![background image](http://html2.mh-extra.com/html/patton-electronics/model-2604/model-2604_administrators-reference-manual_4078633135.webp)
Far End Line Statistics—History
133
T1/E1 DACS Administrators’ Reference Guide
17 • T1/E1 Link
Interval (dsx1FarEndIntervalNumber)
A number between 1 and 96, where 1 is the most recently completed 15-minute interval and 96 is the least
recently completed 15-minutes interval (assuming that all 96 intervals are valid).
Errored Seconds (dsx1FarEndIntervalESs)
The number of far-end errored seconds encountered by a DS1 interface in one of the previous 96, individual
15-minute, intervals.
Severely Errored Seconds (dsx1FarEndIntervalSESs)
The number of far-end severely errored seconds encountered by a DS1 interface in one of the previous 96,
individual 15-minute, intervals.
Severely Errored Frame Seconds (dsx1FarEndIntervalSEFSs)
The number of far-end severely errored framing seconds encountered by a DS1 interface in one of the previous
96, individual 15-minute, intervals.
Unavailable Seconds (dsx1FarEndIntervalUASs)
The number of far-end unavailable seconds encountered by a DS1 interface in one of the previous 96, individ-
ual 15-minute, intervals.
Controlled Slip Seconds (dsx1FarEndIntervalCSSs)
The number of far-end controlled slip seconds encountered by a DS1 interface in one of the previous 96, indi-
vidual 15-minute, intervals.
Line Errored Seconds (dsx1FarEndIntervalLESs)
The number of far-end line errored seconds encountered by a DS1 interface in one of the previous 96, individ-
ual 15-minute, intervals.
Path Code Violations (dsx1FarEndIntervalPCVs)
The number of far-end path coding violations encountered by a DS1 interface in one of the previous 96, indi-
vidual 15-minute, intervals.
Bursty Errored Seconds (dsx1FarEndIntervalBESs)
The number of far-end bursty errored seconds (BESs) encountered by a DS1 interface in one of the previous
96, individual 15-minute, intervals.
Degraded Minutes (dsx1FarEndIntervalDMs)
The number of far-end degraded minutes (DMs) encountered by a DS1 interface in one of the previous 96,
individual 15-minute, intervals.
Summary of Contents for Model 2604
Page 18: ...About this guide T1 E1 DACS Administrators Reference Guide 16...
Page 22: ...1 Introduction T1 E1 DACS Administrators Reference Guide 20 Saving HTTP HTML Object Changes...
Page 46: ...6 Clocking T1 E1 DACS Administrators Reference Guide 44 Configuring the System Clock Settings...
Page 56: ...8 Filter IP T1 E1 DACS Administrators Reference Guide 54 Defining a filter...
Page 80: ...11 TCP T1 E1 DACS Administrators Reference Guide 78 TCP Details...
Page 84: ...12 UDP T1 E1 DACS Administrators Reference Guide 82 Introduction...
Page 90: ...13 RIP Version 2 T1 E1 DACS Administrators Reference Guide 88 RIP Version 2 Statistics...
Page 96: ...14 SNMP T1 E1 DACS Administrators Reference Guide 94 Out...
Page 108: ...15 System T1 E1 DACS Administrators Reference Guide 106 System Packet Holding Message Blocks...
Page 138: ...17 T1 E1 Link T1 E1 DACS Administrators Reference Guide 136 Far End Line Statistics Totals...
Page 148: ...20 License T1 E1 DACS Administrators Reference Guide 146 End User License Agreement...