APPENDIX B

INTERNATIONAL ELECTROTECHNICAL COMMISSION (IEC)

COMPLIANCE

Meets IEC standards 801.2, 801.4 and 801.5 (CE Mark)

Effective January 1996 the European Economic Community will

require that all electronic devices be tested and comply with all
applicable International standards relating to the product type and
category of use.  Electromagetic Compatibility Directive 89/336/EEC
specifically addresses communication line surge protection devices,
since conformity to immunity standard EN50082-1:1992 is mandatory.
The EN50082-1:10992 standard incorporates International
Organization for Standardization (ISO) publications 801.2 and 801.4,
which describe Electrostatic Discharge and Electrical Fast Transient
requirements.  ISO 801.5 describes Surge Immunity Requirements and
is expected to be adopted as a mandatory requirement under
EN50082-1 by the Technical Committee. in 1996.  Any protector sold
into the international community must meet these standards.  This
device has been tested* and found to comply with these standards as
evidenced by its CE mark.

*Note:

All test results are for the Model 570-Rx/580-Rx 

alone, not including 

any external patch cables that are connected to the unit.

APPENDIX A

PATTON MODEL 578R8/588 SPECIFICATIONS

Environment: 

Category-5 Interfaces that utilize the RJ-45 
connector, including RS-422, 423, 10Base-
T, Token  Ring, Fast Ethernet, 100Base-T, 
100Base-T4 and ATM

Connectors:  

RJ-45 Female 

Response Time:  

Clamped to 13V after 0.1µS

Characteristic 

100 Ohms

Impedance:
NEXT Loss

(worst pair): 

Better than -40 dB at 100 MHz

Surge Clamping

Model 570-Rx: 13 V max with 1 KV 

Voltages

Input;  Model  580-Rx: 15 V max with 2 KV 
Input

Surge Rating:  

IEC 801.5 Standard Level

DC Clamping 

Voltages:  

Common Mode to Gnd,  7.5 V (each line) 
@ 50 mA; Differential mode,  8.1 V (per 
pair) @ 50 mA 

Insertion Loss:  

Less than 0.4 dB (including connector) at all 
frequencies

Return Loss:  

Better than 14 dB on both models

Group Delay:

None, 1 MHz to 100 MHZ

Series Resistance:

Less than 400 milliohms

Grounding: 

External ground strap provides separate 
unit-ground to chassis-ground contact

PC Board 
Dimensions:  

7.0” x 3.0”

Actual Panel 
Dimensions: 

3.47” x 19.0” x 1.1”

Standard
Temperatures

0 - 50

0

C/32 - 122

0

F

Flame Retardance

Plastic cases meet UL 94-V0 standard

7

8

Class

1

1.0 kV

24 A

2

1.0 kV

24 A

3

2.0 kV

48 A

4

(n/a)
(n/a)

5

4.0 Kv

95 A

Wave 

(1.2 x 50 µs)

Forms

(1.2 x 50 µs)

IEC 801-5 Threat Levels as a Function of Class

Sym. Lines Coupling Mode

Line-GND, Zs=42 Ohms

Figure B-1. IEC Threat Levels as a Function of Class. 

Summary of Contents for 570-R8

Page 1: ...70 R16 580 R8 580 R16 100Base T CAT 5 Surge Protectors SALES OFFICE 301 975 1000 TECHNICAL SUPPORT 301 975 1007 http www patton com Part 07M570 580RC A Doc 074101UA Revised 2 13 97 C E R T I F I E D An ISO 9001 Certified Company ...

Page 2: ...rther details are needed for this measurement Warning This product will not provide complete protection should your equipment or building be subject to a direct lightning hit 1 0 WARRANTY INFORMATION Patton Electronics warrants all Model 570 580 Rack Mount components to be free from defects and will at our option repair or replace the product should it fail within one year from the first date of s...

Page 3: ...i story structures and as a higher capacity replacement for the Model 570 Rx The Model 580 Rx is also well suited for use in severe lightning areas heavy industrial environments and situations where heavy machinery is in the direct vicinity of sensitive LAN equipment and cabling Figure 3 below shows a typical application for the Model 580 Rx For best results the braided grounding strap s on the ra...

Page 4: ...n Electronics Technical Service at 301 975 1007 http www patton com or support patton com Caution Surge energy may run both directions on the ground strap To provide the best protection it is essential that the supplied ground strap on the Model 570 580 Rx is connected to the rack frame structure and that the rack frame structure is directly connected to earth ground Do not lengthen the ground str...

Page 5: ...al patch cables that are connected to the unit APPENDIX A PATTON MODEL 578R8 588 SPECIFICATIONS Environment Category 5 Interfaces that utilize the RJ 45 connector including RS 422 423 10Base T Token Ring Fast Ethernet 100Base T 100Base T4 and ATM Connectors RJ 45 Female Response Time Clamped to 13V after 0 1µS Characteristic 100 Ohms Impedance NEXT Loss worst pair Better than 40 dB at 100 MHz Surg...

Page 6: ...00 45 0 48 0 57 0 40 5 42 0 49 0 40 Figure C 1 N E X T measurements for Patton Model 570 Rx SOURCE VICTIM PAIRS FREQ 1 2 3 6 1 2 4 5 1 2 7 8 3 6 4 5 3 6 7 8 4 5 7 8 SPEC MHz dB dB dB dB dB dB dB 1 77 0 85 0 85 0 79 0 83 0 81 0 65 4 70 0 76 0 85 0 68 0 73 0 70 0 65 8 67 0 70 0 85 0 62 1 67 0 64 0 62 10 67 0 68 0 85 0 61 0 66 0 62 0 60 16 62 0 65 0 83 0 57 0 61 0 58 0 56 20 69 0 65 0 73 0 58 0 63 0 ...

Page 7: ...0 23 20 33 7 33 0 31 0 31 6 23 25 31 0 30 0 34 0 30 0 14 31 25 28 1 27 0 28 0 27 8 14 62 5 21 0 22 0 22 0 22 0 14 100 17 0 21 0 18 2 17 8 14 Freq Pins 1 2 Pins 3 6 Pins 4 5 Pins 7 8 Spec MHz dB dB dB dB dB 1 28 0 28 0 29 0 30 0 23 4 38 0 38 4 47 0 44 5 23 8 39 0 43 8 41 0 41 2 23 10 38 0 44 0 38 0 38 7 23 16 35 0 38 0 30 0 33 4 23 20 33 0 34 0 31 0 31 0 23 25 31 0 31 0 29 0 28 3 14 31 25 29 0 28 0...

Reviews: