background image

USER 

 

MANUAL

MODEL 2151

 

CopperLINK™ Variable Rate

 

Ethernet Extender

SALES OFFICE
(301) 975-1000
TECHNICAL SUPPORT
(301) 975-1007

Part# 07M2151-UM

Rev. B

Revised 8/31/10

An ISO-9001Certified

Company

This is a Class A device and is not intended for 
use in a residential environment.

Summary of Contents for COPPERLINK 2151

Page 1: ...ariable Rate Ethernet Extender SALES OFFICE 301 975 1000 TECHNICAL SUPPORT 301 975 1007 Part 07M2151 UM Rev B Revised 8 31 10 An ISO 9001Certified Company This is a Class A device and is not intended for use in a residential environment ...

Page 2: ...10 100Base T Ethernet Interface 11 3 3 Connecting Power 12 4 0 Configuration 12 4 1 Configuring the hardware DIP switches 12 4 2 Configuring DIP Switch S1 14 5 0 Operation 14 5 1 Power Up 14 5 2 Front Panel LED Status Monitors 15 A Specifications 16 A 1 LAN Connection 16 A 2 Transmission Line 16 A 3 CopperLINK Line Rate and CopperLINK Distance 16 A 4 LED Status Indicators 16 A 5 Power Supply 16 A ...

Page 3: ...3 D Distance Chart Based on 24 AWG 0 5 MM 19 ...

Page 4: ...al or consequential damages arising from the use of or inability to use this product Patton Electronics spe cifically disclaims all other warranties expressed or implied and the installation or use of this product shall be deemed an acceptance of these terms by the user Note Conformity documents of all Patton products can be viewed online at www patton com under the appropriate product page 1 1 RE...

Page 5: ...his device is in compliance with the essential requirements and other relevant provisions of Directive 2004 108 EC relating to electromagnetic compatibility and Directive 2006 95 EC relating to electrical equipment designed for use within cer tain voltage limits The Declaration of Conformity may be obtained from Patton Electronics Inc at www patton com certifications The safety advice in the docum...

Page 6: ...le used meets all applicable standards for the country in which it is to be installed For AC powered devices which have 3 conductor power plugs L1 L2 GND or Hot Neutral Safety Protective Ground the wall outlet or socket must have an earth ground For DC powered devices ensure that the interconnect ing cables are rated for proper voltage current antici pated temperature flammability and mechanical s...

Page 7: ...uipment Electrostatic Discharge ESD can damage equipment and impair electrical circuitry It occurs when electronic printed circuit cards are improperly handled and can result in complete or intermittent failures Do the fol lowing to prevent ESD Always follow ESD prevention procedures when removing and replacing cards Wear an ESD preventive wrist strap ensuring that it makes good skin contact Conne...

Page 8: ...nt operation LED indicators for Power Link Ethernet Link Activity and Remote Local 2 2 DESCRIPTION The Patton Electronics Model 2151 CopperLink modems provide high speed LAN connections between peered Ethernet LANs remote PC s or any other network enabled 10 100Base T device Operating in pairs one Model 2151 is configured as the L Local unit located at one end of the LAN extension and the other Mo...

Page 9: ...1 Connecting the Twisted Pair Line Interface on page 10 Note See Figure 2 for the standalone unit s rear panel arrangements 2 Connect the Ethernet interface refer to section 3 2 Connecting the 10 100Base T Ethernet Interface on page 11 3 Connect the power plug refer to section 3 3 Connecting Power on page 12 The Interconnecting cables shall be acceptable for external use and shall be rated for the...

Page 10: ...low the steps below to connect the Model 2151 CopperLINK Inter faces Note The Model 2151 units work in pairs One of the units must be configured as a L Local unit and the other unit must be config ured as a R Remote unit The Interconnecting cables shall be acceptable for external use and shall be rated for the proper applica tion with respect to voltage current anticipated tem perature flammabilit...

Page 11: ...n rela tionship is shown in Figure 3 Figure 3 Model 2151 RJ 45 twisted pair line interface 3 2 CONNECTING THE 10 100BASE T ETHERNET INTERFACE The shielded RJ 45 ports labeled Ethernet are the Auto MDIX10 100Base T interface These ports are designed to connect directly to a 10 100Base T network Figure 4 shows the signal pin rela tionships on this interface You may connect this port to a hub or PC u...

Page 12: ...m Center pin is 5V The barrel type plug has a 2 5 5 5 10mm I D O D Shaft Length dimensions 4 0 CONFIGURATION The Model 2151 has four DIP switches S1 for configuring the unit for a wide variety of applications This section describes switch locations and explains the different configurations 4 1 CONFIGURING THE HARDWARE DIP SWITCHES Using a small flat tip screwdriver remove the protective cover loca...

Page 13: ... 4 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 O...

Page 14: ...ED status monitors 5 1 POWER UP Before applying power to the Model 2151 please review section 3 3 Connecting Power on page 12 to verify that the unit is connected to the appropriate power source Table 1 2151 Firmware Configuration Position S1 1 S1 2 S1 3 S1 4 Master Slave Rate ON Slave CPE 4 1 9 1 16 2 6 6 10 10 15 15 Rate Control See table below OFF Master CO S1 2 S1 3 S1 4 Rate DS US DS Downstre...

Page 15: ... Off The device is powered off CopperLink Green The port is connected Blinking Green Data transceiving Off No valid link on this port Ethernet Green The port is connected Blinking Green Once the unit connects to a power source the Link LED will blink as the 2151 automatically looks for the other unit in the pair Data transceiving Local Green The device acts in Local mode Off Local mode is off Remo...

Page 16: ...nce 5 750 ft 1 7 km at 1 Mbps upstream 4 Mbps downstream Note Distances depend on selected line rate and line conditions See Appendix D on page 19 for details A 4 LED STATUS INDICATORS Power Green CopperLINK Link Green Ethernet Link Green Activity Flashing Green Remote Green Local Green A 5 POWER SUPPLY External AC and DC options AC 120 VAC 220 VAC and UI 120 240 VAC DC 12 VDC 24 VDC and 48 VDC Po...

Page 17: ...thernet Extender Kit 2 units preset to local and remote 110 240VAC 07M2151 UM User Manual Power Supplies 08055DCUI 08055 120 5 1 100 240VAC 5V reg DC 2A Universal Input Adapter 120 VAC 5V reg DC 1A Input Adapter 12V PSM 12 VDC Input Adapter 24V PSM 24 VDC Input Adapter 48V PSM 48 VDC Input Adapter Power Cords 0805US American Power Cord 0805EUR European Power Cord CEE 7 0805UK United Kingdom Power ...

Page 18: ...EL 2151 SERIES INTERFACE PIN ASSIGNMENT C 1 10 100BASE T INTERFACE RJ 45 Pin 1 TX Pin 2 TX Pin 3 RX Pin 6 RX Pins 4 5 7 8 no connection C 2 COPPERLINK INTERFACE RJ 45 Pin 4 RING Pin 5 TIP Pins 1 2 3 6 7 8 no connection ...

Page 19: ...t and type gauge of wire used Note DS downstream US upstream Rate Distance in Feet km Throughput at Max Distance megabits per second 4 1 5 500 1 6 km 4 00 DS 1 00 US 9 1 5 750 1 7 km 8 98 DS 1 0 US 16 2 4 700 1 4 km 15 92 DS 2 0 US 6 6 5 500 1 6 km 5 98 DS 5 98 US 10 10 5 000 1 5 km 9 99 DS 9 99 US 15 15 4 250 1 2 km 14 96 DS 14 96 US ...

Page 20: ...20 Copyright 2010 Patton Electronics Company All Rights Reserved ...