Command Line Interface (CLI)
39
TrinityAE Administrator’s Reference Guide
6 • Sync Serial Configuration
Command Line Interface (CLI)
Example – show controller sync-serial command:
V.35 DTE Serial Device Status
CD: OFF
CTS: OFF
DSR: OFF
DTR: ON
RTS: OFF
Clock Invert: False
Enabled: False
Table 8. Stat Mux- CLI Commands
Step
Explanation
configure controller sync-serial
Enter the sync-serial interface configuration mode.
clock
Set the parameters.
clock invert
Invert the clock signal.
clock rate <4K-7168K>
Set the generated clock sample rate in the range from 4K to
7168K (DCE interface only).
[no] shutdown
Enable or disable the sync-serial interface.
status
Display the status and configuration of the sync-serial interface.
show controller sync-serial
Display the status and configuration of the sync-serial interface.