background image

2.0  GENERAL INFORMATION

Thank you for your purchase of this Patton Electronics product.

This product has been thoroughly inspected and tested and is
warranted for One Year parts and labor.  If any questions or problems
arise during installation or use of this product, please do not hesitate to
contact Patton Electronics Technical Suppor at (301) 975-1007.

2.1  FEATURES

•  Converts parallel data to serial data and vice versa
•  Automatically selects parallel-to-serial and serial-to-parallel

operation

•  Serial data rates to 115.2 Kbps
•  No AC power required
•  Supports both software and hardware flow control
•  A five-state LED monitors status and diagnostics
•  Ultra-miniature size
•  A DB-9 female and a Centronics male connector
•  Made in USA

2.2  DESCRIPTION

The Patton Model 2039 Parallel to Serial Converter

automatically converts RS-232C serial data to parallel data format and
vice versa.  Incorporating advanced microprocessor technology, the
Model 2039 is able to automatically sense and select parallel and serial
modes.  The Model 2039 requires no AC power or batteries and
supports serial data rates to 115.2 Kbps.

For easy configuration, the Model 2039 features a convenient set

of external configuration switches.  These accessible configuration
switches allow the user to control baud rate, parity, word length and
flow control.  An easy-to-read LED indicator displays status and
operating condition.

Housed in an ultra-miniature ABS plastic case, the Model 2039

measures only 2.68" x 1.25" x .75".  The Patton Model 2039 comes
equipped with a DB-9 female connector on the serial side and a
Centronics 36 pin male connector on the parallel side.  A six foot
integral cable is also included.

3

3.0  CONFIGURATION

The Model 2039 is simple to install and designed for excellent

reliability  The following instructions will help you set up and install the
converter properly.  If you have any questions, please call Patton
Technical Support at (301) 975-1007.

3.1  CONFIGURATION SWITCHES

The Model 2039 uses a set of eight external DIP switches (see

Figure 1) that allow configuration to a wide range of applications.
Because all eight switches are in one externally accessible DIP switch
package, there is no need to open the case for configuration.  The
configuration switches allow you to select data rates, parity, word length
and flow control selection.  The following section describes all switch
locations, positions and functions.

The Model 2039 uses a 

miniature configuration switch package.

To configure your unit, use a small screwdriver and gently push each
switch to its proper setting.  The ON and OFF positions are shown in
Figure 2.  Default settings for the DIP switches are shown in the table
on the following page.  Detailed settings follow the table.

4

Figure 1. 

The location of the configuration switches

Figure 2. 

The miniature configuration switch package

OFF

1 2 3 4 5 6 7 8

DHS-8

Configuration

Switch

Summary of Contents for 2039

Page 1: ...allel to Serial Serial to Parallel Interface Converter SALES OFFICE 301 975 1000 TECHNICAL SUPPORT 301 975 1007 http www patton com Part 07M2039 B Doc 102081U Rev C Revised 1 23 08 C E R T I F I E D An ISO 9001 Certified Company ...

Page 2: ......

Page 3: ...container This number may be obtained from Patton Electronics Technical Support 301 975 1007 http www patton com or support patton com NOTE Packages received without an RMA number will not be accepted Patton Electronics technical staff is also available to answer any questions that might arise concerning the installation or use of your Model 2039 Technical Support hours 8AM to 5PM EST Monday throu...

Page 4: ......

Page 5: ...no need to open the case for configuration The configuration switches allow you to select data rates parity word length and flow control selection The following section describes all switch locations positions and functions The Model 2039 uses a miniature configuration switch package To configure your unit use a small screwdriver and gently push each switch to its proper setting The ON and OFF pos...

Page 6: ......

Page 7: ...e the frequency and data rate The following chart shows the settings that may be used 6 1 200 OFF OFF ON 2 400 ON OFF ON 4 800 ON ON OFF 9 600 OFF ON ON 19 200 ON ON ON 38 400 OFF OFF OFF 57 600 ON OFF OFF 115 200 OFF ON OFF Model 2039 Data Rate SW6 SW7 SW8 7B EP 1S ON ON ON 7B OP 1S OFF ON ON 7B NP 2S ON OFF ON 7B EP 2S OFF OFF ON 7B OP 2S ON ON OFF 8B EP 1S OFF ON OFF 8B OP 1S ON OFF OFF 8B NP 1...

Page 8: ......

Page 9: ...ssion line Figure 1 shows the location of the LED The following chart describes the LED s various functions The red LED indicator blinks to show data activity However since there is only one indicator it uses different LED codes to demonstrate various messages The following chart describes these codes 8 LED Codes Computer is sending data Serial device is connected computer is not sending data Both...

Page 10: ......

Page 11: ...nowledge Input normally high goes low to shift next byte out of buffer 11 Busy Input normally low goes high when buffer is full goes low when buffer empties 16 Ground 17 Ground 18 Ground 19 Ground 30 Ground 33 Ground 36 Ground DB 9 SERIAL PORT CONNECTIONS Pin Name Description 1 DCD Carrier Detect 2 RXD Receive Data 3 TXD Transmit Data power source 4 DTR Data Terminal Ready power source 5 GND Signa...

Page 12: ......

Page 13: ......

Page 14: ......

Page 15: ......

Page 16: ...tton com Support E mail support patton com Phone Sales 301 975 1000 Phone Support 301 975 1007 Fax 301 869 9293 Mail Patton Electronics Company 7622 Rickenbacker Drive Gaithersburg MD 20879 USA We are committed to a quality product at a quality price Patton Electronics is ISO 9001 certified We meet and exceed the highest standards in the industry CE UL etc It is our business to serve you If you ar...

Reviews: