MTAV60125 A 33 400 11 5 14 0 30954...

Page 13: ...PA13PAZ36 A CAP 3619A PG9MTAV36075 A 33 400 11 5 14 0 3092223 PA13PAZ36 A CAP 3619A TDR 33 400 11 0 13 0 3092216 PA13PAZ36 A CAP 3621A PG8 EA048090 33 400 11 5 14 0 3092217 PA13PAZ36 A CAP 3621A PG8 E...

Page 14: ...36060 34 000 12 0 14 5 3095738 PA13PAZ36 A CSPH 4212A PG9MXA036080 34 000 12 0 14 5 3095739 PA13PAZ36 A CSPH 4212A PG9MXA048080 34 000 12 0 14 5 3095740 PA13PAZ36 A CSPH 4212A PG9MXA060100 34 000 11 5...

Page 15: ...2321 PA13EAZ36 A CSPH 3612A PG9MTAV36075 A 33 400 11 5 14 0 3092322 PA13EAZ36 A CSPH 3612A PG9MTAV60100 A 33 400 11 5 14 0 3092323 PA13EAZ36 A CSPH 3612A PG9MTAV60125 A 33 400 11 5 14 0 3095670 PA13EA...

Page 16: ...A PG8 EA060135 47 000 12 0 14 5 3466526 PA13NAZ48 B CNPH 6124A PG9MTAV60100 A 47 000 11 5 14 0 3466527 PA13NAZ48 B CNPH 6124A PG9MTAV60125 A 47 000 11 5 14 0 3466523 PA13NAZ48 B CNPH 6124A PG9MXA04808...

Page 17: ...0 11 5 14 0 3466605 PA13PAZ48 B CNPH 4821A PG9MTAV60100 A 46 500 11 5 14 0 3466606 PA13PAZ48 B CNPH 4821A PG9MTAV60125 A 46 500 11 5 14 0 3466602 PA13PAZ48 B CNPH 4821A PG9MXA048080 46 500 11 5 14 0 3...

Page 18: ...66672 PA13EAZ48 B CAP 4823A TDR 47 000 11 0 13 0 3466661 PA13EAZ48 B CAP 4824A PG8 EA060135 46 500 11 5 14 0 3466663 PA13EAZ48 B CAP 4824A PG9MTAV60125 A 46 500 11 5 14 0 3466662 PA13EAZ48 B CAP 4824A...

Page 19: ...14 0 3466745 PA13EAZ48 B CSPH 6012A PG9MTAV60100 A 47 000 11 5 14 0 3466746 PA13EAZ48 B CSPH 6012A PG9MTAV60125 A 47 000 12 0 14 5 3466742 PA13EAZ48 B CSPH 6012A PG9MXA048080 47 000 12 0 14 5 3466743...

Page 20: ...3 PA13PAZ60 B CNPV 6124A TDR 56 000 11 0 13 0 3466821 PA13PAZ60 B CSPH 6012A PG8 EA048090 56 000 11 0 13 2 3466822 PA13PAZ60 B CSPH 6012A PG8 EA060110 56 000 11 0 13 5 3466823 PA13PAZ60 B CSPH 6012A P...

Page 21: ...Seasonal Energy Efficiency Ratio TDR Time Delay Relay In most cases only 1 method should be used to achieve TDR function Using more than 1 method in a system may cause degradation in performance Use...

Page 22: ...6 00 12 11 1 74 14 93 11 70 1 96 13 78 11 25 2 20 72 22 2 20 74 10 71 1 19 19 68 10 32 1 35 18 59 9 93 1 53 17 49 9 54 1 73 16 32 9 13 1 95 15 05 8 69 2 18 675 57 13 9 17 71 17 71 1 24 16 96 16 96 1 4...

Page 23: ...Y POWER FURNACE MODEL CNPV 2414A 1 00 1 00 CAP 2414A 1 00 1 00 CAP 2417A 1 00 1 00 CAP 3014A 1 01 1 01 CAP 3017A 1 01 1 01 CNPF 2418A 1 00 1 00 CNPH 2417A 1 00 1 00 CNPH 3017A 1 01 1 01 CNPV 2417A 1 0...

Page 24: ...1 00 CNPV 3617A 1 01 1 01 CNPV 3621A 1 01 1 01 CSPH 3012A 1 00 1 00 CSPH 3612A 0 99 0 99 FF1ENP030 0 99 0 99 FF1ENP036 1 01 1 01 PF4MNA030 0 99 0 99 PF4MNA031 1 00 0 92 PF4MNA036 1 01 1 01 PF4MNA037...

Page 25: ...4217A 1 00 0 92 PG9MXA036080 CSPH 3612A 0 98 0 94 PG9MXA036080 CSPH 4212A 1 00 0 92 PG9MXA036080 CAP 3614A 0 98 0 98 PG8 EA024045 CNPH 3617A 0 98 0 98 PG8 EA024045 CNPH 4221A 0 99 0 95 PG8 EA024045 C...

Page 26: ...8 EA048070 CSPH 6012A 1 00 1 00 PG8 EA048070 CAP 4821A 0 99 0 95 PG8 EA048090 CAP 4823A 0 99 0 95 PG8 EA048090 CAP 6021A 1 00 0 92 PG8 EA048090 CNPH 4821A 0 99 0 95 PG8 EA048090 CNPH 6024A 1 00 0 92 P...

Page 27: ...0 CNPH 6124A 1 00 1 00 CNPV 6124A 0 98 0 98 CSPH 6012A 1 00 1 00 PF4MNA060 1 00 1 05 PF4MNA061 1 01 1 01 CAP 6021A 0 98 0 98 PG8 EA048090 CNPH 6024A 0 98 0 98 PG8 EA048090 CNPH 6124A 0 98 0 98 PG8 EA0...

Page 28: ...phase type with class B insulation and permanently lubricated bearings Shafts will be corrosion resistant Fan blades will be statically and dynamically balanced Condenser fan openings will be equippe...

Page 29: ...3 4 m and or 35 ft 10 7 m vertical differential consult Residential Piping and Longline Guideline and Service Manual available from equipment distributor 6 If any refrigerant tubing is buried provide...

Page 30: ...rris St S Indianapolis IN 46231 Manufacturer reserves the right to change at any time specifications and designs without notice and without obligations Catalog No SS PA13NAZ 03 Replaces SS PA13NAZ 02...