1.3  EQUIPMENT ATTACHMENT LIMITATIONS
Notice: 
The Industry Canada label identifies certified equipment. This
certification means that the equipment meets telecommunications net-
work protective, operational and safety requirements as prescribed in
the appropriate Terminal Equipment Technical Requirements docu-
ment(s). The Department does not guarantee the equipment will oper-
ate to your satisfaction. Before installing this equipment, ensure that it
is permissible to be connected to the facilities of the local telecommuni-
cations company. The equipment must also be installed using an
acceptable method of connection. Be aware that compliance with the
above conditions may not prevent degradation of service in some situ-
ations. Repairs to certified equipment should be coordinated by a rep-
resentative designated by the supplier. Any repairs or alterations you
make to this equipment, or equipment malfunctions, may give the
telecommunications company cause to request the user to disconnect
the equipment. Ensure for your own protection that the electrical
ground connections of the power utility, telephone lines and internal
metallic water pipe system, if present, are connected together. This
precaution may be particularly important in rural areas. 

CAUTION: Do not attempt to make such connections yourself.
Instead, contact the appropriate electric inspection authority, or
electrician, for assistance. 

Notice: The Ringer Equivalence Number (REN) assigned to each ter-
minal device provides an indication of the maximum number of termi-
nals allowed to be connected to a telephone interface. The termination
on an interface may consist of any combination of devices subject only
to the requirements that the sum of the Ringer Equivalence Numbers
of all the devices does not exceed five.

1.4 PATTON CONTACT INFORMATION

If you have any trouble operating the Model 2710RC, contact

Patton Electronics Technical Support at 301-975-1000. The tele-
phone company may ask you to disconnect the equipment from the
telephone network until the problem has been corrected or until you
are certain that the Model 2710RC is not malfunctioning. In accor-
dance with FCC rules and regulation CFR 47 68.218(b)(6), you must
notify the telephone company prior to disconnection. 

The following information may be required when applying to your

local telephone company for leased line facilities. The Universal
Service Order Code (USOC) is RJ-48C. The Facility Interface Codes

(FIC) are 04DU9-BN, 04DU9-DN, 04DU9-1KN, and 04DU9-1SN. The
Service Order Code (SOC) is 6.0N.

Facility

Service

Network

Service

Interface

Code

Connection

Code

1.544 Mbps SF format 
without line power

04DU9-BN

6.0N

RJ48C

1.544 Mbps SF and 
B8ZS without line power

04DU9-DN

6.0N

RJ48C

1.544 Mbps ANSI ESF 
without line power

04DU9-1KN

6.0N

RJ48C

1.544 Mbps ANSI ESF and 
B8ZS without line power

04DU9-1SN

6.0N

RJ48C

FCC PART 68 COMPLIANCE STATEMENT

This equipment complies with Part 68 of FCC Rules. Please note

the following:

1.

You are required to request service from the telephone company

before you connect the CSU to a network. When you request serv-
ice, you must provide the telephone company with the following data.
When you request T1 Service, you must provide the telephone com-
pany with the Facility Interface Code. Provide the telephone compa-
ny with both of the following codes: 04DU9-B (1.544 MB D4 framing
format) and 04DU9-C (1.544 MB ESF format). The telephone com-
pany will select the code it has available. The Service Order Code(s)
(SOC): 6.0N. The required Universal Service Order Code (USOC)
jack: RJ 48C. The make, model number, and FCC Registration num-
ber of the CSU.

2.

Your telephone company may make changes to its facilities, equip-

ment, operations, or procedures that could affect the proper func-
tioning of your equipment. The telephone company will notify you
in advance of such changes to give you and opportunity to main-
tain uninterrupted telephone service.

3.

If your CSU causes harm to the telephone network, the telephone

company may temporarily discontinue your service. If possible,
they will notify you in advance, but if advance notice is not practi-
cal, you will be notified as soon as possible and will be informed of
your right to file a complaint with the FCC.

4.

If you experience trouble with the CSU, please contact Patton

Electronics, Co. for service or repairs. Repairs should be per-
formed only by Patton Electronics Co.

5.

You are required to notify the telephone company when you dis-

connect the CSU from the network.

3

Summary of Contents for 2710RC Series

Page 1: ...______________________________________ __________________________________________ __________________________________________ __________________________________________ ________________________________...

Page 2: ...product fails or does not perform as warranted your sole recourse shall be repair or replacement as described above Under no condition shall Patton Electronics be liable for any damages incurred by t...

Page 3: ...ance with FCC rules and regulation CFR 47 68 218 b 6 you must notify the telephone company prior to disconnection The following information may be required when applying to your local telephone compan...

