If the BER test equipment indicates a fault, and the Local 
Analog Loopback test was successful for both Model 1075s, 
you may have a problem with the twisted pair line between the
modems.  You should then check the twisted pair line for 
proper connections and continuity.

5.2.3  How to Use the V.52 BER Test Independently

The V.52 BER test can be used independently of the V.54 loopback

tests.  This requires two operators:  one to initiate and monitor the test
at the local Model 1075, and one at the remote Model 1075.  To use the
V.52 BER test by itself, both operators should simultaneously follow
these steps:

1.

Locate the 511/511E toggle switch on the front panel of the 
1075 and move it 

UP

.  This activates the V.52 BER test mode 

and transmits a 511 test pattern to the other unit.  If any errors 
are present, the receiving modem’s red Error LED will blink 
sporadically.  For this test to work, make sure  the 511 switch 
on both Model 1075s is on.

2.  If the test indicates no errors are present, move the V.52 

toggle switch 

DOWN

, activating the 511/E test with errors 

present.  If the test is working properly, the receiving modem's 
red Error LED will blink regularly.  A successful 511/E test will 
confirm that the link is in place, and that the Model 1075’s 
built in 511 generator and detector are working properly.

5.3  POWER-DOWN

There is no power switch on the Model 1075.  You turn it off by

unplugging the AC power adapter from the wall.

APPENDIX A

PATTON MODEL 1075 SPECIFICATIONS

Approvals:

CE European Directives

DTE/DCE I/F

:

X.21 DB15F DCE or DTE, EIA RS-422 
Compliant

Compatibility:

1035, 1045 , 1075, 1080A, 1090 series units

Transmission  
Format:

Synchronous

Transmission 

Unconditioned twisted pair 19 - 26 AWG

Line Interface:

Externally accessible RJ-45 (RJ-11 
Optional)

Clock

Internal, External and Network (Receive 
Recover)

Distance:

Up to 6 miles (9.7km)

Interfaces:

CCITT/ITU X.21

Data Rates:

32, 56 and 64 Kbps (switch selectable)

Isolation:

1500V RMS via isolation transformers

Surge Protection:

IEC-801-S, Level 2, 1kV

Carrier Control 

Constantly on or Controlled by “Control” 
from DTE device (DCE mode) or 
“Indication” from DCE device (DTE mode)

Connectors:

DB-15 female
RJ-11 or RJ-45 on line side

Power Supply: 

9V DC wall-mount transformer, 200mA

Temperature 
Range:

0-60°C (32-140°F)

Altitude:

0-15,000 feet

Humidity:

5 to 95% noncondensing

Dimensions:

1.54H x4.1”W x 3.7”D 

Power Options:

120 VAC 50/60Hz, external transformer; 
230 VAC 50/60Hz, external transformer

Weight:  

2.5 lbs. (1.1 Kg)

15

16

Summary of Contents for KiloModem II 1075

Page 1: ...Modem II AC Powered High Speed X 21 Short Range Modem SALES OFFICE 301 975 1000 TECHNICAL SUPPORT 301 975 1007 http www patton com Part 07M1075 B Doc 054081U Rev C Revised 1 23 08 C E R T I F I E D An...

Page 2: ......

Page 3: ...ontainer This number may be obtained from Patton Electronics Technical Service 301 975 1007 http www patton com or support patton com NOTE Packages received without an RMA number will not be accepted...

Page 4: ......

Page 5: ...16 external switches are grouped into two eight switch sets and are externally accessible from the underside of the Model 1075 See Figure 1 The two sets of DIP switches on the underside of the Model 1...

Page 6: ......

Page 7: ...terminal interface Off On Receive Recover System clock derived from the received line signal Switch S2 5 Carrier Control S2 5 Carrier Description Off Always On Transmitter is always ON On Follows ter...

Page 8: ......

Page 9: ...e 6 below The X 21 DCE DTE strap is located near the DB 15 connector on the PC board The arrows on the top of the strap indicate the configuration of the Model 1075 For example if the DCE arrows are p...

Page 10: ......

Page 11: ...pair interface 2 To function properly the Model 1075 needs two twisted pairs of metallic wire These pairs must be unconditioned dry metallic wire between 19 and 26 AWG the higher number gauges may li...

Page 12: ......

Page 13: ...d with the standard version of the Model 1075 is a wall mount type and may be plugged into any approved 120 VAC wall plug 230 VAC Power IEC The 230 VAC adapter supplied with the international version...

Page 14: ......

Page 15: ...nal equipment is operating properly and can be used for a test If a fault is indicated call a technician or replace the unit C Perform a Bit Error Rate BER test on each unit If the BER test equipment...

Page 16: ......

Page 17: ...terfaces CCITT ITU X 21 Data Rates 32 56 and 64 Kbps switch selectable Isolation 1500V RMS via isolation transformers Surge Protection IEC 801 S Level 2 1kV Carrier Control Constantly on or Controlled...

Page 18: ......

Page 19: ...Female Pin Signal Source 1 Shield 2 Transmit a DTE 3 Control a DTE 4 Receive a DCE 5 Indication a DCE 6 System Clock a DCE 7 8 Signal Ground 9 Transmit b DTE 10 Control b DTE 11 Receive b DCE 12 Indic...

Page 20: ......

Page 21: ......

Page 22: ......

Page 23: ......

Page 24: ...from you Please contact us in any of the following ways to tell us how you like this product and how we can meet your product needs today and in the future Web http www patton com Sales E mail sales...

Reviews: