A.10  COMPLIANCE

 

• Safety & EMC: Patton Internal Safety & EMC Testing, FCC Part 15 

Class A

• Telecom—CE Mark per EMC directive 89/336/EEC and Low Voltage 

Directive 73/23/EEC

 

A.11  POWER

 

• External 120 VAC, 60 Hz AC Power Supply (5 VDC output)

• External 220 VAC, 50 Hz AC Power Supply (5 VDC output)

• External UI AC Power Supply (100–240 VAC, 50–60Hz input, 5 VDC 

output)

• -45 VDC

• -24 VDC

• -12 VDC

 

A.12  PACKAGED WEIGHT

 

Less than 1 lb. (0.45 kg) with power supply

 

A.13  DIMENSIONS

 

3.0L x 1.8W x 0.8H in. (7.6L x 4.4W x 1.9H cm)

 

A.14  ENVIRONMENT

 

Model 2300M and 2312M

• Temperature: 32–95°F (0–35°C)

• Humidity: up to 90% non-condensing

Model 2310M and 2311M

• Temperature: 32–113°F (0–45°C)

• Humidity: up to 90% non-condensing

Copyright © 2002, 2003

Patton Electronics Company

All Rights Reserved.

Summary of Contents for 2300M

Page 1: ...USER MANUAL MODEL 2300M SERIES OpticLink Ethernet Media Converters 2300M 2310M 2311M 2312M Part 07M2300M Doc 077321U Rev A Revised 4 14 03 An ISO 9001 Certified Company...

Page 2: ...1 LED indicators 12 A Specifications 14 A 1 Interfaces Connectors 14 A 2 Interface Speed 14 A 3 Transmission Mode 14 A 4 Twisted Pair Copper Cable Type 14 A 5 Fiber Cable Type 14 1 6 Fiber Wavelength...

Page 3: ...Series generates and uses radio frequency energy and if not installed and used properly that is in strict accordance with the manufacturer s instructions may cause interference to radio and televisio...

Page 4: ...sured to Patton Electronics All returns must have a Return Materi als Authorization number on the outside of the shipping container This number may be obtained from Patton Electronics Technical Servic...

Page 5: ...10Base FL 100Base FX and 100Base SX Supports 802 3 and 802 3u 10Base T 10Base FL 100Base TX 100Base FX and 100Base SX industry standards Extends network connections up to 2 km 1 24 miles 300 m for Mo...

Page 6: ...de and 0 19 miles 0 3 km in 100Base SX mode Note The Model 2311M can be used to connect auto sensing 10 100 10Base T 10Base FL and 100Base T 100Base SX network devices however it is not capable of con...

Page 7: ...network device is on one side of the Model 2312M there must be another 10Base or an auto sensing 10 100 net work device on the other If a 100Base network device is on one side of the Model 2312M there...

Page 8: ...dard straight through network patch cable To connect the 2300M models to a terminal transceiver or network inter face card NIC set the switch to the MDI X lefthand position see Figure 1 Otherwise to c...

Page 9: ...grams in Figure 2 reflect the pinouts of the Ethernet RJ 45 jack when switched to MDI and MDI X settings Note Twisted pair connections from the Ethernet RJ 45 Jack to the network device should be 802...

Page 10: ...Series Media Converter and other network devices must not exceed 2 km 1 24 miles 298 7 m 980 ft in 100Base SX mode Model 2311M only Figure 3 Fiber connector locations 4 Connect the DC power output si...

Page 11: ...e 4 shows an end to end connection between a personal computer terminal and Ethernet hub using two Patton Model 2300M Series Ether net Media Converters and a multi mode fiber connection Figure 4 End t...

Page 12: ...up LED indicators located on the side of the Model 2300M Series unit will illuminate to indicate the operating status of the unit Figure 5 Location of 2300M Series LED indicators Move fiber connector...

Page 13: ...to show activity on the fiber optic side of the unit 4 FO10 Illuminates green to show that a 10 Mbps signal is present on the fiber optic side of the unit Not used on Model 2300M 5 TP100 Illuminates...

Page 14: ...Mbps A 3 TRANSMISSION MODE Full or Half Duplex Operating Modes Auto sensing A 4 TWISTED PAIR COPPER CABLE TYPE Category 5 or better recommended A 5 FIBER CABLE TYPE Recommended 62 5 125 m multi mode f...

Page 15: ...e 2300M 5 s per km typical 2310M 5 s per km typical 2311M 5 s per km typical 2312M 5 s per km typical Typical Fiber Max Distance 2300M 1 24 mile 2 km 2310M 1 24 mile 2 km 2311M 1 24 mile 2 km in 10Bas...

Page 16: ...VDC output External UI AC Power Supply 100 240 VAC 50 60Hz input 5 VDC output 45 VDC 24 VDC 12 VDC A 12 PACKAGED WEIGHT Less than 1 lb 0 45 kg with power supply A 13 DIMENSIONS 3 0L x 1 8W x 0 8H in 7...

Reviews: