background image

 

6

 

SmartNode 4960 Series Quick Start Guide

 

Note

 

Patton regularly adds new configuration templates to the collection at 

 

www.patton.com/voip

 

, so 

if you do not see your application on the CD-ROM, it may have been added to the website. 

 

Note

 

If your application is unique and not covered by any of Patton’s configuration templates, you can man-
ually configure the SmartNode instead of loading a configuration file template. In that case, refer to 
the 

 

SmartNode Series SmartWare Software Configuration Guide

 

 for information on configuring the Smart-

Node device.

 

In this example we assume an TFTP server resides on the host with the IP address 172.16.1.11 and the configu-
ration file named 

 

SN.cfg

 

 resides in the root directory of the TFTP server.

 

 172.16.1.99(if-ip)[WAN]#

 

copy tftp://172.16.1.11/SN.cfg startup-

config

 

 Download...100%
 172.16.1.99(if-ip)[WAN]#
 

 

After you reboot the SmartNode the new startup configuration will become active.

 

 172.16.1.99(if-ip)[WAN]#

 

reload

 

 Running configuration has been changed.
 Do you want to copy the 'running-config' to the 'startup-config'?
 Press 'yes' to store, 'no' to drop changes : 

 

no

 

 Press 'yes' to restart, 'no' to cancel : 

 

yes

 

 The system is going down

 

6.0  Additional Information

 

Refer to the 

 

SmartNode Series SmartWare Software Configuration Guide

 

 and the 

 

SmartNode Getting Started Guide 

 

located on the CD-ROM shipped with your SmartNode device and available online at 

 

www.patton.com/

manuals. 

 

For detailed information about:

 

 

Installing, configuring, operating, and troubleshooting.

 

 

Warranty, trademark & compliance

The CD-ROM also includes many freeware and shareware tools, including TFTP servers, and Telnet clients.

 

A.0  Customer and Technical Support

 

Toll-Free VoIP support: call 

 

sip:[email protected]

 

 with a VoIP SIP client 

Online support: www

 

.patton.com

 

E-mail support: 

 

[email protected]

 

—answered within 1 business day

 

When you issue the reload command, the SmartNode will ask if you want to copy the 
running configuration to the startup configuration. Since you just downloaded a con-
figuration file to the startup configuration you must answer this question with 

 

NO

 

Otherwise, the downloaded configuration will be overwritten and lost!

IMPORTANT

VoIPon     www.voipon.co.uk      [email protected]      Tel: +44 (0)1245 808195      Fax: +44 (0)1245 600030

Summary of Contents for SmartNode 4960 Series

Page 1: ...ment Number 13223U7 001 Rev A Part Number 07MSN4960 QS Revised June 30 2006 Sales Office 1 301 975 1000 Technical Support 1 301 975 1007 E mail support patton com WWW www patton com VoIPon www voipon...

Page 2: ...3 meters of the device shall be easily accessible and protected by a cir cuit breaker Ensure that the power cable used with this device meets all applicable standards for the country in which it is to...

Page 3: ...IP settings The factory default configuration for the Ethernet interface IP addresses and netmasks are listed in table 1 Both Ethernet interfaces are activated upon power up LAN interface ETH 0 1 LAN...

Page 4: ...rk 172 16 1 0 24 is assumed The IP address in example is set to 172 16 1 99 You should set it to the IP address that the network provider has given you Note The examples in this guide use a private IP...

Page 5: ...tion Set IP addresses in Appendix C Command Summary of the SmartNode Series SmartWare Software Config uration Guide 5 0 Loading the configuration optional Patton provides a collection of configuration...

Page 6: ...ning config to the startup config Press yes to store no to drop changes no Press yes to restart no to cancel yes The system is going down 6 0 Additional Information Refer to the SmartNode Series Smart...

Page 7: ...nstalled and used properly that is in strict accordance with the manufacturer s instructions may cause interference to radio and television reception The SmartNode router have been tested and found to...

Page 8: ...the state public utility commission public ser vice commission or corporation commission for information B 4 Industry Canada Notice This equipment meets the applicable Industry Canada Terminal Equipm...

Page 9: ...men in der von uns in Verkehr gebrachten Ausf hrung mit den Vorschriften fol gender Richtlinie berein R TTE 1999 5 EG Richtlinie des europ ischen Parlaments und des Rates zur Angleichung der Rechtsvor...

Page 10: ...their respective owners Warranty Trademark Compliance Information For warranty trademark and compliance information refer to the Models SN4960 Series Getting Started Guide located on the CD ROM that...

Page 11: ...____________ ____________________________________________________________________ ____________________________________________________________________ _________________________________________________...

Page 12: ...____________ ____________________________________________________________________ ____________________________________________________________________ _________________________________________________...

Reviews: