background image

 

6

 

IPLink 2800 Quick Start Guide

 

Note

 

The router’s V.35 interface is wired as a DCE. No DTE configuration is possible. If you are directly con-
necting the router’s V.35 interface to third-party equipment that cannot be configured as a DTE, you 
must use a tail-circuit cable. You can purchase a tail-circuit cable from a datacom-supply vendor. A tail-
circuit cable will cross-over the necessary V.35 signals so that the two DCE interfaces can communicate.

 

Note

 

The router’s X.21 interface is wired as a DCE. No DTE configuration is possible. The router’s X.21 inter-
face requires a cable with a male DB-15 connector.

 

For the IPLink’s T1/E1 WAN port, connect to an E1 service as follows:

 

   1.

 

Your incoming E1 connection will be either a twisted pair cable terminated with an RJ48C plug or two 

coaxial cables. (T1 is RJ48C only.)

— If an RJ48C plug, plug the cable into the RJ48C connector between the two coaxial connectors on 

the rear of the IPLink.

— If two coaxial cables, plug the coaxial cables into the RX and TX connectors on the rear of the 

IPLink. The RX is an input and the TX is an output.

 

   2.

 

The T1/E1 port default is disabled. Enable the T1/E1 port.

 

 2803/K/EUI(if-ip)[eth0]#

 

exit

 

 2803/K/EUI(ctx-ip)[router]#

 

exit

 

 2803/K/EUI(cfg)#

 

port e1t1 0 0

 

 2803/K/EUI(prt-e1t1)[0/0]#

 

no shutdown

 

 2803/K/EUI(prt-e1t1)[0/0]#

 

show port e1t1 0 0

 

 ...

 

The configuration of the enabled T1/E1 port is displayed. The defaults for the E1 are Master clocking, Line Code 
HDB3, Framing CRC4, Impedance 120 Ohms. This is for connecting to the RJ48C.
For modifying the T1/E1 port configuration, consult the 

 

IPLink Software Configuration Guide 

 

on the Patton web-

site: 

 

www.patton.com/manuals.

 

5.0  Additional information

 

For detailed information about configuring and operating guidance, set up procedures and troubleshooting, 
refer to the 

 

IPLink Getting Started Guide

 

 on the enclosed Patton CD-ROM or at 

 

www.patton.com/manuals

 

On the CD-ROM you will also find numerous freeware and shareware tools, including TFTP servers, Telnet 
clients, etc.

Summary of Contents for IPLINK 2800 series

Page 1: ...es VPN Routers Quick Start Guide Document Number 13220U7 001 Rev D Part Number 07M2800 QS Revised March 31 2006 Sales Office 1 301 975 1000 Technical Support 1 301 975 1007 E mail support patton com WWW www patton com ...

Page 2: ...epairs or repaired by qualified service personnel Mains Voltage Line voltages are present when the power cord is con nected The mains outlet shall be within 10 feet 3 meters of the device shall be easily accessible and protected by a circuit breaker For AC powered units ensure that the power cable used meets all applicable standards for the country in which it is to be installed and that it is con...

Page 3: ...68 1 1 netmask 255 255 255 0 WAN port red ETH 0 0 IP address and netmask DHCP client A DHCP server with address space 192 168 1 10 192 168 1 99 netmask 255 255 255 0 is running on the LAN ports Both Ethernet ports are pre configured and active If these addresses conflict or do not match with your network they must be changed Contact your network administrator if you are not sure which IP address t...

Page 4: ...ixed IP address as follows In this example we assume a private network since the IP address changes to 172 16 1 100 with netmask of 255 255 255 0 1 Select the context IP mode to configure an IP interface 2803 K EUI cfg context ip router 2803 K EUI ctx ip router 2 Set your IP address and network mask on the WAN IP interface eth0 Contact your network administra tor if you are not sure what IP addres...

Page 5: ... patton com 4 0 Connecting the IPLink serial port If your IPLink is equipped with a serial WAN port connect it to the appropriate DCE The IPLink 2800 Series is available with the following serial interfaces V 35 DB 25 Model 2835 X 21 DB 15 Model 2821 E1 RJ48C or dual coaxial connectors Model 2803 K T1 RJ48C Model 2803 T For the V 35 and X 21 serial ports do the following to connect the serial cabl...

Page 6: ...o coaxial connectors on the rear of the IPLink If two coaxial cables plug the coaxial cables into the RX and TX connectors on the rear of the IPLink The RX is an input and the TX is an output 2 The T1 E1 port default is disabled Enable the T1 E1 port 2803 K EUI if ip eth0 exit 2803 K EUI ctx ip router exit 2803 K EUI cfg port e1t1 0 0 2803 K EUI prt e1t1 0 0 no shutdown 2803 K EUI prt e1t1 0 0 sho...

Page 7: ...s relating to Radio and Telecommunication Terminal Equip ment and the mutual recognition of their conformity The safety advice in the documentation accompanying this product shall be obeyed The conformity to the above directive is indicated by the CE sign on the device The signed Declaration of Conformity can be downloaded from www patton com certifications The safety advises in the documentation ...

Page 8: ...5 1007 Support via VoIP Contact Patton free of charge by using a VoIP ISP phone to call sip support patton com Fax 1 253 663 5693 Alternate Patton support for Europe Middle East and Africa EMEA Telephone support Standard telephone support is available five days a week from 8 00 am to 5 00 pm CET 0900 to 1800 UTC GMT by calling 41 0 31 985 25 55 Fax 41 0 31 985 25 26 Note For additional service and...

Reviews: