52
Reading voltage
The indicator lights show the voltage at the output terminals of the energizer.
When first connected to the battery (and the Selector switch is set off), all the indicator lights
illuminate for a period of two seconds. Thereafter, if any other mode positions are selected, the
indicator lights display the output voltage at each pulse.
This indicates that the energizer is operating normally.
Each indicator light segment represents an increment of approximately 1 kV (1000 V) of
output voltage. For example, if the first four Indicator light segments are illuminated at each
pulse, the output voltage is approximately 4 kV (4000 V).
If you see only red lights at each pulse and no green lights, your fence line is very heavily
loaded, and you will need to look for faults on the fence line.
Battery indicator test setting
When the energizer is connected to a battery and the Selector switch is set to
Battery indicator ( ) the indicator lights show the charge level of the battery for a period of
30 seconds.
2kV
1kV
3kV
4kV
5kV
red
green
Indicator lights
12.
!
!
!!
The indicator lights do not display the output voltage for the first
30 seconds if the energizer is set to Battery indicator.
If five Indicator light segments are illuminated, the output voltage may
be more than 5 kV (5000 V).
Mounting Instructions