Page 4: ...rols The Netlink T1 supports D4 ESF framing options and AMI B8ZS B7ZS line coding Netlink T1 also supports a full range of system and diagnostic features that make system setup easy The NetLink T1 pro...

Page 5: ...aming bits are now used for framing CRC and the Facility Data Link FDL The FDL allows maintenance messages and information to be passed between the 2710RC and the Central Office Line Coding Options Al...

Page 6: ...with your DTE equip ment for more information on its operation In most cases when there are errors on the line only in the direction of the transmit data either S2 2 or S2 3 can be changed to solve t...

Page 7: ...CM12548C Strap Settings Figure 5 shows strap locations for the Model 1001RCM12548C DB 25 rear cards These straps determine various grounding charac teristics for the terminal interface and twisted pai...

Page 8: ...onnected position this strap links M 34 pin A frame ground In the open position pin A is disconnected from frame ground JB3 Position 1 2 DTE Shield Pin A and FRGND Connected Position 2 3 DTE Shield Pi...

Page 9: ...is described below For more information on the Model 1001CC please refer to the Model 1001CC user manual 3 3 1 Setting the Card Address The 2710RC contains two rotary switches S3 and S4 which are use...

Page 10: ...ter Carriage Return key The password prompt will be displayed as shown below 6 Note The password is case sensitive Type the password and press Enter The factory default password for the unit is patton...

Page 11: ...to permanent memory Logoff For security log off the control menu by executing the Logoff command This will blank the screen until an Enter key is pressed 3 3 4 System Configuration The default System...

Page 12: ...sity This is the most acceptable way to accomplish 64 kb s on each DS0 channel B7ZS This stands for Bipolar Seven Zero Substitution Instead of introducing bipolar violations this method substitutes a...

Page 13: ...default Options Enabled Disabled The ESF format provides the CO the ability to put the customer installation s NetLink T1 into loopback mode The NetLink T1 rec ognizes these special messages that are...

Page 14: ...S0 Channel Rate is 56kbps the Bandwidth Selected will be a multiple of 56k not of 64k When using the DIP switches to set the band width the starting channel is always channel 1 Front Panel Switches En...

Page 15: ...e returning to the Idle state TxP The NetLink T1 is sending a test pattern while in Test Mode TxUp The NetLink T1 is sending the Loop Up command to initi ate a CSU loopback TxDN The NetLink T1 is send...

Page 16: ...ng error exceeds a certain threshold of errors This may happen due to a disconnected line an extremely noisy connection or mismatched framing Loss of Sync LOS occurs when the T1 framer in the unit can...

Page 17: ...1 and 2 are provided for easy identification of your unit after installation You may want to give each unit a unique name via the header lines to help distinguish one unit from another You can enter a...

Page 18: ...factory default configuration except for the header lines and the password by executing the Set to Default Configuration command Service Information If you need to contact us for help you can view the...

Page 19: ...ual AC and DC Rack Mount Power Supplies for fuse and power card replacement information 4 2 INSTALLING THE INTERFACE DRIVER BOARD The DTE electrical interface on the 2710RC is determined by a DTE daug...

Page 20: ...r host computer When making the connection to your DTE device use a straight through cable of the shortest possible length we recommend 6 feet or less When purchasing or constructing an interface cabl...

Page 21: ...os controlled slips severe errors or bit errors when sending V 52 test patterns When sending a test pattern the LED will remain lit if the unit does not receive the identical pattern When it receives...

Page 22: ...L test follow these steps 1 Activate RDL This may be done in three ways a Enter Remote Loop from the System 42 Diagnostics Statistics menu and toggle the Spacebar until RL appears next to the Remote L...

Page 23: ...AT E Test Pattern with Error Injection 44 APPENDIX A PATTON NETLINK T1 MODEL 2710RC SPECIFICATIONS WAN Speed 1 544 Mbps WAN Connection RJ 48C Nominal Impedance 100 Ohms DTE Interface EIA 530 ITU T V 3...

Page 24: ...35 Interface with M 34F RJ48C Rear Card 1001RPEM RAC 120 240V Rear Power Entry Module 1001RPEM RAC 120 240V Rear Power Entry Module 1001RPSM RUI 120 240V Front Power Supply Module 1001RPEM RDC DC Rea...

Page 25: ...nd Shield B SGND Signal Ground D CTS DCE Source E DSR DCE Source Always On F CD DCE Source L LL Local Loop DTE Source M TM Test Mode Indicator DCE Source N RL Remote Loop DTE Source P TD Transmit Data...

Page 26: ...A DTE Source 15 TC Transmitter Clock B DCE Source 16 RD Receive Data A DCE Source 17 RC Receiver Clock A DCE Source 18 LL Local LIne Loop 19 RTS Request to Send B DTE Source 20 DTR Data Terminal Ready...