SWITCH S2-2:  CRC-4 MULTIFRAME

In framed mode, S2-2 is used for CRC-4 MF. When CRC-4 is enabled,
the unit monitors the incoming data stream for CRC-4 errors. It trans-
mits CRC-4 error counts to the transmitting unit.. When using timeslot
zero (TS0), excessive errors may cause loss of frame or loss of sync.
If CRC-4 MF is used, both units must be set for set for CRC-4 MF.
Otherwise, the one using CRC-4 MF will detect loss of sync.

S2-2

Option

Off

CRC-4 Disabled

On

CRC-4 Enabled

NOTE: When the data rate is set to 2.048Mb/s, then the unit is
forced into G.703 mode, and it transmits user data on all 32 time-
lots. There is no framing information; therefore, the CRC4 MF (S2-
2) switch is ignored. In all other rate settings, the unit employs
G.704 framing; TS0 is reserved for signaling. 

SWITCH S2-3: REMOTE DIGITAL LOOPBACK TYPE

The user can set this switch to select the type of remote loop that

will be initiated by the Model 2701.  If set to V.54, the Model 2701 will
initiate a V.54 loop when Remote Loop is selected by the front panel
switches.  If set to CSU, the Model 2701 will initiate a CSU loop when
Remote Loop is selected by the front panel switches.  

S2-3

RDL Type

Off

Initiate a V.54 RDL loop when selected

On

Initiate a CSU loopback when selected

SWITCH S2-4:  RDL RESPONSE 

V.54 and CSU Loopbacks are special in-band loopback facility that

sends a pseudo-random pattern over the data stream. This is useful for
campus applications when you need to put a remote unit in loopback.
The unit responds to the V.54 loopback command, and the whole
process takes only a few seconds to complete.  When V.54 Loopback
is disabled, the unit will not be able to send or respond to V.54 or CSU
loopback commands. The duration of the loopback is limited by the
loopback timeout setting.

S2-4

Option

Off

RDL Response Disabled

On

RDL Response 

Enabled

SWITCH S2-5 TEST MODE REQUEST FROM DTE

Use Switch S2-5 to allow Model 2701RC to enter loopback tests when
the DTE raises the appropriate loop request pin.

S1-8

Setting

Off

Response to DTE Loopback Request Enabled

On

Response to DTE Loopback Request Disabled

SWITCH S2-6 FRONT PANEL SWITCHES

As the Front Panel Switches may be inadvertently toggled, or in the
event that the end-user may not need to use the switches, the installer
may disable the front panel switches.  Set Switch S2-6 to determine
whether the front-panel toggle switches are enabled or disabled.

S2-6

Option

On

Front Panel Switches Enabled

Off

Front Panel Switches Disabled

SWITCH S2-7 VT-100 OR NMS SELECTION 

Switch S2-7 selects the configuration mode that the G.703 Access
Rack Card uses. When VT-100 is selected, configuration and status
can be setup through a VT-100 terminal using a 1001CC. When NMS
(network management station) is selected, configuration and status
can be setup and maintained through SNMP using a 1001MC. Please
refer to the 1001MC user manual when using this mode.

Note: Dip switch configuration can be used regardless of the setting of
this switch. The dip switches are enabled through the VT-100 screens,
NMS, or by performing a hardware reset.

S2-7

Management Selection

On

NMS control

Off

VT-100 control

SWITCH S2-8 IMPEDANCE
Switch S2-8 is used to select the line build out for the Model  2701RC.
When using the 1001RCM11575 (dual BNC) rear card, set S2-8 to
OFF. When using a 120 Ohm cable with RJ-45 connectors, set S2-8 to
ON.

S2-8

Setting

75 Ohm

OFF

120 Ohm

ON

Summary of Contents for 2701RC

Page 1: ...tLink E1 E1 Fractional E1 CSU DSU Rack Card SALES OFFICE 301 975 1000 TECHNICAL SUPPORT 301 975 1007 http www patton com Part 07M2701RC B Doc 086131UB Revised 03 09 01 C E R T I F I E D C E R T I F I...

Page 2: ...ot cover customer damage abuse or unauthorized modification This product contains no serviceable parts therefore the user shall not attempt to modify the unit in any way If this product fails or does...

Page 3: ...ES Terminates E1 FE1 Circuits over a 4 Wire RJ 48C interface Connects to standard CPE Serial Interfaces Common Framed nx64 rates up to1984 kbps G 704 Unstructured Rate of 2 048 Mbps G 703 G 703 or G 7...

Page 4: ...change the switch settings to the desired settings When you turn the unit on again the unit will be set up with the selected switch settings Switch S1 1 through S1 8 A detailed description of each sw...

Page 5: ...s the unit is forced into G 703 mode and it transmits user data on all 32 time lots There is no framing information therefore the CRC4 MF S2 2 switch is ignored In all other rate settings the unit em...

Page 6: ...V 54 Loopback is disabled the unit will not be able to send or respond to V 54 or CSU loopback commands The duration of the loopback is limited by the loopback timeout setting S2 4 Option Off RDL Resp...

Page 7: ...strap can either be on pegs 1 and 2 or on pegs 2 and 3 Sections 3 2 1 3 2 2 and 3 2 3 describe the strap locations and possi ble settings for each rear card 3 2 1 Model 1001RCM12548C Strap Settings F...

Page 8: ...igure 6 shows the strap location for the Model 1001RCM13448C M 34 rear card This strap determines whether Signal Ground and Frame Ground will be connected The table below provides an overview of inter...

Page 9: ...ap links Signal Ground and frame ground through a 100 ohm resistor In the open position signal ground is disconnected from frame ground JB4 Position 1 2 SGND and FRGND Connected Position 2 3 SGND and...

Page 10: ...no parity Local echo off ANSI or VT 100 emulation 4 Here is an example of a terminal emulator setup session In normal font are the various parameter types In bold type are the values that should be us...

Page 11: ...inal can generate is 16 characters 7 The NetLink E1 will then display the Main Menu screen 3 3 3 Introduction to Main Menu After entering the password you may access all of the system s functions and...

Page 12: ...s a Service Information screen in case you need technical assistance from Patton Save Changes Once you have configured the unit to your satisfaction you can save the changes permanently by exe cuting...

Page 13: ...en connect ing to a carrier s network In this mode the unit recovers the clock from the received signal and uses it to transmit data In this way the unit remains synchronized to a master clock In camp...

Page 14: ...pback timeout setting While V 54 is being activated user data is overwritten Default Config Source Switch default Options EEPROM Switch The Model 2701RC can be initialized via the configuration in the...

Page 15: ...nd ing a pattern Local loopback is disabled LocP The Model 2701RC is in Local Loopback mode and is sending a test pattern Remote Loop Idle default The Remote Digital Loopback RDL test checks the perfo...

Page 16: ...when Remote Loop is selected by the front panel switches S2 3 RDL Type Off Initiate a V 54 RDL loop when selected On Initiate a CSU loopback when selected Test Pattern Idle default Options Idle or Se...

Page 17: ...s 00 15 fifteen minutes 00 30 thirty minutes default setting 00 45 forty five minutes 01 00 one hour 01 30 90 minutes 02 00 two hours 03 00 three hours NEVER forever the unit will remain in loopback w...

Page 18: ...n a 19 rack Sturdy front handles allow the Model 1001R14 to be extracted and transported conveniently 4 1 1 The Rack Power Supply The power supply included in the Model 1001R14 rack uses the same mid...

Page 19: ...ting toward the front panel of the Model 2701RC pc board 5 Push the Interface Driver Board gently onto the socket and re install into the 1001 rack 4 3 INSTALLING THE MODEL 2701RC INTO THE CHASSIS The...

Page 20: ...d is equipped with dual female BNCs TX and RX for connection to a 75 ohm dual coax G 703 network interface 5 0 OPERATION Once the NetLink E1 is installed and configured properly it is ready to place i...

Page 21: ...urns off when the unit is not powered 5 2 LOOP V 54 TELCO DIAGNOSTICS The NetLink E1 offers three V 54 loop diagnostics and is com patible with two Telco loop diagnostics Use these diagnostics to test...

Page 22: ...to Appendix D c Set the front panel switch to Remote 2 Perform a bit error rate test BERT using the internal V 52 generator as described in Section 5 3 or using a separate BER Tester If the BER test i...

Page 23: ...ohm available when using Patton Model 1001RCM11575 rear card DTE Interface V 35 DCE Orientation X 21 DCE or DTE orientation RS 530 RS 232 10Base T Ethernet Line Coding Selectable AMI or HDB3 Line Fram...

Page 24: ...35 Interface with M 34F RJ48C Rear Card 1001RPEM RAC 120 240V Rear Power Entry Module 1001RPEM RAC 120 240V Rear Power Entry Module 1001RPSM RUI 120 240V Front Power Supply Module 1001RPEM RDC DC Rea...

Page 25: ...Ground Shield B SGND Signal Ground D CTS DCE Source E DSR DCE Source Always On F CD DCE Source L LL Local Loop DTE Source M TM Test Mode Indicator DCE Source N RL Remote Loop DTE Source P TD Transmit...

Page 26: ...a A DTE Source 15 TC Transmitter Clock B DCE Source 16 RD Receive Data A DCE Source 17 RC Receiver Clock A DCE Source 18 LL Local LIne Loop 19 RTS Request to Send B DTE Source 20 DTR Data Terminal Rea...

Reviews: