4 • Alarms
T1/E1 DACS Administrators’ Reference Guide
34
Modify Response—Configuring the alarm response system
•
Clear Alarm—Clearing the alarm resets the alarm, resets Time Since Alarm to 0.00 seconds and resets
Alarm Count to 0 (zero).
Types of Alarms
•
Box Alarm Group
-
Box: Over Temperature—When the internal box temperature exceeds the temperature threshold under
Modify Response…
, an alarm will be generated.
-
Box: Power Supply I – II Fail—An alarm will be generated when a power supply fails.
•
WAN Alarm Group
-
WAN 1 – 4: Yellow Alarm—When a WAN port sees a yellow alarm, the specific WAN alarm will be sent.
-
WAN 1 – 4: Red Alarm—When a WAN port sends a red alarm, the specific WAN alarm will be sent.
Modify Response—Configuring the alarm response system
The alarm response outputs refer to points of external notification. Note that the front panel Alarm LED and
the web administration pages will always indicate an occurrence of an active alarm. To configure each alarm
response output, click on
Modify Response
. The Alarm Response System page appears (see figure 11). Choose
the alarm response output that you want to configure with the pull down menu. After configuring a specific
alarm response output, remember to click on
Submit Query
before going to the next alarm response output;
otherwise the change will not occur.
Relay Response
The relay may be set to go active for minor alarms, major alarms, or both. It may also be disabled with the
parameter “none.”
Minor Alarm Syslog Priority & Major Alarm Syslog Priority
When a minor/major alarm occurs, a message of the selected priority is sent to the Syslog engine. The Priority
levels are priorityDisable(100), prioritySystem(80), priorityService(60), priorityOddity(40), priorityInfo(20),
priorityDebug(10), and priorityVerbose(5). For more information on Syslog messages, refer to Chapter 16,
“System Log”.
Minor Alarm SNMP Trap IP [address] (minSyslogPriority)
Upon the occurrence of a minor alarm, an SNMP Trap message is sent to a host system (or a management sta-
tion). This parameter is the IP address of the host running the SNMP Trap daemon. When the IP address is set
to 0.0.0.0 no SNMP Trap message will be sent.
Major Alarm SNMP Trap IP [address] (majorSyslogPriority)
This parameter functions in the same manner as the Minor Alarm SNMP Trap IP [address] except it applies to
major alarms. Upon the occurrence of a major alarm, an SNMP Trap message is sent to a host system (or a
management station). This parameter is the IP address of the host running the SNMP Trap daemon. When the
IP address is set to 0.0.0.0 no SNMP Trap message will be sent.
Summary of Contents for Model 2604
Page 18: ...About this guide T1 E1 DACS Administrators Reference Guide 16...
Page 22: ...1 Introduction T1 E1 DACS Administrators Reference Guide 20 Saving HTTP HTML Object Changes...
Page 46: ...6 Clocking T1 E1 DACS Administrators Reference Guide 44 Configuring the System Clock Settings...
Page 56: ...8 Filter IP T1 E1 DACS Administrators Reference Guide 54 Defining a filter...
Page 80: ...11 TCP T1 E1 DACS Administrators Reference Guide 78 TCP Details...
Page 84: ...12 UDP T1 E1 DACS Administrators Reference Guide 82 Introduction...
Page 90: ...13 RIP Version 2 T1 E1 DACS Administrators Reference Guide 88 RIP Version 2 Statistics...
Page 96: ...14 SNMP T1 E1 DACS Administrators Reference Guide 94 Out...
Page 108: ...15 System T1 E1 DACS Administrators Reference Guide 106 System Packet Holding Message Blocks...
Page 138: ...17 T1 E1 Link T1 E1 DACS Administrators Reference Guide 136 Far End Line Statistics Totals...
Page 148: ...20 License T1 E1 DACS Administrators Reference Guide 146 End User License Agreement...