background image

APPENDIX A

PATTON ELECTRONICS MODEL 2084

SPECIFICATIONS

Transmission Format:

Asynchronous

Data Rate:

Up to 115,200 bps

Range:

Up to 4000 feet @ 9600 bps

RS-232 Interface:

DB-25

RS-485 Interface Options:

RJ-11 or RJ-45 jack; terminal block

with strain relief

Transmit Line:

2 wire unconditioned twisted pair

Transmit Mode: 

2-wire half duplex

Surge Protection:  

600W power dissipation at 1 mS 

Power:

Draws operating power from RS-
232 data and control signals; no

AC 

power or batteries required.

Temperature:  

0 to 50º C 

Humidity:

5 to 95%, non-condensing

Size:

2.66” x 2.10” x 0.73”

11

APPENDIX B

PATTON ELCTRONICS MODEL 2084 RS-232 PIN

CONFIGURATIONS

Copyright © 1998

Patton Electronics Company

All Rights Reserved

12

1- (FG) Frame Ground
2- (TD) Transmit Data

To Model 2084

3- (RD) Receive Data

From Model 2084

4- (RTS) Request to Send

To Model 2084

5- (CTS) Clear to Send

From Model 2084

6- (DSR) Data Set Ready

From Model 2084 

7- (SG) Signal Ground
8- (DCD) Data Carrier Detect

From Model 2084

To Model 2084

Data Term. Ready (DTR) - 20

DIRECTION

“DCE” ORIENTATION

DIRECTION

Summary of Contents for 2084

Page 1: ...L SALES OFFICE 301 975 1000 TECHNICAL SUPPORT 301 975 1007 http www patton com Part 07M2084 B Doc 047061UB Revised 01 26 99 MODEL 2084 High Speed RS 232 to RS 485 Interface Converter C E R T I F I E D...

Page 2: ...ules which are designed to provide reasonable protection from such interference in a commercial installation However there is no guarantee that interference will not occur in a particular installation...

Page 3: ...32 to RS 485 Interface Converter provides exceptional versatility in a compact package Requiring no AC power or batteries for operation the Model 2084 supports asynchronous RS 485 data rates to 115 2...

Page 4: ...gauges may limit distance somewhat For your convenience the Model 2084 is available with several different physical interfaces on the RS 485 side RJ 11 jack RJ 45 jack and terminal blocks with strain...

Page 5: ...to connect one pair of bare wires to the Model 2084 you will need to open the case to access the terminal blocks The following instructions will tell you how to open the case connect the bare wires t...

Page 6: ...ess in the case 8 BEND the top half of the case as necessary to place it over the strain relief assembly Do not snap the case together yet 9 Insert one captive screw through a saddle washer and then i...

Page 7: ...om RS 232 data and control signals no AC power or batteries required Temperature 0 to 50 C Humidity 5 to 95 non condensing Size 2 66 x 2 10 x 0 73 11 APPENDIX B PATTON ELCTRONICS MODEL 2084 RS 232 PIN...