Introduction
108
OnSite Model 3210 User Manual
E • OnSite 3210 Series factory configuration
Introduction
The factory configuration settings for the OnSite 3210 Series devices are as follows:
#----------------------------------------------------------------#
# 3210 Series
# R3.xx BUILDxxxxx
# 2005-01-18T00:00:00
# Factory configuration file
#----------------------------------------------------------------#
profile napt NAPT
profile dhcp-server DHCP
network 192.168.1.0 255.255.255.0
include 192.168.1.10 192.168.1.19
lease 2 hours
default-router 192.168.1.1
context ip router
interface eth0
ipaddress 172.16.40.1 255.255.0.0
use profile napt NAPT
interface eth1
ipaddress 192.168.1.1 255.255.255.0
context ip router
dhcp-server use DHCP
port ethernet 0 0
medium auto
encapsulation ip
bind interface eth0 router
no shutdown
port ethernet 0 1
medium auto
encapsulation ip
bind interface eth1 router
no shutdown