3.1.1  Jumper Straps JP1, JP2, JP3, JP4, and JP7

The jumper straps allow you to set shielding and grounding options

for the Model 460RC/F.  The settings for each jumper strap are shown
briefly in the table below.  Following this table are more detailed
explanations of each jumper.

Jumper JP1:  75 Ohm TX Shield to 120 Ohm TX Pair Shield (Pin 3)

In the default “Connected” setting, the 75 Ohm transmit out coaxial

shield connects to RJ-45 pin 3, the transmit pair shield.

JP1

Setting

Description

Position 1 & 2

Not Connected

75 Ohm TX shield not 
connected to RJ-45 TX 
pair shield (Pin 3).

Position 2 & 3

Connected

75 Ohm TX shield 
connected to RJ-45 TX 
pair shield (Pin 3). 

Jumper JP2:  75 Ohm Shield to 120 Ohm Overall Shield

In the default “Connected” setting, the 75 Ohm transmit out coaxial

shield connects to the RJ-45 overall foil shield.

JP2

Setting

Description

Position 1 & 2

Connected

75 Ohm TX shield 
connected to the RJ-45 
overall foil shield.

Position 2 & 3

Not Connected

75 Ohm TX shield not 
connected to the RJ-45 
overall foil shield.

4

3.0  CONFIGURATION

Each Model 460RC/F Module is equipped with four jumpers that

you may use to configure several grounding options.  This section
shows the jumper locations and describes their functions.

3.1  SETTING THE JUMPER STRAPS 

There are five configuration jumpers on the back side of the Model

460RC/F printed circuit board.  These jumpers are labeled below and
on the PC board as “JP1”, “JP2”, “JP3”, “JP4”, and “JP7”.  Figure 1,
below, shows their positions on the pc board as well as the relative pin
numbers on the jumpers.  

Figure 2 (below) shows the orientation of the rear interface card

straps.  Observe that the strap can either be on posts 1 and 2, or on
posts 2 and 3. 

3

Figure 1.  Individual Model 460RC/F Card

1
2
3

1
2
3

1
2
3

1
2
3

1
2
3

JP3

JP4

JP7

JP2

JP1

Figure 2.  Possible Positions for Model 460RC/F Jumpers

INTERFACE CARD STRAP SUMMARY TABLE #1

Strap

Function

Position 1&2

Position 2&3

JP1

Coax TX Shield & RJ45 Pin 3

Open*       

Connected

JP2

Coax TX Shield & RJ-45 Shield

Connected*

Open

JP3

Coax RX Shield & RJ-45 Shield

Connected*       

Open

JP4

Coax RX Shield & RJ-45 Pin 6

Open*

Connected

JP7

RJ-45 Shield & Chassis Ground

Connected*

Open

* Indicates default setting

Summary of Contents for 460RC

Page 1: ...L 460RC Rack Mounted G 703 Coax to Twisted Pair Adapters BALUNs SALES OFFICE 301 975 1000 TECHNICAL SUPPORT 301 975 1007 http www patton com Part 07M460RC A Doc 019081UA Revised 3 13 98 An ISO 9001 Ce...

Page 2: ...975 1007 http www patton com or support patton com NOTE Packages received without an RMA number will not be accepted Patton Electronics technical staff is also available to answer any questions that...

Page 3: ...d to the RJ 45 overall foil shield 4 3 0 CONFIGURATION Each Model 460RC F Module is equipped with four jumpers that you may use to configure several grounding options This section shows the jumper loc...

Page 4: ...s of the Model 460RC16 rack chassis tells how to install front and rear Model 460RC F Series cards into the chassis and how to connect to the twisted pair interface and the serial interface 4 1 THE MO...

Page 5: ...0 feet 200m 4 4 CONNECTING THE 120 OHM RJ 45 PORTS The pin configuration of the 120 Ohm twisted pair port is shown below RJ 45 Pin s Function 1 TX Output 2 TX Output 3 TX Shield 4 RX Input 5 RX Input...

Page 6: ...one required Link to Data Isolation 500 volts AC DC Temperature Range 32 122 F 0 50 C Dimensions w o handles 19 Wide x 3 5 High x 1 9 Deep 48 3 x 8 9 x 4 8 cm APPENDIX B PATTON ELECTRONICS MODEL 460RC...

Page 7: ...ny All Rights Reserved APPENDIX C PATTON ELECTRONICS MODEL 460RC F PIN ASSIGNMENTS 120 OHM TWISTED PAIR INTERFACE RJ 45 Jack Pin No Signal 1 Transmit Data Out 2 Transmit Data Out 3 Transmit Data Shiel...

Reviews: