APPENDIX A

PATTON ELECTRONICS MODEL IM2RC/F-128K 

SPECIFICATIONS

Applications:

128kbps G.703  PCM network extension

G.703 Interfaces:

Symmetrically balanced 4-wire, 120 Ohm
RJ-45 jack termination

Line Interface:

Entire module plugs into 1092RC,
1092ARC, 1094ARC, and 1095RC HDSL
Series Patton transmission devices products

Operating Modes:

Supports clear channel mode; co-direction-
al timing, Rx recovered: 128 kbps±500ppm.

Line Encoding:

AMI with bi-polar violations for octet timing.

Timing Modes:

Modem or network timing

G.703 Input 
Signal Sensitivity:

0 to 9 dB loss @ 250 Khz

Transmit Level:

2.0V differential into 100 Ohms, nominal

Load Impedance:

120 Ohms

Jitter Performance:

CTR 14, G.823

Surge Protection:

Complies with IEC 801.5 level 1, 500V

Isolation:

1500V RMS isolation, transformer coupled

PCB Dimensions:

2.04” x 3.24”

Compliance:

CE Mark

Power Consumption:

<180mA @ 10 VAC RMS, including integrat-
ed front card modem with the rack card
power supply under full load

Temp. Range:

0 - 60º C (32 - 140º F)

Altitude Range:

Up to 15,000 ft (4572 m)

Humidity Range:

5 - 95% non-condensing

APPENDIX B

PATTON ELECTRONICS MODEL IM2RC/F-128K

CABLE RECOMMENDATIONS

All Patton Electronics Company Baseband Modems, CSU/DSUs

and Short Range Modem are tested to the distances published in our
Catalogs and Specification Sheets on twisted-pair cable with the follow-
ing characteristics:

Wire Gauge

Capacitance

Loop Resistance

19 AWG

83nF/mi or 15.72 pF/ft.

.0163 ohms/ft.

22 AWG

83nF/mi or 15.72 pF/ft.

.0326 ohms/ft.

24 AWG

83nF/mi or 15.72 pF/ft.

.05165 ohms/ft.

26 AWG

83nF/mi or 15.72 pF/ft.

.08235 ohms/ft.

We fully expect that the Baseband Modems, CSU/DSUs and Short

Range Modems will operate on lines with specifications different from
those tested, but to reduce the potential difficulties in the field, one
should ensure that the cable being used has similar or better charac-
teristics (lower capacitance or lower resistance).

Wire with capacitance of 20pF/ft. or less is suitable for all Baseband

Modems, CSU/DSUs and Short Range Modems. However, distances
may vary from those published in our catalog. Resistance will also
affect distance but not functionality. Wire should be 26 AWG or larger
(smaller AWG#).

Patton products are designed to withstand normal environmental

noise and conditions; however, other environmental factors too numer-
ous to discuss in this format may affect proper operation.

Selection of the proper Baseband Modem, CSU/DSU or SRM for

an application is critical to maintaining Customer Satisfaction and must
be taken seriously. Certain models are better suited for particular
applications and environments than others.

Summary of Contents for IM2RC/F-128K

Page 1: ...EL IM2RC F 128K Co Directional Rack Mount Modem Rear Card SALES OFFICE 301 975 1000 TECHNICAL SUPPORT 301 975 1007 http www patton com Part 07MIM2RC F128 A Doc 078541UA Revised 07 27 99 An ISO 9001 Ce...

Page 2: ...idental or consequen tial damages arising from the use of or inability to use this product Patton Electronics specifically disclaims all other warranties expressed or implied and the installation or u...

Page 3: ...Network Termination Complies with ITU T G 823 Jitter Control Specifications Supports Clear Channel Built in Transformer Isolation and Surge Protection Supports Network or Modem Timing Fits in Patton s...

Page 4: ...e source of the system tim ing The system timing may be provided by 1 The G 703 network or 2 The local function card or remote baseband modem CSU DSU either a rackable function card or stand alone uni...

Page 5: ...e driver board that allows you to configure your front function card for G 703 operation Figure 3 shows the Interface Driver Board connected to a Model 1092ARC front func tion card You may also use th...

Page 6: ...tton function card access products that support 64k 128k synchronous data rates The two cards meet inside the rack chassis and plug into each other by way of mating 50 pin card edge connectors Use the...

Page 7: ...must have the proper 2 Wire 4 Wire setting For instance if you are operating in 2 Wire mode both units must be in the 2 Wire setting Similarly if you are operating in 4 Wire mode both units must be in...

Page 8: ...TRUCTIONS In order to operate the Model IM2RC F 128K must be installed in the rear of a Patton 16 port rack or a 2 4 or 8 port ClusterBox chas sis A front function card such as a baseband modem CSU DS...

Page 9: ...t Range Modem are tested to the distances published in our Catalogs and Specification Sheets on twisted pair cable with the follow ing characteristics Wire Gauge Capacitance Loop Resistance 19 AWG 83n...

Page 10: ...nt Rear Power Supply Entry Module 1000CC Control Card 1000RCM703 64DB Interface daughter card G 703 1180RCDB Interface daughter card V24 V 35 0805US American Power Cord 0805EUR European Power Cord CEE...

Page 11: ...FACE PIN ASSIGNMENT RJ45 Female Connector Pin Number Signal 1 4 Wire RX 2 4 Wire RX 3 no connection 4 2 Wire TIP 4 Wire TX 5 2 Wire RING 4 Wire TX 6 no connection 7 no connection 8 no connection Copyr...