background image

Repairs to certified equipment should be coordinated by a

representative designated by the supplier. Any repairs or alterations
made by the user to this equipment, or equipment malfunctions, may
give the telecommunications company cause to request the user to
disconnect the equipment.

Users should ensure for their own protection that the electrical

ground connections of the power utility, telephone lines and internal
metallic water pipe system, if present, are connected together. This
precaution may be particularly important in rural areas. Caution: Users
should not attempt to make such connections themselves, but should
contact the appropriate electric inspection authority, or electrician, as
appropriate.

3

2.0 GENERAL INFORMATION

Thank you for your purchase of this Patton Electronics product.

This product has been thoroughly inspected and tested and is
warranted for One Year parts and labor. If you have any questions while
installing or using this product, please do not hesitate to contact Patton
Electronics Technical Support at (301) 975-1007. 

2.1 FEATURES

Uses a multi-stage hybrid circuit for the best possible protection

Handles surge energy up to 1.5 kW 

Conforms to the UL497A telco specification (except E1 versions) 

Available for ISDN-U (8-wire), ISDN-ST (4-wire), T1, E1, ISDN
PRI, DDS, leased line and dial up configurations

Diverts surges directly to chassis ground through braided metal
ground strap

Equipped with two RJ-45 jacks or four BNC connectors

Easy to install

Made in the U.S.A.

2.2 DESCRIPTION

The potential threats to ISDN and Telco hardware are vast:

lightning, AC power induction, electrostatic discharge, ground potential
differences, EMI/RFI interference and more. The Patton Model 552 has
been designed to greatly reduce these risks. Just attach one unit to
each of your telco ports and rest easy.

The Model 552 connects directly between twisted pair telco cables

and their respective I/O ports. Grounding is accomplished using an
external ground strap that provides a separate unit-ground to chassis-
ground connection. By shunting threatening voltages directly to chassis
ground, the Model 552 insures data integrity and protects connected
equipment from damage. 

The Model 552 uses a solid state design and sophisticated

multistage hybrid circuits to achieve maximum protection without
performance loss. Eight versions are available: Model 552-ST, 552-D8,
and 552-L8 protect all 8 pins; Model 552-D6 protects six pins; Models
552-DDS, 552-D4, 552-U, 552-L4, 552-E1, 552-E1 CX, and 552-T1
protect four pins; and, Model 552-D2 protects two pins.  All versions
provide up to 1500 Watts of data line protection.

NOTE: Model 552-L8 may be used to protect Leased Line, DDS,
T1, E1, ISDN PRI, and ISDN BRI “U” and “ST” interfaces.

WARNING!: This product will not provide complete protection
should your equipment or building be subject to a direct lightning hit.

4

Summary of Contents for MODEL 552

Page 1: ...Series High Speed Telco Surge Protectors SALES OFFICE 301 975 1000 TECHNICAL SUPPORT 301 975 1007 http www patton com Part 07M552 E Rev G Revised 01 27 10 C E R T I F I E D C E R T I F I E D An ISO 9...

Page 2: ...an acceptance of these terms by the user 1 1 SERVICE All warranty and non warranty repairs must be returned freight prepaid and insured to Patton Electronics All returns must have a Return Materials A...

Page 3: ...s causing harm to the network the telephone company may request you to remove the equipment from the network until the problem is resolved 5 Repairs are to be made only by Patton Electronics Company o...

Page 4: ...r to disconnect the equipment Users should ensure for their own protection that the electrical ground connections of the power utility telephone lines and internal metallic water pipe system if presen...

Page 5: ...ore The Patton Model 552 has been designed to greatly reduce these risks Just attach one unit to each of your telco ports and rest easy The Model 552 connects directly between twisted pair telco cable...

Page 6: ...our equipment is connected to the protected side of the Model 552 See Figure 1 below NOTE The Model 552 E1 CX has two pairs of BNC jacks that connect one to one through the device See Figure 2 below 3...

Page 7: ...ng braid Differential Mode Pins 1 2 7 8 Model 552 D2 Pins Protected Pins 4 5 on the RJ 45 Interface Pins 3 4 on the RJ 11 Interface Clamping Voltage 310 Volts in 500 nsec Surge Capacity 1500 Watts for...

Page 8: ...an 8 20 sec pulse Protection Mode Common Mode Pins 1 2 3 4 5 6 7 8 to shielding braid Differential Mode Pins 1 2 3 4 5 6 7 8 Model 552 T1 and 552 E1 Pins Protected Pins 1 2 4 5 Clamping Voltage 62 Vol...

Page 9: ...ommon Mode pins 1 2 3 4 5 6 7 8 to shielding braid Differential Mode Pins 1 2 3 4 5 6 7 8 NOTE In addition to protecting leased line modem interfaces the Model 552 L8 may also be used to protect DDS T...

Page 10: ..._________________________________ ____________________________________________________________________ ____________________________________________________________________ ____________________________...

Page 11: ..._________________________________ ____________________________________________________________________ ____________________________________________________________________ ____________________________...

Page 12: ......

Reviews: