Page 4
11V DC
14V DC
80 mA
24V DC
4 A
1
10,000
50
3,000
1
3
1
2
1
3
-20 °C
+55 °C
71 mm
70 mm
23 mm
200 mm
200 mm
75 mm
Voltage
Switchable current
Relay switchable voltage
Specifications
Operating temperature
Electrical
Environment
Dimensions
Min
Max
Width
Height
Depth
Current
NO - If used externally, it must be protected in a plastic weatherproof housing
Features
Number of Codes
Code length
Door open time
Readers per interface
Time zones (with additional time clock)
Silent operation
Can be used with fail OPEN locks
Can be used with fail CLOSED locks
Exit button input
Door Contact input
Alarm/bell output voltage
Waterproof
Number of Users
Access levels (Colour Zones)
1 - How to reset the controller.
Q
- See Main Text
2 - Two readers on the same controller.
Q
Simply wire the PROXIMITY or CARDLOCK readers in parallel, colour for colour. It is possible to mix 5V
Q
and 12V readers. The jumper on the Switch2 must be set to provide 5V at the Red terminal and the
Q
12V reader must then be powered directly from the 12V terminal.
3. - Replacing a white labelled control unit. (pre 2004 design)
Q
On a White labelled unit the Red voltage terminal output was 5V DC. The new Yellow labelled unit has
Q
this output set to 12V DC. For systems where 5V readers/keypads are to be used, readers must not be
Q
connected to yellow label controllers until the jumper setting has been changed on the controller PCB.
Q
NOTE: The Touchlock membrane keypad is not compatible with this control unit.
4 - Initialising with 2 keypads.
Q
Either Keypad can be used to initialise the controller when using K-Series Keypads. Connect all wires in
Q
parallel, colour for colour. If you are using the older Touchlock/SS then you must use the master keypad
Q
which has the yellow wire connected to yellow terminal. (The slave keypad will have the yellow wire
Q
connected to the mauve terminal.)
5 - Bell/Alarm Output.
Q
A 12V DC alarm sounder can be wired between the 12V and Bell terminals. This output is capable of
Q
driving a 12V bell/buzzer up to 1A. This load must be taken into consideration when selecting a suitable
Q
rated power supply. If door contacts are fitted on a Switch2 system, across the Black and Contacts
Q
terminals, the bell/alarm output is activated when the door is forced. On a Switch2 system using a
Q
keypad, the bell would normally activate this output. However, when using a door forced alarm, the bell
Q
on a keypad will not activate the bell/buzzer connected to this output.
Here is the list of topics about this product that receive the most technical support enquiries.
We list them here to help you speed up the installation and trouble shooting process.
Min
Max
Min
Max
Control Unit
Plastic Cabinet
Technical Help
Number of PIN's
Yes
4 digits
8 digits
60 secs
1 sec
Yes
Yes
Yes
Yes
Yes