![PAW SolarBloC maxi Basic DN 25 Installation And Commissioning Instructions Download Page 8](http://html.mh-extra.com/html/paw/solarbloc-maxi-basic-dn-25/solarbloc-maxi-basic-dn-25_installation-and-commissioning-instructions_764058008.webp)
3 Mounting and installation [specialist]
8
9976x0210x-mub-en – V01
2020/09
3.
Copy the dimension of the mounting holes of the
solar station on the mounting surface (see arrows).
4.
Drill the holes and mount the solar station to the wall
with appropriate wall plugs and screws.
5.
Connect the solar station to the installation
by using the pipes:
①
Return to the collector field
③
Return from the storage tank
All thread connections have ¾" internal threads.
6.
In order to prevent unwanted circulation, it is
mandatory to mount an additional check valve ④
in the flow on site.
Optionally available!
7.
Connect the pipe for the expansion tank below
the pressure gauge [1.5] and fix the bracket for
the expansion tank.
8.
Adapt the initial pressure of the expansion tank to the
installation and connect the expansion tank. Observe
the separate instructions for the expansion tank!
9.
Check all screw connections and tighten them if
necessary.
The assembly of the solar station is now completed
and the station can be put into operation.