background image

APPENDIX C (continued)

TSB-40A COMPLIANCE TESTING RESULTS

TYPICAL ATTENUATION MEASUREMENT

APPENDIX C

EIA/TIA TSB-40A COMPLIANCE

The Model 570-Rx/580-Rx series surge protectors have been

designed to conform to stringent EIA/TIA TSB-40 standards as required
for all Category-5 connecting hardware.  These standards specify the
capacitance and near end cross-talk (N.E.X.T) to insure proper
operation of ALL connected equipment.  Specific test results are shown
in the tables on the following pages*.

TSB-40A COMPLIANCE TESTING RESULTS

TYPICAL NEAR-END CROSSTALK MEASUREMENT

*Note: All test results are for the Model 570-Rx/580-Rx 

alone, not including

any external patch cables that are connected to the unit.

9

10

SOURCE/VICTIM PAIRS

FREQ.

1-2/3-6

1-2/4-5

1-2/7-8

3-6/4-5

3-6/7-8

4-5/7-8

SPEC

MHz

dB

dB

dB

dB

dB

dB

dB

1

82.0

85.0

85.0

78.0

84.0

82.0

>65

4

74.0

77.0

85.0

68.0

73.0

71.0

>65

8

69.0

71.0

83.0

62.8

67.0

64.0

62

10

67.0

69.0

83.0

61.0

66.0

63.0

60

16

63.0

66.0

79.0

56.0

61.0

59.0

56

20

65.5

64.0

78.0

57.0

66.0

56.0

54

25

62.0

62.0

77.0

53.0

58.0

56.0

52

31.25

56.1

62.0

75.5

52.0

54.6

53.0

50

62.5

46.0

56.0

74.0

44.5

46.0

47.0

44

100

45.0

48.0

57.0         40.5

42.0

49.0

40

Figure C-1. N.E.X.T. measurements for Patton Model 570-Rx

SOURCE/VICTIM PAIRS

FREQ.

1-2/3-6

1-2/4-5

1-2/7-8

3-6/4-5

3-6/7-8

4-5/7-8

SPEC

MHz

dB

dB

dB

dB

dB

dB

dB

1

77.0

85.0

85.0

79.0

83.0

81.0

>65

4

70.0

76.0

85.0

68.0

73.0

70.0

>65

8

67.0

70.0

85.0

62.1

67.0

64.0

62

10

67.0

68.0

85.0

61.0

66.0

62.0

60

16

62.0

65.0

83.0

57.0

61.0

58.0

56

20

69.0

65.0

73.0

58.0

63.0

56.0

54

25

59.0

62.0

72.0

53.2

58.0

55.0

52

31.25

57.0

61.0

81.0

51.0

55.0

53.0

50

62.5

51.5

57.0

68.0

45.0

46.0

48.0

44

100

44.0

45.0

54.0          42.0        

41.4

49.0

40

Figure C-2. N.E.X.T. measurements for Patton Model 580-Rx

Freq.

Pins: 1-2

Pins: 3-6

Pins: 4-5

Pins:7-8

Spec

MHz

dB

dB

dB

dB

dB

1

0.0

0.0

0.0

0.1

0.1

4

0.1

0.1

0.1

0.0

0.1

8

0.0

0.1

0.1

0.1

0.1

10

0.0

0.0

0.1

0.0

0.1

16

0.1

0.1

0.1

0.0

0.2

20

0.1

0.1

0.2

0.0

0.2

25

0.0

0.0

0.1

0.0

0.2

35.25

0.0

0.1

0.2

0.0

0.2

62.5

0.2

0.1

0.3

0.0

0.3

100

0.4

0.3

0.4

0.3

0.4

Figure C-3.  Attenuation measurements for Patton Model 570-Rx

Freq.

