Jumper JP3:  75 Ohm RX Shield to 120 Ohm Overall Shield

In the default “Connected” setting, the 75 Ohm receive in coaxial

shield connects to RJ-45 pin 6, the receive pair shield.

JP3

Setting

Description

Position 1 & 2

Connected

75 Ohm RX shield 
connected to the RJ-45 
overall foil shield 

Position 2 & 3

Not Connected

75 Ohm RX shield not 
connected to the RJ-45 
overall foil shield 

Jumper JP4:  75 Ohm RX Shield to 120 Ohm Rx Pair Shield (Pin 6)

In the default “Connected” setting, the 75 Ohm coaxial shield

connects to the RJ-45 overall foil shield.

JP4

Setting

Description

Position 1 & 2

Not Connected

75 Ohm RX shield not 
connected to the RJ-45 
RX pair shield (Pin 6)

Position 2 & 3

Connected

75 Ohm RX shield 
connected to the RJ-45 
RX pair shield (Pin 6)

Jumper JP7:  RJ-45 Shield to Chassis Ground

In the default “Connected” setting, the RJ-45 overall shield

connects to chassis ground.

JP7

Setting

Description

Position 1 & 2

Connected

RJ-45 shield connects 
to Frame Ground.

Position 2 & 3

Not Connected

RJ-45 shield does not 
connect to Frame 
Ground.

5

6

4.0  INSTALLATION

This section describes the functions of the Model 460RC16 rack

chassis, tells how to install front and rear Model 460RC/F Series cards
into the chassis, and how to connect to the twisted pair interface and
the serial interface.

4.1  THE MODEL 460R16 RACK CHASSIS

The Model 460R16 Rack Chassis (Figure 3, below) can

accomodate up to 16 G.703 75 Ohm coax to 120 Ohm RJ-45 baluns.
Measuring only 3.5” high, the Model 460R16 is designed to occupy only
2U in a 19” rack.  Sturdy front handles allow the Model 460R16 to be
extracted and transported conveniently.

4.2  INSTALLING THE MODEL 460RC/F MODULE INTO THE

CHASSIS

The Model 460RC16 comprised of a 2U high rack chassis and

individually mountable G.703 balun modules.  You may purchase a fully
populated 16 port rack or you may purchase individual modules.  Refer
to Figure 4 as a guide and follow the steps below to install each Model
additional 460RC/F module into the rack chassis:

1.

Slide the two star washers over the screws on each end of the
mount space.

2.   Slide the Model 460RC/F pc board over the screws with the

BNC connectors facing downward.  Then push the BNC
connectors and RJ-45 connector through the matching slots in
the front of the rack assembly.

3.

Slide a plastic spacer over each screw to secure the pc board. 

Figure 3.  Fully Populated Model 460RC16 Rack Chassis

Summary of Contents for 460RC

Page 1: ...L 460RC Rack Mounted G 703 Coax to Twisted Pair Adapters BALUNs SALES OFFICE 301 975 1000 TECHNICAL SUPPORT 301 975 1007 http www patton com Part 07M460RC A Doc 019081UA Revised 3 13 98 An ISO 9001 Ce...

Page 2: ...975 1007 http www patton com or support patton com NOTE Packages received without an RMA number will not be accepted Patton Electronics technical staff is also available to answer any questions that...

Page 3: ...d to the RJ 45 overall foil shield 4 3 0 CONFIGURATION Each Model 460RC F Module is equipped with four jumpers that you may use to configure several grounding options This section shows the jumper loc...

Page 4: ...s of the Model 460RC16 rack chassis tells how to install front and rear Model 460RC F Series cards into the chassis and how to connect to the twisted pair interface and the serial interface 4 1 THE MO...

Page 5: ...0 feet 200m 4 4 CONNECTING THE 120 OHM RJ 45 PORTS The pin configuration of the 120 Ohm twisted pair port is shown below RJ 45 Pin s Function 1 TX Output 2 TX Output 3 TX Shield 4 RX Input 5 RX Input...

Page 6: ...one required Link to Data Isolation 500 volts AC DC Temperature Range 32 122 F 0 50 C Dimensions w o handles 19 Wide x 3 5 High x 1 9 Deep 48 3 x 8 9 x 4 8 cm APPENDIX B PATTON ELECTRONICS MODEL 460RC...

Page 7: ...ny All Rights Reserved APPENDIX C PATTON ELECTRONICS MODEL 460RC F PIN ASSIGNMENTS 120 OHM TWISTED PAIR INTERFACE RJ 45 Jack Pin No Signal 1 Transmit Data Out 2 Transmit Data Out 3 Transmit Data Shiel...

Reviews: