2.0  GENERAL INFORMATION

Thank you for your purchase of this Patton Electronics product.

This product has been thoroughly inspected and tested and is
warranted for One Year parts and labor. If any questions or problems
arise during installation or use of this product, please do not hesitate to
contact Patton Electronics Customer Service at (301) 975-1007.

2.1  FEATURES

•  Data rates of 32, 56 and 64 kbps
•  Distances to 6 miles (9.7km)
• Switch-selectable carrier control
• Synchronous X.21 operation 
• Frequency Shift Keying (FSK) modulation
• DCE/DTE Switchable
•  Point-to-point operation over 2 unconditioned twisted pair
• V.54 loopback tests and V.52 compliant BER tests
•  6 LED indicators
• Externally powered
• Transformer isolation
•  Silicon Avalanche Diode surge protection
•  Made in the U.S.A.

2.2  DESCRIPTION

The Model 1075 KiloModem II X.21 Short Range Modem

supports synchronous data rates of 32, 56 and 64 Kbps.  Synchronous
transmit clock options are internal, external and receive recover clock.
Deriving power from a 9V DC wall-mount transformer, the Model 1075
supports extended distances to 6 miles (9.7km) over 2 unconditioned
twisted pairs.

The Model 1075 incorporates two V.54 test modes (local analog

loop and remote digital loop) that are activated by a tiny front panel
switch. In addition, a built-in V.52 Bit Error Test (BER) test generator
that outputs 511 and 511E bit patterns can also be controlled by a
switch on the case.   Six LED indicators monitor transmit data, receive
data, control, indication, test mode (TM) and Error Status (ER).  For
protection against ground loops and transient surges, the Model 1075
incorporates both isolation transformers and Silicon Avalanche Diode
surge suppressors.

Housed in a miniature ABS plastic case, the Model 1075 comes

equipped with a female DB-15 connector and a choice of twisted pair
interfaces (RJ-11 jack or RJ-45 jack).

3.0  CONFIGURATION

The Model 1075 is easy to install and is ruggedly designed for

excellent reliability.  The following instructions will help you to properly
configure the Model 1075.

3.1  CONFIGURATION SWITCHES

The Model 1075 uses a unique set of 16 external mini DIP

switches that allow configuration to wide range of applications.  The 16
external switches are grouped into two eight-switch sets, and are
externally accessible from the underside of the Model 1075 (See Figure
1).

The two sets of DIP switches on the underside of the Model 1075

will be referred to as S1, S2.  Figure 2 shows the orientation of DIP
Switches S1 and S2 with respect to “ON” and “OFF” positions.

4

3

1

2

3

4

5

6

7

8

ON

Figure 2

.  Close-up of DIP Switches Showing “ON” / “OFF” Positions

ON

OFF

ON

1

2

3

4

5

6

7

8

ON

1

2

3

4

5

6

7

8

S1

S2

Figure 1

.  Underside of the 1075 Showing Location of DIP Switches 

Front

Rear

Summary of Contents for KiloModem II 1075

Page 1: ...Modem II AC Powered High Speed X 21 Short Range Modem SALES OFFICE 301 975 1000 TECHNICAL SUPPORT 301 975 1007 http www patton com Part 07M1075 B Doc 054081U Rev C Revised 1 23 08 C E R T I F I E D An...

Page 2: ......

Page 3: ...ontainer This number may be obtained from Patton Electronics Technical Service 301 975 1007 http www patton com or support patton com NOTE Packages received without an RMA number will not be accepted...

Page 4: ......

Page 5: ...16 external switches are grouped into two eight switch sets and are externally accessible from the underside of the Model 1075 See Figure 1 The two sets of DIP switches on the underside of the Model 1...

Page 6: ......

Page 7: ...terminal interface Off On Receive Recover System clock derived from the received line signal Switch S2 5 Carrier Control S2 5 Carrier Description Off Always On Transmitter is always ON On Follows ter...

Page 8: ......

Page 9: ...e 6 below The X 21 DCE DTE strap is located near the DB 15 connector on the PC board The arrows on the top of the strap indicate the configuration of the Model 1075 For example if the DCE arrows are p...

Page 10: ......

Page 11: ...pair interface 2 To function properly the Model 1075 needs two twisted pairs of metallic wire These pairs must be unconditioned dry metallic wire between 19 and 26 AWG the higher number gauges may li...

Page 12: ......

Page 13: ...d with the standard version of the Model 1075 is a wall mount type and may be plugged into any approved 120 VAC wall plug 230 VAC Power IEC The 230 VAC adapter supplied with the international version...

Page 14: ......

Page 15: ...nal equipment is operating properly and can be used for a test If a fault is indicated call a technician or replace the unit C Perform a Bit Error Rate BER test on each unit If the BER test equipment...

Page 16: ......

Page 17: ...terfaces CCITT ITU X 21 Data Rates 32 56 and 64 Kbps switch selectable Isolation 1500V RMS via isolation transformers Surge Protection IEC 801 S Level 2 1kV Carrier Control Constantly on or Controlled...

Page 18: ......

Page 19: ...Female Pin Signal Source 1 Shield 2 Transmit a DTE 3 Control a DTE 4 Receive a DCE 5 Indication a DCE 6 System Clock a DCE 7 8 Signal Ground 9 Transmit b DTE 10 Control b DTE 11 Receive b DCE 12 Indic...

Page 20: ......

Page 21: ......

Page 22: ......

Page 23: ......

Page 24: ...from you Please contact us in any of the following ways to tell us how you like this product and how we can meet your product needs today and in the future Web http www patton com Sales E mail sales...

Reviews: