1. Configure IP address
33
OnSite Model 3210 User Manual
3 • Getting started with the OnSite
1. Configure IP address
Power connection and default configuration
First the OnSite VPN Router must be connected to the mains power supply with the power cable. Wait until
the
Run
LED stops blinking and lights constantly. Now the OnSite VPN Router is ready.
The factory default configuration for the Ethernet interface IP addresses and network masks are listed in
table 6
.
All Ethernet interfaces are activated upon power-up.
If these addresses match with those of your network, go to section
“2. Connect the OnSite VPN Router to the
network”
on page 35. Otherwise, refer to the following sections to change the addresses and network masks.
Connect with the serial interface
The
Console
port is wired as an EIA-561, RS-232 port. Use the included Model 16F-561 adapter and cable (see
figure 11
) between the OnSite VPN Router’s
Console
port and a PC or workstation’s RS-232 serial interface.
Activate the terminal emulation program on the PC or workstation that supports the serial interface (e.g.
HyperTerm).
Figure 11. Connecting to the terminal
Terminal emulation program settings:
•
9600 bps
•
no parity
•
8 bit
Table 6. Factory default IP address and network mask configuration
IP Address
Network Mask
Interface Ethernet 0/0 (ETH0)
172.16.40.1
255.255.0.0
Interface Ethernet 0/1 (ETH1)
192.168.1.1
255.255.255.0
Interface Ethernet 0/2 (ETH2)
x.x.x.x
x.x.x.x
Interface Ethernet 0/3 (ETH3)
x.x.x.x
x.x.x.x
Interface Ethernet 0/4 (ETH4)
x.x.x.x
x.x.x.x
Link
100M
Activity
En
et 0
IPLink VPN
Router
Run
Link
100M
Activity
En
et 1
P
ower
Console
Serial Terminal
Note
A Patton Model 16F-561 RJ45 to DB-9 adapter is included
with each IPLink Series device