2.0  GENERAL INFORMATION

Thank you for your purchase of this Patton Electronics product.

This product has been thoroughly inspected and tested and is warrant-
ed for One Year parts and labor. If any questions or problems arise
during installation or use of this product, please do not hesitate to con-
tact Patton Electronics Technical Support at (301) 975-1007.

2.1  FEATURES

• Operates asynchronously, point to point or multipoint,

over 2 or 4 wires

• Up to 32 multipoint device drops in a polling environment

• Data rates to 115.2 Kbps

• Passes transmit & receive data

• Operates off 5V power supply

• Operates without “echo”

• Driver controlled as “constantly on”,  “controlled by RTS”, or

“controlled by DTR”

• Compact size ( 3.8” x 2.10” x 0.8”)

• Twisted pair connection via strain relief, RJ-11 or RJ-45

• 2500 Vrms Optical Isolation

2.2  DESCRIPTION

The Model 2086 Series High Speed RS-232 to RS-485 Interface

Converter provides exceptional versatility in a compact package. The
Model 2086 Series supports asynchronous RS-232 data rates to 115.2
Kbps over one or two unconditioned twisted pair.

The Model 2086 Series  can handle up to 32 terminal drops in a

multipoint polling environment. Carrier may be set to “constantly on” or
“controlled by RTS”, or “controlled by DTR” and the unit operates with-
out “echo”.

The Model 2086 Series is equipped with a DB-25 for the RS-232

connection. Options for twisted pair connection include RJ-11, RJ-45,
or Terminal Block. 2500Vrms optical isolators provide isolation
between the RS-232 and RS-485 interfaces.

3.0  CONFIGURATION

The Model 2086 Series is configured using a four position DIP

switch and two headers. Figure 1 (below) shows the location of the DIP
switch and the two headers on the board.

3.1 DIP SWITCH CONFIGURATION

The DIP switches control the transmit/receive signals on the Model

2086 Series. The table below shows the default configuration of the
switches. Following the default table is a chart showing the different
switch and  jumper combinations that the Model 2086 Series has to
offer. Also included in this section is a description of the switches.

+XMT- G -RCV+

ON

OFF

Figure 1. Top View of Model 2086 Series board, showing Dip switch and jumpers

A

A
B

B

DIP SWITCH

JP4

JP3

Power

DIP SWITCH DEFAULT SETTING TABLE

Position       

Function

S1

RTS Control

S2

DTR Control

S3

Reserved

S4

Transmitter Control

Default

Switch

Function

off

no RTS control

of transmitter

off

no DTR control

off

n/a

ON

Constantly ON

1

2

3

4

Summary of Contents for 2086 Series

Page 1: ...975 1000 TECHNICAL SUPPORT 301 975 1007 http www patton com Part 07M2086 C Doc 055051UC Revised 05 11 99 MODEL 2086 Series Optically Isolated RS 232 to RS 485 Interface Converter C E R T I F I E D An...

Page 2: ...ich are designed to provide reasonable protection from such interfer ence in a commercial installation However there is no guarantee that interference will not occur in a particular installation If th...

Page 3: ...nal drops in a multipoint polling environment Carrier may be set to constantly on or controlled by RTS or controlled by DTR and the unit operates with out echo The Model 2086 Series is equipped with a...

Page 4: ...Switches S1 and S4 must be OFF position when Switch S2 is ON S2 Setting On DTR Controls the Transmitter Off DTR Control is OFF Switch S3 Reserved Switch S3 is reserved for future use and must remain i...

Page 5: ...sary to use a cross over cable The diagram below shows how a cross over cable should be constructed for an environment where both the Model 2086 Series and the RS 485 device use a 6 wire RJ 11 connect...

Page 6: ...operly configured the Model 2086 Series and connected the twisted pair wires correctly simply plug the Model 2086 Series directly into the DB 25 DTE port of the RS 232 device Remember to insert and ti...

Page 7: ...n Using Terminal Blocks Most RS 485 devices employ a two wire half duplex configuration When using this configuration be sure to first set the Models 2086M 2086F to half duplex mode by switching DIP s...

Page 8: ...o 50 C Humidity 5 to 95 non condensing Size 3 8 x 2 1 x 0 8 APPENDIX B PATTON ELECTRONICS MODEL 2086 SERIES RS 232 PIN CONFIGURATIONS PATTON ELECTRONICS MODEL 2086 Series RS 485 PIN CONFIGURATIONS RJ...

Page 9: ...6MRJ45 Male RJ45 2086FRJ45 Female RJ45 2086MRJ11 Male RJ11 2086FRJ11 Female RJ11 2086M 230 Male Terminal Block 2086F 230 Female Terminal Block 2086MRJ45 230 Male RJ45 2086FRJ45 230 Female RJ45 2086MRJ...