Pins: 1-2

Pins: 3-6

Pins: 4-5

Pins:7-8

Spec

MHz

dB

dB

dB

dB

dB

1

0.1

0.0

0.1

0.1

0.1

4

0.1

0.1

0.0

0.1

0.1

8

0.0

0.1

0.0

0.1

0.1

10

0.1

0.1

0.1

0.1

0.1

16

0.1

0.1

0.1

0.1

0.2

20

0.1

0.2

0.0

0.2

0.2

25

0.0

0.1

0.1

0.1

0.2

35.25

0.0

0.1

0.0

0.1

0.2

62.5

0.1

0.2

0.1

0.2

0.3

100

0.4

0.3

0.4

0.3

0.4

Figure C-4.  Attenuation measurements for Patton Model 580-Rx

Summary of Contents for 570-R8

Page 1: ...70 R16 580 R8 580 R16 100Base T CAT 5 Surge Protectors SALES OFFICE 301 975 1000 TECHNICAL SUPPORT 301 975 1007 http www patton com Part 07M570 580RC A Doc 074101UA Revised 2 13 97 C E R T I F I E D An ISO 9001 Certified Company ...

Page 2: ...rther details are needed for this measurement Warning This product will not provide complete protection should your equipment or building be subject to a direct lightning hit 1 0 WARRANTY INFORMATION Patton Electronics warrants all Model 570 580 Rack Mount components to be free from defects and will at our option repair or replace the product should it fail within one year from the first date of s...

Page 3: ...i story structures and as a higher capacity replacement for the Model 570 Rx The Model 580 Rx is also well suited for use in severe lightning areas heavy industrial environments and situations where heavy machinery is in the direct vicinity of sensitive LAN equipment and cabling Figure 3 below shows a typical application for the Model 580 Rx For best results the braided grounding strap s on the ra...

Page 4: ...n Electronics Technical Service at 301 975 1007 http www patton com or support patton com Caution Surge energy may run both directions on the ground strap To provide the best protection it is essential that the supplied ground strap on the Model 570 580 Rx is connected to the rack frame structure and that the rack frame structure is directly connected to earth ground Do not lengthen the ground str...

Page 5: ...al patch cables that are connected to the unit APPENDIX A PATTON MODEL 578R8 588 SPECIFICATIONS Environment Category 5 Interfaces that utilize the RJ 45 connector including RS 422 423 10Base T Token Ring Fast Ethernet 100Base T 100Base T4 and ATM Connectors RJ 45 Female Response Time Clamped to 13V after 0 1µS Characteristic 100 Ohms Impedance NEXT Loss worst pair Better than 40 dB at 100 MHz Surg...

Page 6: ...00 45 0 48 0 57 0 40 5 42 0 49 0 40 Figure C 1 N E X T measurements for Patton Model 570 Rx SOURCE VICTIM PAIRS FREQ 1 2 3 6 1 2 4 5 1 2 7 8 3 6 4 5 3 6 7 8 4 5 7 8 SPEC MHz dB dB dB dB dB dB dB 1 77 0 85 0 85 0 79 0 83 0 81 0 65 4 70 0 76 0 85 0 68 0 73 0 70 0 65 8 67 0 70 0 85 0 62 1 67 0 64 0 62 10 67 0 68 0 85 0 61 0 66 0 62 0 60 16 62 0 65 0 83 0 57 0 61 0 58 0 56 20 69 0 65 0 73 0 58 0 63 0 ...

Page 7: ...0 23 20 33 7 33 0 31 0 31 6 23 25 31 0 30 0 34 0 30 0 14 31 25 28 1 27 0 28 0 27 8 14 62 5 21 0 22 0 22 0 22 0 14 100 17 0 21 0 18 2 17 8 14 Freq Pins 1 2 Pins 3 6 Pins 4 5 Pins 7 8 Spec MHz dB dB dB dB dB 1 28 0 28 0 29 0 30 0 23 4 38 0 38 4 47 0 44 5 23 8 39 0 43 8 41 0 41 2 23 10 38 0 44 0 38 0 38 7 23 16 35 0 38 0 30 0 33 4 23 20 33 0 34 0 31 0 31 0 23 25 31 0 31 0 29 0 28 3 14 31 25 29 0 28 0...

Reviews: