Paxton Switch2 Quick Start Manual Download Page 1

Page 1

R

eader or K

eypad

D

oor r

ela

y

Power

Alar

m

12V

Red LED

Amber LED

Bell

12V

0V

N.C.

N.O.

COM

Green LED

Data

Caution: 

 F

or 
12V

 d.c readers only

 F

or 
correct 

connection 

of 
old 5V

 readers, 

please ref

er 

to 
instructions.

Clock

Exit

Inputs

Contact

Media Detect

0V

PLACE SERIAL

NUMBER

LABEL HERE

Switch2

http://paxton.info/107

123456

Quickstart guide

This supplement is a brief guide to installing a Switch2 system.  Further information is available for download at:  

http://paxton.info/45

 or call the communications team on:

  01273 811011.

Exit button

Black/0V and Exit

(push to make)

Reader

Fail closed release

(for Paxton exit buttons 

GREEN and RED wires go 

to reader terminals)

Fail open locks

For a fail open lock (Maglock), wire 0V to the "N.C." terminal instead of "N.O."

22/01/2013

*

This product is not suitable for retail sale.  All warranties are invalid if this product is not installed by a competent person. 

Wiring

Ins-30010 Switch2 control unit

Technical Support

Technical help is available:     Monday - Friday from 07:00 - 19:00 (GMT)

                                 Saturday from 09:00 - 13:00 (GMT)

01273 811011

[email protected]

Documentation on all Paxton products can be found on our website - http://www.paxton.co.uk/

To change a reader port voltage to 5V,  move the red jumper(s) located beneath the wiring label to the 5V setting.

Paxton

Summary of Contents for Switch2

Page 1: ...ck 0V and Exit push to make Reader Fail closed release for Paxton exit buttons GREEN and RED wires go to reader terminals Fail open locks For a fail open lock Maglock wire 0V to the N C terminal instead of N O 22 01 2013 This product is not suitable for retail sale All warranties are invalid if this product is not installed by a competent person Wiring Ins 30010 Switch2 control unit Technical Supp...

Page 2: ...w barred Present swipe user s shadow card 6 digit Programming Code Adding an additional Proximity card pack You need to be in possession of a valid enrolment card for this system Present this enrolment card to the reader and the Amber LED will flash with the Green Red LED s off Present the Enrolment card from the new card pack The reader will beep and all LED s will be lit The additional cards wil...

Page 3: ... available ii Set up the required operating mode as follows iii Present enrolment card Card plus PIN A card requires a 4 digit PIN to be assigned to it before it will work as follows Present enrolment card Present user card Enter PIN Re Enter PIN Card plus Code Access is granted by presenting a valid token and then entering a valid user code Card or Code Access is granted by presenting a valid tok...

Page 4: ... not be Qconnected to yellow label controllers until the jumper setting has been changed on the controller PCB QNOTE The Touchlock membrane keypad is not compatible with this control unit 4 Initialising with 2 keypads QEither Keypad can be used to initialise the controller when using K Series Keypads Connect all wires in Qparallel colour for colour If you are using the older Touchlock SS then you ...

Reviews: