5.0  OPERATION

Once you have configured each Model 2085RC and connected the

cables, you are ready to operate the units. Section 5.0 describes the
LED status monitors and the power-up procedure.

5.1  LED STATUS MONITORS

The Model 2085RC features front panel LEDs that indicate the con-

dition of the modem and communication link. Figure 6 (below) shows
the positions of the LEDs.

• 

The green “PWR” LED glows when power is applied to
the modem through its mid-plane chassis connection.

• 

The green “TD” and “RD” LEDs show positive state data
activity. The red “TD” and “RD” LEDs show negative state
data activity. A solid red light indicates an idle state.

• 

The green “CD” LED lights when the receive carrier is
detected; the red LED lights when the receive carrier is
absent.

5.2  POWER-UP

There is no power switch on the Model 2085RC: Power is automat-

ically applied to the 2085RC when its card-edge connector touches the
chassis’ mid-plane socket, or when the chassis’ power is turned on.

APPENDIX A

PATTON ELECTRONICS MODEL 2085RC

SPECIFICATIONS

Transmission Format:

Asynchronous

Data Rate:

0 to 115.2 Kbps

Control Signals:

DSR turns “ON” immediately after the 
terminal raises DTR; DCD turns “ON”
after recognizing the receive signal 
from the line; CTS turns on after the 
terminal raises RTS

Transmission Line:

2-wire or 4-wire, unconditioned twisted
pair

Transmit Mode:

Full or half duplex

Transmit Level:

2V ± 10% differential output voltage 

Carrier:

Constantly on or controlled by RTS 

RTS/CTS Delay:

8 msec or zero

Echo Mode:

Echo and No Echo, supported in both 
2-wire and 4-wire modes

Receiver Impedance:

Low (120 ohms), High (100k Ohms)

Line Connection:

RJ-11 or RJ-45 jack

Surge Protection:

Compliant with IEC 801.5 level 2, 
1kV

Power Supply:

Rack-mount power supply is 
switchable between 120V and 240V 
AC; rack chassis supplies 10V AC to 
the Model 2085RC, typical 
consumption is 700 mW per card

Fuse:

400mA for 120V applications; 200mA 
for 240V applications

Temperature Range:

0-50°C (32-122°F)

Altitude:

0-15,000 feet

Humidity:

Up to 95% non-condensing

Dimensions:

0.95”w x 3.1”h x 5.4”l

Figure 6. The Model 2085RC front panel, showing LED positions

Model 2085RC

Power

TD

RD

CD

TD

RD

CD

Unit

A

Unit

B

NOTE:

The 2085RC is a “hot swappable” card—it will not be

damaged by plugging it in or removing it while the rack is pow-
ered up.

Summary of Contents for 2085RC

Page 1: ...RS 232 to RS 485 Converter Dual Port Rack Mount Card SALES OFFICE 301 975 1000 TECHNICAL SUPPORT 301 975 1007 http www patton com Part 07M2085RC B Doc 047052UB Revised 05 11 99 C E R T I F I E D An IS...

Page 2: ...ges arising from the use of or inability to use this product Patton Electronics specifically disclaims all other warranties expressed or implied and the installation or use of this product shall be de...

Page 3: ...evice drops in a polling environ ment Passes transmit receive data one control signal each direction Variable high low impedance settings Carrier can be set as constantly on or controlled by RTS Able...

Page 4: ...criptions of each switch s function SWITCH SET S1 DIP switch S1 is used to configure receive impedance RTS CTS delay carrier control operation and echo enable disable The summary table below shows the...

Page 5: ...Modes Switches S2 3 and S2 4 are set together to determine whether the Model 2085RC is in 2 wire or 4 wire operating mode Note 2 wire mode is half duplex only S1 2 S1 3 Setting On On 2 wire mode Off...

Page 6: ...ch S4 is used to configure transmit impedance and 2 wire 4 wire operations The summary table below shows the factory default settings for switch S4 Following the summary table is a detailed descriptio...

Page 7: ...e In the connected closed position the strap links RJ 11 pins 1 and 6 RJ 45 pins 2 and 7 to frame ground These pins can be used as connections for the twisted pair cable shield In the open disconnecte...

Page 8: ...000R16 RACK CHASSIS The Model 1000R16 Rack Chassis Figure 5 has card slots plus its own power supply Measuring only 3 5 high the Model 1000R16 is designed to occupy only 2U in a 19 rack Sturdy front h...

Page 9: ...RC is wired as a DCE Data Communications Equipment Therefore it wants to connect to a DTE Data Termination Equipment If your RS 232 output device is a DTE you may need to use a special cable such as a...

Page 10: ...ire SIGNAL PIN PIN SIGNAL XMT 3 3 XMT XMT 4 4 XMT RJ 45 Cable 2 Wire SIGNAL PIN PIN SIGNAL XMT 4 4 XMT XMT 5 5 XMT Connection to ground is optional 4 4 2 MULTIPOINT TWISTED PAIR CONNECTION The Model 2...

Page 11: ...rmat Asynchronous Data Rate 0 to 115 2 Kbps Control Signals DSR turns ON immediately after the terminal raises DTR DCD turns ON after recognizing the receive signal from the line CTS turns on after th...

Page 12: ...distance table as a general guideline only APPENDIX C PATTON ELECTRONICS MODEL 2085RC FACTORY REPLACEMENT PARTS The Patton Model 2085RC rack system features interchangeable rear half cards power cords...

Page 13: ...ire RJ 45 Contact Number Circuit Description 1 N A Not Used 2 125 DSR 3 109 Received Line Signal Indicator CD 4 108 2 DTE Ready DTR 5 102 Signal Common 6 104 Received Data 7 103 Transmitted Data 8 106...

Reviews: